Part Number Hot Search : 
0F401 405DH3 SP300 UF1002 2SK36 NL8060 EMK31 0F401
Product Description
Full Text Search
 

To Download EP2S30XXX Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Section I. Stratix II Device Family Data Sheet
This section provides designers with the data sheet specifications for Stratix(R) II devices. They contain feature definitions of the internal architecture, configuration and JTAG boundary-scan testing information, DC operating conditions, AC timing parameters, a reference to power consumption, and ordering information for Stratix II devices. This section contains the following chapters:

Chapter 1. Introduction Chapter 2. Stratix II Architecture Chapter 3. Configuration & Testing Chapter 4. Hot Socketing, ESD & Power-On Reset Chapter 5. DC & Switching Characteristics Chapter 6. Reference & Ordering Information
Revision History
Chapter
1
The table below shows the revision history for Chapters 1 through 6.
Date / Version
March 2005, 2.1 January 2005, v2.0 October 2004, v1.2 July 2004, v1.1 Added note to Table 1-2.
Changes Made
Updated "Introduction" and "Features" sections.
Updated Tables 1-2, 1-3, and 1-4.

Updated Tables 1-1 and 1-2. Updated "Features" section.
February 2004, v1.0 Added document to the Stratix II Device Handbook.
www..com
Altera Corporation
Section I-1 Preliminary
www..com
Stratix II Device Family Data Sheet
Stratix II Device Handbook, Volume 1
Chapter
2
Date / Version
March 2005, 2.1 January 2005, v2.0 October 2004, v1.2 July 2004, v1.1

Changes Made
Updated "Functional Description" section. Updated Table 2-3. Updated the "MultiVolt I/O Interface" and "TriMatrix Memory" sections. Updated Tables 2-3, 2-17, and 2-19. Updated Tables 2-9, 2-16, 2-26, and 2-27. Updated note to Tables 2-9 and 2-16. Updated Tables 2-16, 2-17, 2-18, 2-19, and 2-20. Updated Figures 2-41, 2-42, and 2-57. Removed 3 from list of SERDES factor J. Updated "High-Speed Differential I/O with DPA Support" section. In "Dedicated Circuitry with DPA Support" section, removed XSBI and changed RapidIO to Parallel RapidIO.
February 2004, v1.0 Added document to the Stratix II Device Handbook. 3 January 2005, v2.1 January 2005, v2.0 July 2004, v1.1 Updated JTAG chain device limits. Updated Table 3-3.

Added "Automated Single Event Upset (SEU) Detection" section. Updated "Device Security Using Configuration Bitstream Encryption" section. Updated Figure 3-2.
February 2004, v1.0 Added document to the Stratix II Device Handbook. 4 January 2005, v2.1 January 2005, v2.0 July 2004, v1.1 Updated input rise and fall time. Updated the "Hot Socketing Feature Implementation in Stratix II Devices", "ESD Protection", and "Power-On Reset Circuitry" sections.

Updated all tables. Added tables.
February 2004, v1.0 Added document to the Stratix II Device Handbook.
Section I-2 Preliminary
Altera Corporation
Chapter
5
Date / Version
March 2005, v2.2 January 2005, v2.1 January 2005, v2.0
Changes Made
Updated tables in "Internal Timing Parameters" section. Updated input rise and fall time.

Updated the "Power Consumption" section. Added the "High-Speed I/O Specifications" and "On-Chip Termination Specifications" sections. Removed the ESD Protection Specifications section. Updated Tables 5-3 through 5-12, 5-15 through 5-17, 5-20, 5-33, 5-37, and 5-38. Updated tables in "Timing Model" section. Added Tables 5-28 and 5-29. Updated Table 5-3. Updated introduction text in the "PLL Timing Specifications" section. Re-organized chapter. Added typical values and CO U T F B to Table 5-30. Added undershoot specification to Note (4) for Tables 5-1 through 5-9. Added Note (1) to Tables 5-5 and 5-6. Added VI D and VI C M to Table 5-10. Added "I/O Timing Measurement Methodology" section. Added Table 5-69. Updated Tables 5-1 through 5-2 and Tables 5-22 through 5-27.
October 2004, v1.2 July 2004, v1.1

February 2004, v1.0 Added document to the Stratix II Device Handbook. 6 January 2005, v2.0 October 2004, v1.1 Contact information was removed. Updated Figure 6-1.
February 2004, v1.0 Added document to the Stratix II Device Handbook.
Altera Corporation
1-3 Stratix II Device Handbook, Volume 1
Stratix II Device Family Data Sheet
1-4 Stratix II Device Handbook, Volume 1
Altera Corporation
1. Introduction
SII51001-2.1
Introduction
The Stratix(R) II FPGA family is based on a 1.2-V, 90-nm, all-layer copper SRAM process and features a new logic structure that maximizes performance, and enables device densities approaching 180,000 equivalent logic elements (LEs). Stratix II devices offer up to 9 Mbits of on-chip, TriMatrixTM memory for demanding, memory intensive applications and has up to 96 DSP blocks with up to 384 (18-bit x 18-bit) multipliers for efficient implementation of high performance filters and other DSP functions. Various high-speed external memory interfaces are supported, including double data rate (DDR) SDRAM and DDR2 SDRAM, RLDRAM II, quad data rate (QDR) II SRAM, and single data rate (SDR) SDRAM. Stratix II devices support various I/O standards along with support for 1-gigabit per second (Gbps) source synchronous signaling with DPA circuitry. Stratix II devices offer a complete clock management solution with internal clock frequency of up to 550 MHz and up to 12 phase-locked loops (PLLs). Stratix II devices are also the industry's first FPGAs with the ability to decrypt a configuration bitstream using the Advanced Encryption Standard (AES) algorithm to protect designs. The Stratix II family offers the following features:

Features


15,600 to 179,400 equivalent LEs; see Table 1-1 New and innovative adaptive logic module (ALM), the basic building block of the Stratix II architecture, maximizes performance and resource usage efficiency Up to 9,383,040 RAM bits (1,172,880 bytes) available without reducing logic resources TriMatrix memory consisting of three RAM block sizes to implement true dual-port memory and first-in first-out (FIFO) buffers High-speed DSP blocks provide dedicated implementation of multipliers (at up to 450 MHz), multiply-accumulate functions, and finite impulse response (FIR) filters Up to 16 global clocks with 24 clocking resources per device region Clock control block supports dynamic clock network enable/disable, which allows clock networks to power down to reduce power consumption in user mode Up to 12 PLLs (four enhanced PLLs and eight fast PLLs) per device provide spread spectrum, programmable bandwidth, clock switchover, real-time PLL reconfiguration, and advanced multiplication and phase shifting
Altera Corporation March 2005
1-1
Features



Support for numerous single-ended and differential I/O standards High-speed differential I/O support on up to 156 channels with DPA circuitry for 1-Gbps performance Support for high-speed networking and communications bus standards including Parallel RapidIO, SPI-4 Phase 2 (POS-PHY Level 4), HyperTransportTM technology, and SFI-4 Support for high-speed external memory, including DDR and DDR2 SDRAM, RLDRAM II, QDR II SRAM, and SDR SDRAM Support for multiple intellectual property megafunctions from Altera MegaCore(R) functions and Altera Megafunction Partners Program (AMPPSM) megafunctions Support for design security using configuration bitstream encryption Support for remote configuration updates
Table 1-1. Stratix II FPGA Family Features Feature
ALMs Adaptive look-up tables (ALUTs) (1) Equivalent LEs (2) M512 RAM blocks M4K RAM blocks M-RAM blocks Total RAM bits DSP blocks 18-bit x 18-bit multipliers (3) Enhanced PLLs Fast PLLs Maximum user I/O pins Notes to Table 1-1:
(1) (2) (3) One ALM contains two ALUTs. The ALUT is the cell used in the Quartus II software for logic synthesis. This is the equivalent number of LEs in a Stratix device (four-input LUT-based architecture). These multipliers are implemented using the DSP blocks.
EP2S15
6,240 12,480 15,600 104 78 0 419,328 12 48 2 4 366
EP2S30
13,552 27,104 33,880 202 144 1 1,369,728 16 64 2 4 500
EP2S60
24,176 48,352 60,440 329 255 2 2,544,192 36 144 4 8 718
EP2S90
36,384 72,768 90,960 488 408 4 4,520,488 48 192 4 8 902
EP2S130
53,016 106,032 132,540 699 609 6 6,747,840 63 252 4 8 1,126
EP2S180
71,760 143,520 179,400 930 768 9 9,383,040 96 384 4 8 1,170
1-2 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Introduction
Stratix II devices are available in space-saving FineLine BGA(R) packages (see Tables 1-2 and 1-3). All Stratix II devices support vertical migration within the same package (for example, the designer can migrate between the EP2S15, EP2S30, and EP2S60 devices in the 672-pin FineLine BGA package). Vertical migration means that designers can migrate to devices whose dedicated pins, configuration pins, and power pins are the same for a given package across device densities. For I/O pin migration across densities, the designer must cross reference the available I/O pins using the device pin-outs for all planned densities of a given package type to identify which I/O pins are migratable.
Table 1-2. Stratix II Package Options & I/O Pin Counts 484-Pin FineLine BGA
342 342 334 308 (4)
Notes (1), (2) 780-Pin FineLine BGA 1,020-Pin FineLine BGA 1,508-Pin FineLine BGA
Device
484-Pin Hybrid FineLine BGA
672-Pin FineLine BGA
366 500 492
EP2S15 EP2S30 EP2S60 (3) EP2S90 (3) EP2S130 (3) EP2S180 (3) Notes to Table 1-2:
(1) (2) (3)
718 534 (4) 534 (4) 758 742 742 902 1,126 1,170
(4)
All I/O pin counts include eight dedicated clock input pins (clk1p, clk1n, clk3p, clk3n, clk9p, clk9n, clk11p, and clk11n) that can be used for data inputs. The Quartus II software I/O pin counts include one additional pin, PLL_ENA, which is not available as a generalpurpose I/O pin. The PLL_ENA pin can only be used to enable the PLLs within the device. The I/O pin counts for the EP2S60, EP2S90, EP2S130, and EP2S180 devices in the 1020-pin and 1508-pin packages include eight dedicated fast PLL clock inputs (FPLL7CLKp/n, FPLL8CLKp/n, FPLL9CLKp/n, and FPLL10CLKp/n) that can be used for data inputs. The I/O count for this package is preliminary and is subject to change.
Table 1-3. Stratix II FineLine BGA Package Sizes Dimension
Pitch (mm) Area (mm2) Length x width (mm x mm)
484 Pin
1.00 529 23 x 23
484-Pin Hybrid
1.00 729 27 x 27
672 Pin
1.00 729 27 x 27
780 Pin
1.00 841 29 x 29
1,020 Pin
1.00 1,089 33 x 33
1,508 Pin
1.00 1,600 40 x 40
Altera Corporation March 2005
1-3 Stratix II Device Handbook, Volume 1
Features
Stratix II devices are available in up to three speed grades, -3, -4, and -5, with -3 being the fastest. Table 1-4 shows Stratix II device speed-grade offerings.
Table 1-4. Stratix II Device Speed Grades Device
EP2S15 EP2S30 EP2S60 EP2S90 EP2S130 EP2S180
484-Pin FineLine BGA
-3, -4, -5 -3, -4, -5 -3, -4, -5
484-Pin 672-Pin 780-Pin 1,020-Pin 1,508-Pin Hybrid FineLine BGA FineLine BGA FineLine BGA FineLine BGA FineLine BGA
-3, -4, -5 -3, -4, -5 -3, -4, -5 -4, -5 -4, -5 -4, -5 -3, -4, -5 -3, -4, -5 -4, -5 -4, -5 -3, -4, -5 -4, -5 -4, -5
1-4 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
2. Stratix II Architecture
SII51002-2.1
Functional Description
Stratix(R) II devices contain a two-dimensional row- and column-based architecture to implement custom logic. A series of column and row interconnects of varying length and speed provides signal interconnects between logic array blocks (LABs), memory block structures (M512 RAM, M4K RAM, and M-RAM blocks), and digital signal processing (DSP) blocks. Each LAB consists of eight adaptive logic modules (ALMs). An ALM is the Stratix II device family's basic building block of logic providing efficient implementation of user logic functions. LABs are grouped into rows and columns across the device. M512 RAM blocks are simple dual-port memory blocks with 512 bits plus parity (576 bits). These blocks provide dedicated simple dual-port or single-port memory up to 18-bits wide at up to 500 MHz. M512 blocks are grouped into columns across the device in between certain LABs. M4K RAM blocks are true dual-port memory blocks with 4K bits plus parity (4,608 bits). These blocks provide dedicated true dual-port, simple dual-port, or single-port memory up to 36-bits wide at up to 550 MHz. These blocks are grouped into columns across the device in between certain LABs. M-RAM blocks are true dual-port memory blocks with 512K bits plus parity (589,824 bits). These blocks provide dedicated true dual-port, simple dual-port, or single-port memory up to 144-bits wide at up to 400 MHz. Several M-RAM blocks are located individually in the device's logic array. DSP blocks can implement up to either eight full-precision 9 x 9-bit multipliers, four full-precision 18 x 18-bit multipliers, or one full-precision 36 x 36-bit multiplier with add or subtract features. The DSP blocks support Q1.15 format rounding and saturation in the multiplier and accumulator stages. These blocks also contain shift registers for digital signal processing applications, including finite impulse response (FIR) and infinite impulse response (IIR) filters. DSP blocks are grouped into columns across the device. Each Stratix II device I/O pin is fed by an I/O element (IOE) located at the end of LAB rows and columns around the periphery of the device. I/O pins support numerous single-ended and differential I/O standards.
Altera Corporation March 2005
2-1
Functional Description
Each IOE contains a bidirectional I/O buffer and six registers for registering input, output, and output-enable signals. When used with dedicated clocks, these registers provide exceptional performance and interface support with external memory devices such as DDR and DDR2 SDRAM, RLDRAM II, and QDR II SRAM devices. High-speed serial interface channels with dynamic phase alignment (DPA) support data transfer at up to 1 Gbps using LVDS or HyperTransportTM technology I/O standards. Figure 2-1 shows an overview of the Stratix II device. Figure 2-1. Stratix II Block Diagram
M512 RAM Blocks for Dual-Port Memory, Shift Registers, & FIFO Buffers M4K RAM Blocks DSP Blocks for for True Dual-Port Multiplication and Full Memory & Other Embedded Implementation of FIR Filters Memory Functions IOEs Support DDR, PCI, PCI-X, SSTL-3, SSTL-2, HSTL-1, HSTL-2, LVDS, HyperTransport & other I/O Standards
IOEs IOEs IOEs IOEs IOEs IOEs IOEs IOEs IOEs IOEs IOEs IOEs IOEs IOEs IOEs IOEs IOEs IOEs
LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs
IOEs
LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs
IOEs
LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs LABs
IOEs
LABs LABs LABs LABs LABs
M-RAM Block
LABs LABs LABs
DSP Block
2-2 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
The number of M512 RAM, M4K RAM, and DSP blocks varies by device along with row and column numbers and M-RAM blocks. Table 2-1 lists the resources available in Stratix II devices.
Table 2-1. Stratix II Device Resources Device
EP2S15 EP2S30 EP2S60 EP2S90 EP2S130 EP2S180
M512 RAM Columns/Blocks
4 / 104 6 / 202 7 / 329 8 / 488 9 / 699 11 / 930
M4K RAM Columns/Blocks
3 / 78 4 / 144 5 / 255 6 / 408 7 / 609 8 / 768
M-RAM Blocks
0 1 2 4 6 9
DSP Block Columns/Blocks
2 / 12 2 / 16 3 / 36 3 / 48 3 / 63 4 / 96
LAB Columns
30 49 62 71 81 100
LAB Rows
26 36 51 68 87 96
Logic Array Blocks
Each LAB consists of eight ALMs, carry chains, shared arithmetic chains, LAB control signals, local interconnect, and register chain connection lines. The local interconnect transfers signals between ALMs in the same LAB. Register chain connections transfer the output of an ALM register to the adjacent ALM register in an LAB. The Quartus(R) II Compiler places associated logic in an LAB or adjacent LABs, allowing the use of local, shared arithmetic chain, and register chain connections for performance and area efficiency. Figure 2-2 shows the Stratix II LAB structure.
Altera Corporation March 2005
2-3 Stratix II Device Handbook, Volume 1
Logic Array Blocks
Figure 2-2. Stratix II LAB Structure
Row Interconnects of Variable Speed & Length
ALMs
Direct link interconnect from adjacent block Direct link interconnect from adjacent block
Direct link interconnect to adjacent block
Direct link interconnect to adjacent block
Local Interconnect
LAB
Local Interconnect is Driven from Either Side by Columns & LABs, & from Above by Rows
Column Interconnects of Variable Speed & Length
LAB Interconnects
The LAB local interconnect can drive ALMs in the same LAB. It is driven by column and row interconnects and ALM outputs in the same LAB. Neighboring LABs, M512 RAM blocks, M4K RAM blocks, M-RAM blocks, or DSP blocks from the left and right can also drive an LAB's local interconnect through the direct link connection. The direct link connection feature minimizes the use of row and column interconnects, providing higher performance and flexibility. Each ALM can drive 24 ALMs through fast local and direct link interconnects. Figure 2-3 shows the direct link connection.
2-4 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-3. Direct Link Connection
Direct link interconnect from left LAB, TriMatrix memory block, DSP block, or IOE output Direct link interconnect from right LAB, TriMatrix memory block, DSP block, or IOE output
ALMs
Direct link interconnect to left
Direct link interconnect to right
Local Interconnect
LAB Control Signals
Each LAB contains dedicated logic for driving control signals to its ALMs. The control signals include three clocks, three clock enables, two asynchronous clears, synchronous clear, asynchronous preset/load, and synchronous load control signals. This gives a maximum of 11 control signals at a time. Although synchronous load and clear signals are generally used when implementing counters, they can also be used with other functions. Each LAB can use three clocks and three clock enable signals. However, there can only be up to two unique clocks per LAB, as shown in the LAB control signal generation circuit in Figure 2-4. Each LAB's clock and clock enable signals are linked. For example, any ALM in a particular LAB using the labclk1 signal will also use labclkena1. If the LAB uses both the rising and falling edges of a clock, it also uses two LAB-wide clock signals. De-asserting the clock enable signal will turn off the corresponding LAB-wide clock. Each LAB can use two asynchronous clear signals and an asynchronous load/preset signal. The asynchronous load acts as a preset when the asynchronous load data input is tied high. When the asynchronous load/preset signal is used, the labclkena0 signal is no longer available.
Altera Corporation March 2005
2-5 Stratix II Device Handbook, Volume 1
Adaptive Logic Modules
The LAB row clocks [5..0] and LAB local interconnect generate the LAB-wide control signals. The MultiTrackTM interconnect's inherent low skew allows clock and control signal distribution in addition to data. Figure 2-4 shows the LAB control signal generation circuit. Figure 2-4. LAB-Wide Control Signals
There are two unique clock signals per LAB.
6 Dedicated Row LAB Clocks 6
6
Local Interconnect
Local Interconnect
Local Interconnect
Local Interconnect
Local Interconnect
Local Interconnect
labclk0 labclkena0 or asyncload or labpreset
labclk1 labclkena1
labclk2 labclkena2
syncload labclr0
labclr1 synclr
Adaptive Logic Modules
The basic building block of logic in the Stratix II architecture, the adaptive logic module (ALM), provides advanced features with efficient logic utilization. Each ALM contains a variety of look-up table (LUT)-based resources that can be divided between two adaptive LUTs (ALUTs). With up to eight inputs to the two ALUTs, one ALM can implement various combinations of two functions. This adaptability allows the ALM to be completely backward-compatible with four-input LUT architectures. One ALM can also implement any function of up to six inputs and certain seven-input functions.
2-6 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
In addition to the adaptive LUT-based resources, each ALM contains two programmable registers, two dedicated full adders, a carry chain, a shared arithmetic chain, and a register chain. Through these dedicated resources, the ALM can efficiently implement various arithmetic functions and shift registers. Each ALM drives all types of interconnects: local, row, column, carry chain, shared arithmetic chain, register chain, and direct link interconnects. Figure 2-5 shows a high-level block diagram of the Stratix II ALM while Figure 2-6 shows a detailed view of all the connections in the ALM. Figure 2-5. High-Level Block Diagram of the Stratix II ALM
carry_in shared_arith_in reg_chain_in To general or local routing adder0
D Q
dataf0 datae0 dataa datab datac datad datae1 dataf1 reg1 Combinational Logic adder1
D Q
To general or local routing
reg0
To general or local routing
To general or local routing carry_out shared_arith_out reg_chain_out
Altera Corporation March 2005
2-7 Stratix II Device Handbook, Volume 1
shared_arith_in carry_in syncload ena[2..0]
Adaptive Logic Modules
reg_chain_in sclr asyncload
Local Interconnect
dataf0
Figure 2-6. Stratix II ALM Details
2-8 Stratix II Device Handbook, Volume 1
4-Input LUT Row, column & direct link routing
ENA CLRN PRN/ALD D Q ADATA
Local Interconnect
datae0
Local Interconnect 3-Input LUT
datac
Row, column & direct link routing Local Interconnect
Local Interconnect 3-Input LUT
dataa
Local Interconnect 4-Input LUT
datab
Local Interconnect
datad 3-Input LUT
PRN/ALD D Q ADATA ENA CLRN
Row, column & direct link routing Row, column & direct link routing Local Interconnect
3-Input LUT VCC
Local Interconnect
datae1
Local Interconnect
dataf1
carry_out shared_arith_out
reg_chain_out
clk[2..0] aclr[1..0]
Altera Corporation March 2005
Stratix II Architecture
One ALM contains two programmable registers. Each register has data, clock, clock enable, synchronous and asynchronous clear, asynchronous load data, and synchronous and asynchronous load/preset inputs. Global signals, general-purpose I/O pins, or any internal logic can drive the register's clock and clear control signals. Either general-purpose I/O pins or internal logic can drive the clock enable, preset, asynchronous load, and asynchronous load data. The asynchronous load data input comes from the datae or dataf input of the ALM, which are the same inputs that can be used for register packing. For combinational functions, the register is bypassed and the output of the LUT drives directly to the outputs of the ALM. Each ALM has two sets of outputs that drive the local, row, and column routing resources. The LUT, adder, or register output can drive these output drivers independently (see Figure 2-6). For each set of output drivers, two ALM outputs can drive column, row, or direct link routing connections, and one of these ALM outputs can also drive local interconnect resources. This allows the LUT or adder to drive one output while the register drives another output. This feature, called register packing, improves device utilization because the device can use the register and the combinational logic for unrelated functions. Another special packing mode allows the register output to feed back into the LUT of the same ALM so that the register is packed with its own fan-out LUT. This provides another mechanism for improved fitting. The ALM can also drive out registered and unregistered versions of the LUT or adder output. See the Performance & Logic Efficiency Analysis of Stratix II Devices White Paper for more information on the efficiencies of the Stratix II ALM and comparisons with previous architectures.
ALM Operating Modes
The Stratix II ALM can operate in one of the following modes:

Normal mode Extended LUT mode Arithmetic mode Shared arithmetic mode
Each mode uses ALM resources differently. In each mode, eleven available inputs to the ALM--the eight data inputs from the LAB local interconnect; carry-in from the previous ALM or LAB; the shared arithmetic chain connection from the previous ALM or LAB; and the register chain connection--are directed to different destinations to implement the desired logic function. LAB-wide signals provide clock, asynchronous clear, asynchronous preset/load, synchronous clear,
Altera Corporation March 2005
2-9 Stratix II Device Handbook, Volume 1
Adaptive Logic Modules
synchronous load, and clock enable control for the register. These LABwide signals are available in all ALM modes. See the "LAB Control Signals" section for more information on the LAB-wide control signals. The Quartus II software and supported third-party synthesis tools, in conjunction with parameterized functions such as library of parameterized modules (LPM) functions, automatically choose the appropriate mode for common functions such as counters, adders, subtractors, and arithmetic functions. If required, the designer can also create special-purpose functions that specify which ALM operating mode to use for optimal performance.
Normal Mode
The normal mode is suitable for general logic applications and combinational functions. In this mode, up to eight data inputs from the LAB local interconnect are inputs to the combinational logic. The normal mode allows two functions to be implemented in one Stratix II ALM, or an ALM to implement a single function of up to six inputs. The ALM can support certain combinations of completely independent functions and various combinations of functions which have common inputs. Figure 2-7 shows the supported LUT combinations in normal mode.
2-10 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-7. ALM in Normal Mode Note (1)
dataf0 datae0 datac dataa datab datad datae1 dataf1
4-Input LUT
combout0
dataf0 datae0 datac dataa datab
5-Input LUT
combout0
4-Input LUT
combout1 datad datae1 dataf1
5-Input LUT
combout1
dataf0 datae0 datac dataa datab
5-Input LUT
combout0
datad datae1 dataf1
dataf0 datae0 dataa datab datac datad
6-Input LUT
combout0
3-Input LUT
combout1
dataf0 datae0 datac dataa datab
5-Input LUT
combout0
dataf0 datae0 dataa datab datac datad
6-Input LUT
combout0
datad datae1 dataf1
4-Input LUT
combout1
datae1 dataf1
6-Input LUT
combout1
Note to Figure 2-7:
(1) Combinations of functions with less inputs than those shown are also supported. For example, combinations of functions with the following number of inputs are supported: 4 and 3, 3 and 3, 3 and 2, 5 and 2, etc.
The normal mode provides complete backward compatibility with fourinput LUT architectures. Two independent functions of four inputs or less can be implemented in one Stratix II ALM. In addition, a five-input function and an independent three-input function can be implemented without sharing inputs.
Altera Corporation March 2005
2-11 Stratix II Device Handbook, Volume 1
Adaptive Logic Modules
For the packing of two five-input functions into one ALM, the functions must have at least two common inputs. The common inputs are dataa and datab. The combination of a four-input function with a five-input function requires one common input (either dataa or datab). In the case of implementing two six-input functions in one ALM, four inputs must be shared and the combinational function must be the same. For example, a 4 x 2 crossbar switch (two 4-to-1 multiplexers with common inputs and unique select lines) can be implemented in one ALM, as shown in Figure 2-8. The shared inputs are dataa, datab, datac, and datad, while the unique select lines are datae0 and dataf0 for function0, and datae1 and dataf1 for function1. This crossbar switch consumes four LUTs in a four-input LUT-based architecture. Figure 2-8. 4 x 2 Crossbar Switch Example
4 x 2 Crossbar Switch sel0[1..0] inputa inputb inputc inputd out1 sel1[1..0] datae1 dataf1 Six-Input LUT (Function1) out0 dataf0 datae0 dataa datab datac datad Implementation in 1 ALM
Six-Input LUT (Function0)
combout0
combout1
In a sparsely used device, functions that could be placed into one ALM may be implemented in separate ALMs. The Quartus II Compiler will spread a design out to achieve the best possible performance. As a device begins to fill up, the Quartus II software will automatically utilize the full potential of the Stratix II ALM. The Quartus II Compiler will automatically search for functions of common inputs or completely independent functions to be placed into one ALM and to make efficient use of the device resources. In addition, the designer can manually control resource usage by setting location assignments. Any six-input function can be implemented utilizing inputs dataa, datab, datac, datad, and either datae0 and dataf0 or datae1 and dataf1. If datae0 and dataf0 are utilized, the output will be driven to register0, and/or register0 is bypassed and the data drives out to the interconnect using the top set of output drivers (see Figure 2-9). If
2-12 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
datae1 and dataf1 are utilized, the output drives to register1 and/or bypasses register1 and drives to the interconnect using the bottom set of output drivers. The Quartus II Compiler automatically selects the inputs to the LUT. Asynchronous load data for the register comes from the datae or dataf input of the ALM. ALMs in normal mode support register packing. Figure 2-9. 6-Input Function in Normal Mode Notes (1), (2)
dataf0 datae0 dataa datab datac datad datae1 dataf1 (2) To general or local routing 6-Input LUT
D Q
To general or local routing
reg0
D
Q
To general or local routing
These inputs are available for register packing.
reg1
Notes to Figure 2-9:
(1) (2) If datae1 and dataf1 are used as inputs to the six-input function, then datae0 and dataf0 are available for register packing. The dataf1 input is available for register packing only if the six-input function is un-registered.
Extended LUT Mode
The extended LUT mode is used to implement a specific set of seven-input functions. The set must be a 2-to-1 multiplexer fed by two arbitrary five-input functions sharing four inputs. Figure 2-10 shows the template of supported seven-input functions utilizing extended LUT mode. In this mode, if the seven-input function is unregistered, the unused eighth input is available for register packing. Functions that fit into the template shown in Figure 2-10 occur naturally in designs. These functions often appear in designs as "if-else" statements in Verilog HDL or VHDL code.
Altera Corporation March 2005
2-13 Stratix II Device Handbook, Volume 1
Adaptive Logic Modules
Figure 2-10. Template for Supported Seven-Input Functions in Extended LUT Mode
datae0 datac dataa datab datad dataf0 5-Input LUT combout0
D Q
To general or local routing To general or local routing
5-Input LUT datae1 dataf1 (1)
reg0
This input is available for register packing.
Note to Figure 2-10:
(1) If the seven-input function is unregistered, the unused eighth input is available for register packing. The second register, reg1, is not available.
Arithmetic Mode
The arithmetic mode is ideal for implementing adders, counters, accumulators, wide parity functions, and comparators. An ALM in arithmetic mode uses two sets of two four-input LUTs along with two dedicated full adders. The dedicated adders allow the LUTs to be available to perform pre-adder logic; therefore, each adder can add the output of two four-input functions. The four LUTs share the dataa and datab inputs. As shown in Figure 2-11, the carry-in signal feeds to adder0, and the carry-out from adder0 feeds to carry-in of adder1. The carry-out from adder1 drives to adder0 of the next ALM in the LAB. ALMs in arithmetic mode can drive out registered and/or unregistered versions of the adder outputs.
2-14 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-11. ALM in Arithmetic Mode
carry_in
datae0 4-Input LUT
adder0
To general or local routing
D Q
dataf0 datac datab dataa
To general or local routing
4-Input LUT
reg0
adder1
datad datae1 4-Input LUT
D Q
To general or local routing To general or local routing
4-Input LUT dataf1 carry_out
reg1
While operating in arithmetic mode, the ALM can support simultaneous use of the adder's carry output along with combinational logic outputs. In this operation, the adder output is ignored. This usage of the adder with the combinational logic output provides resource savings of up to 50% for functions that can use this ability. An example of such functionality is a conditional operation, such as the one shown in Figure 2-12. The equation for this example is: R = (X < Y) ? Y : X To implement this function, the adder is used to subtract `Y' from `X.' If `X' is less than `Y,' the carry_out signal will be `1.' The carry_out signal is fed to an adder where it drives out to the LAB local interconnect. It then feeds to the LAB-wide syncload signal. When asserted, syncload selects the syncdata input. In this case, the data `Y' drives the syncdata inputs to the registers. If `X' is greater than or equal to `Y,' the syncload signal is de-asserted and `X' drives the data port of the registers.
Altera Corporation March 2005
2-15 Stratix II Device Handbook, Volume 1
Adaptive Logic Modules
Figure 2-12. Conditional Operation Example
Adder output is not used.
ALM 1 X[0] Y[0] Comb & Adder Logic X[0] R[0]
D Q
To general or local routing
syncdata
X[1] Y[1] Comb & Adder Logic X[1]
reg0 syncload
D
Q
R[1]
To general or local routing
reg1
Carry Chain
ALM 2 X[2] Y[2] Comb & Adder Logic
syncload
X[2]
D Q
R[2]
To general or local routing
reg0 syncload Comb & Adder Logic carry_out To local routing & then to LAB-wide syncload
The arithmetic mode also offers clock enable, counter enable, synchronous up/down control, add/subtract control, synchronous clear, synchronous load. The LAB local interconnect data inputs generate the clock enable, counter enable, synchronous up/down and add/subtract control signals. These control signals are good candidates for the inputs that are shared between the four LUTs in the ALM. The synchronous clear and synchronous load options are LAB-wide signals that affect all registers in the LAB. The Quartus II software automatically places any registers that are not used by the counter into other LABs. Carry Chain The carry chain provides a fast carry function between the dedicated adders in arithmetic or shared arithmetic mode. Carry chains can begin in either the first ALM or the fifth ALM in an LAB. The final carry-out signal is routed to an ALM, where it is fed to local, row, or column interconnects.
2-16 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
The Quartus II Compiler automatically creates carry chain logic during design processing, or the designer can create it manually during design entry. Parameterized functions such as LPM functions automatically take advantage of carry chains for the appropriate functions. The Quartus II Compiler creates carry chains longer than 16 (8 ALMs in arithmetic or shared arithmetic mode) by linking LABs together automatically. For enhanced fitting, a long carry chain runs vertically allowing fast horizontal connections to TriMatrix memory and DSP blocks. A carry chain can continue as far as a full column. To avoid routing congestion in one small area of the device when a high fan-in arithmetic function is implemented, the LAB can support carry chains that only utilize either the top half or the bottom half of the LAB before connecting to the next LAB. This leaves the other half of the ALMs in the LAB available for implementing narrower fan-in functions in normal mode. Carry chains that use the top four ALMs in the first LAB will carry into the top half of the ALMs in the next LAB within the column. Carry chains that use the bottom four ALMs in the first LAB will carry into the bottom half of the ALMs in the next LAB within the column. Every other column of LABs is top-half bypassable, while the other LAB columns are bottom-half bypassable. See the "MultiTrack Interconnect" section for more information on carry chain interconnect.
Shared Arithmetic Mode
In shared arithmetic mode, the ALM can implement a three-input add. In this mode, the ALM is configured with four 4-input LUTs. Each LUT either computes the sum of three inputs or the carry of three inputs. The output of the carry computation is fed to the next adder (either to adder1 in the same ALM or to adder0 of the next ALM in the LAB) via a dedicated connection called the shared arithmetic chain. This shared arithmetic chain can significantly improve the performance of an adder tree by reducing the number of summation stages required to implement an adder tree. Figure 2-13 shows the ALM in shared arithmetic mode.
Altera Corporation March 2005
2-17 Stratix II Device Handbook, Volume 1
Adaptive Logic Modules
Figure 2-13. ALM in Shared Arithmetic Mode
shared_arith_in carry_in
4-Input LUT
D Q
To general or local routing To general or local routing
datae0 datac datab dataa
4-Input LUT
reg0
datad datae1
4-Input LUT
D Q
To general or local routing To general or local routing
4-Input LUT
reg1
carry_out shared_arith_out
Note to Figure 2-13:
(1) Inputs dataf0 and dataf1 are available for register packing in shared arithmetic mode.
Adder trees can be found in many different applications. For example, the summation of the partial products in a logic-based multiplier can be implemented in a tree structure. Another example is a correlator function that can use a large adder tree to sum filtered data samples in a given time frame to recover or to de-spread data which was transmitted utilizing spread spectrum technology. An example of a three-bit add operation utilizing the shared arithmetic mode is shown in Figure 2-14. The partial sum (S[2..0]) and the partial carry (C[2..0]) is obtained using the LUTs, while the result (R[2..0]) is computed using the dedicated adders.
2-18 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-14. Example of a 3-bit Add Utilizing Shared Arithmetic Mode
shared_arith_in = '0' carry_in = '0' 3-Bit Add Example X2 X1 X0 Y2 Y1 Y0 + Z2 Z1 Z0 S2 S1 S0 + C2 C1 C0 R3 R2 R1 R0 X0 Y0 Z0 X1 Y1 Z1 ALM Implementation ALM 1
1st stage add is implemented in LUTs. 2nd stage add is implemented in adders.
3-Input LUT
S0 R0
3-Input LUT
C0
Binary Add 110 101 +010 001 +110 1101
Decimal Equivalents 6 5 +2 1 + 2x6 13
3-Input LUT
S1
R1 3-Input LUT ALM 2 3-Input LUT S2 R2 X2 Y2 Z2 3-Input LUT C2 C1
3-Input LUT
'0' R3
3-Input LUT
Shared Arithmetic Chain In addition to the dedicated carry chain routing, the shared arithmetic chain available in shared arithmetic mode allows the ALM to implement a three-input add. This significantly reduces the resources necessary to implement large adder trees or correlator functions. The shared arithmetic chains can begin in either the first or fifth ALM in an LAB. The Quartus II Compiler creates shared arithmetic chains longer than 16 (8 ALMs in arithmetic or shared arithmetic mode) by linking LABs together automatically. For enhanced fitting, a long shared
Altera Corporation March 2005
2-19 Stratix II Device Handbook, Volume 1
Adaptive Logic Modules
arithmetic chain runs vertically allowing fast horizontal connections to TriMatrix memory and DSP blocks. A shared arithmetic chain can continue as far as a full column. Similar to the carry chains, the shared arithmetic chains are also top- or bottom-half bypassable. This capability allows the shared arithmetic chain to cascade through half of the ALMs in a LAB while leaving the other half available for narrower fan-in functionality. Every other LAB column is top-half bypassable, while the other LAB columns are bottomhalf bypassable. See the "MultiTrack Interconnect" section for more information on shared arithmetic chain interconnect.
Register Chain
In addition to the general routing outputs, the ALMs in an LAB have register chain outputs. The register chain routing allows registers in the same LAB to be cascaded together. The register chain interconnect allows an LAB to use LUTs for a single combinational function and the registers to be used for an unrelated shift register implementation. These resources speed up connections between ALMs while saving local interconnect resources (see Figure 2-15). The Quartus II Compiler automatically takes advantage of these resources to improve utilization and performance.
2-20 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-15. Register Chain within an LAB Note (1)
From Previous ALM Within The LAB
reg_chain_in To general or local routing adder0
D Q
To general or local routing
reg0 Combinational Logic adder1
D Q
To general or local routing
reg1 To general or local routing
To general or local routing adder0
D Q
To general or local routing
reg0 Combinational Logic adder1
D Q
To general or local routing
reg1 To general or local routing
reg_chain_out
To Next ALM within the LAB
Note to Figure 2-15:
(1) The combinational or adder logic can be utilized to implement an unrelated, un-registered function.
See the "MultiTrack Interconnect" section for more information on register chain interconnect.
Altera Corporation March 2005
2-21 Stratix II Device Handbook, Volume 1
MultiTrack Interconnect
Clear & Preset Logic Control
LAB-wide signals control the logic for the register's clear and load/preset signals. The ALM directly supports an asynchronous clear and preset function. The register preset is achieved through the asynchronous load of a logic high. The direct asynchronous preset does not require a NOTgate push-back technique. Stratix II devices support simultaneous asynchronous load/preset, and clear signals. An asynchronous clear signal takes precedence if both signals are asserted simultaneously. Each LAB supports up to two clears and one load/preset signal. In addition to the clear and load/preset ports, Stratix II devices provide a device-wide reset pin (DEV_CLRn) that resets all registers in the device. An option set before compilation in the Quartus II software controls this pin. This device-wide reset overrides all other control signals.
MultiTrack Interconnect
In the Stratix II architecture, connections between ALMs, TriMatrix memory, DSP blocks, and device I/O pins are provided by the MultiTrack interconnect structure with DirectDriveTM technology. The MultiTrack interconnect consists of continuous, performance-optimized routing lines of different lengths and speeds used for inter- and intra-design block connectivity. The Quartus II Compiler automatically places critical design paths on faster interconnects to improve design performance. DirectDrive technology is a deterministic routing technology that ensures identical routing resource usage for any function regardless of placement in the device. The MultiTrack interconnect and DirectDrive technology simplify the integration stage of block-based designing by eliminating the re-optimization cycles that typically follow design changes and additions. The MultiTrack interconnect consists of row and column interconnects that span fixed distances. A routing structure with fixed length resources for all devices allows predictable and repeatable performance when migrating through different device densities. Dedicated row interconnects route signals to and from LABs, DSP blocks, and TriMatrix memory in the same row. These row resources include:

Direct link interconnects between LABs and adjacent blocks R4 interconnects traversing four blocks to the right or left R24 row interconnects for high-speed access across the length of the device
2-22 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
The direct link interconnect allows an LAB, DSP block, or TriMatrix memory block to drive into the local interconnect of its left and right neighbors and then back into itself. This provides fast communication between adjacent LABs and/or blocks without using row interconnect resources. The R4 interconnects span four LABs, three LABs and one M512 RAM block, two LABs and one M4K RAM block, or two LABs and one DSP block to the right or left of a source LAB. These resources are used for fast row connections in a four-LAB region. Every LAB has its own set of R4 interconnects to drive either left or right. Figure 2-16 shows R4 interconnect connections from an LAB. R4 interconnects can drive and be driven by DSP blocks and RAM blocks and row IOEs. For LAB interfacing, a primary LAB or LAB neighbor can drive a given R4 interconnect. For R4 interconnects that drive to the right, the primary LAB and right neighbor can drive on to the interconnect. For R4 interconnects that drive to the left, the primary LAB and its left neighbor can drive on to the interconnect. R4 interconnects can drive other R4 interconnects to extend the range of LABs they can drive. R4 interconnects can also drive C4 and C16 interconnects for connections from one row to another. Additionally, R4 interconnects can drive R24 interconnects. Figure 2-16. R4 Interconnect Connections Notes (1), (2), (3)
C4 and C16 Column Interconnects (1) R4 Interconnect Driving Right
Adjacent LAB can Drive onto Another LAB's R4 Interconnect R4 Interconnect Driving Left
LAB Neighbor
Primary LAB (2)
LAB Neighbor
Notes to Figure 2-16:
(1) (2) (3) C4 and C16 interconnects can drive R4 interconnects. This pattern is repeated for every LAB in the LAB row. The LABs in Figure 2-16 show the 16 possible logical outputs per LAB.
Altera Corporation March 2005
2-23 Stratix II Device Handbook, Volume 1
MultiTrack Interconnect
R24 row interconnects span 24 LABs and provide the fastest resource for long row connections between LABs, TriMatrix memory, DSP blocks, and Row IOEs. The R24 row interconnects can cross M-RAM blocks. R24 row interconnects drive to other row or column interconnects at every fourth LAB and do not drive directly to LAB local interconnects. R24 row interconnects drive LAB local interconnects via R4 and C4 interconnects. R24 interconnects can drive R24, R4, C16, and C4 interconnects. The column interconnect operates similarly to the row interconnect and vertically routes signals to and from LABs, TriMatrix memory, DSP blocks, and IOEs. Each column of LABs is served by a dedicated column interconnect. These column resources include:

Shared arithmetic chain interconnects in an LAB Carry chain interconnects in an LAB and from LAB to LAB Register chain interconnects in an LAB C4 interconnects traversing a distance of four blocks in up and down direction C16 column interconnects for high-speed vertical routing through the device
Stratix II devices include an enhanced interconnect structure in LABs for routing shared arithmetic chains and carry chains for efficient arithmetic functions. The register chain connection allows the register output of one ALM to connect directly to the register input of the next ALM in the LAB for fast shift registers. These ALM to ALM connections bypass the local interconnect. The Quartus II Compiler automatically takes advantage of these resources to improve utilization and performance. Figure 2-17 shows the shared arithmetic chain, carry chain and register chain interconnects.
2-24 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-17. Shared Arithmetic Chain, Carry Chain & Register Chain Interconnects
Local Interconnect Routing Among ALMs in the LAB Carry Chain & Shared Arithmetic Chain Routing to Adjacent ALM
ALM 1
ALM 2
Register Chain Routing to Adjacent ALM's Register Inpu
Local Interconnect
ALM 3 ALM 4 ALM 5 ALM 6 ALM 7
ALM 8
The C4 interconnects span four LABs, M512, or M4K blocks up or down from a source LAB. Every LAB has its own set of C4 interconnects to drive either up or down. Figure 2-18 shows the C4 interconnect connections from an LAB in a column. The C4 interconnects can drive and be driven by all types of architecture blocks, including DSP blocks, TriMatrix memory blocks, and column and row IOEs. For LAB interconnection, a primary LAB or its LAB neighbor can drive a given C4 interconnect. C4 interconnects can drive each other to extend their range as well as drive row interconnects for column-to-column connections.
Altera Corporation March 2005
2-25 Stratix II Device Handbook, Volume 1
MultiTrack Interconnect
Figure 2-18. C4 Interconnect Connections Note (1)
C4 Interconnect Drives Local and R4 Interconnects up to Four Rows
C4 Interconnect Driving Up
LAB
Row Interconnect
Adjacent LAB can drive onto neighboring LAB's C4 interconnect
Local Interconnect
C4 Interconnect Driving Down
Note to Figure 2-18:
(1) Each C4 interconnect can drive either up or down four rows.
2-26 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
C16 column interconnects span a length of 16 LABs and provide the fastest resource for long column connections between LABs, TriMatrix memory blocks, DSP blocks, and IOEs. C16 interconnects can cross M-RAM blocks and also drive to row and column interconnects at every fourth LAB. C16 interconnects drive LAB local interconnects via C4 and R4 interconnects and do not drive LAB local interconnects directly. All embedded blocks communicate with the logic array similar to LABto-LAB interfaces. Each block (that is, TriMatrix memory and DSP blocks) connects to row and column interconnects and has local interconnect regions driven by row and column interconnects. These blocks also have direct link interconnects for fast connections to and from a neighboring LAB. All blocks are fed by the row LAB clocks, labclk[5..0]. Table 2-2 shows the Stratix II device's routing scheme.
Table 2-2. Stratix II Device Routing Scheme (Part 1 of 2) Destination Shared Arithmetic Chain Direct Link Interconnect Local Interconnect M512 RAM Block R24 Interconnect C16 Interconnect
M4K RAM Block
R4 Interconnect
C4 Interconnect
Register Chain
M-RAM Block
Carry Chain
Column IOE
DSP Blocks
Shared arithmetic chain Carry chain Register chain Local interconnect Direct link interconnect R4 interconnect R24 interconnect C4 interconnect C16 interconnect ALM M512 RAM block M4K RAM block M-RAM block DSP blocks
v v v vvvvvvv v v v vvvv vvvv v v v v v v vvvv vvvvvv vvv vvv vv
vvvv
Altera Corporation March 2005
2-27 Stratix II Device Handbook, Volume 1
ALM
Source
Row IOE
TriMatrix Memory
Table 2-2. Stratix II Device Routing Scheme (Part 2 of 2) Destination Shared Arithmetic Chain Direct Link Interconnect Local Interconnect M512 RAM Block R24 Interconnect C16 Interconnect
M4K RAM Block
R4 Interconnect
C4 Interconnect
Register Chain
M-RAM Block
Carry Chain
Column IOE
DSP Blocks
Column IOE Row IOE
v
vv
vvvv
TriMatrix Memory
TriMatrix memory consists of three types of RAM blocks: M512, M4K, and M-RAM. Although these memory blocks are different, they can all implement various types of memory with or without parity, including true dual-port, simple dual-port, and single-port RAM, ROM, and FIFO buffers. Table 2-3 shows the size and features of the different RAM blocks.
Memory Block Size
TriMatrix memory provides three different memory sizes for efficient application support. The Quartus II software automatically partitions the user-defined memory into the embedded memory blocks using the most efficient size combinations. The designer can also manually assign the memory to a specific block size or a mixture of block sizes.
M512 RAM Block
The M512 RAM block is a simple dual-port memory block and is useful for implementing small FIFO buffers, DSP, and clock domain transfer applications. Each block contains 576 RAM bits (including parity bits). M512 RAM blocks can be configured in the following modes:

Simple dual-port RAM Single-port RAM FIFO ROM Shift register
2-28 Stratix II Device Handbook, Volume 1
ALM
Source
Altera Corporation March 2005
Row IOE
Stratix II Architecture
Table 2-3. TriMatrix Memory Features Memory Feature
Maximum performance True dual-port memory Simple dual-port memory Single-port memory Shift register ROM FIFO buffer Pack mode Byte enable Address clock enable Parity bits Mixed clock mode Memory initialization (.mif) Simple dual-port memory mixed width support True dual-port memory mixed width support Power-up conditions Register clears Outputs cleared Output registers
M512 RAM Block (32 x 18 Bits)
500 MHz
M4K RAM Block (128 x 36 Bits)
550 MHz
M-RAM Block (4K x 144 Bits)
400 MHz
v v v v v v v v v v v v v v v v v v v v v v v v
Outputs cleared Output registers
v v v
(1)
v v v v v v v v
Outputs unknown Output registers
Mixed-port read-during-write Unknown output/old data Unknown output/old data Unknown output Configurations 512 x 1 256 x 2 128 x 4 64 x 8 64 x 9 32 x 16 32 x 18 4K x 1 2K x 2 1K x 4 512 x 8 512 x 9 256 x 16 256 x 18 128 x 32 128 x 36 64K x 8 64K x 9 32K x 16 32K x 18 16K x 32 16K x 36 8K x 64 8K x 72 4K x 128 4K x 144
Notes to Table 2-3:
(1) The M-RAM block does not support memory initializations. However, the M-RAM block can emulate a ROM function using a dual-port RAM bock. The Stratix II device must write to the dual-port memory once and then disable the write-enable ports afterwards.
Altera Corporation March 2005
2-29 Stratix II Device Handbook, Volume 1
TriMatrix Memory
1
Violating the setup or hold time on the memory block address registers could corrupt memory contents. This applies to both read and write operations.
When configured as RAM or ROM, the designer can use an initialization file to pre-load the memory contents. M512 RAM blocks can have different clocks on its inputs and outputs. The wren, datain, and write address registers are all clocked together from one of the two clocks feeding the block. The read address, rden, and output registers can be clocked by either of the two clocks driving the block. This allows the RAM block to operate in read/write or input/output clock modes. Only the output register can be bypassed. The six labclk signals or local interconnect can drive the inclock, outclock, wren, rden, and outclr signals. Because of the advanced interconnect between the LAB and M512 RAM blocks, ALMs can also control the wren and rden signals and the RAM clock, clock enable, and asynchronous clear signals. Figure 2-19 shows the M512 RAM block control signal generation logic. The RAM blocks in Stratix II devices have local interconnects to allow ALMs and interconnects to drive into RAM blocks. The M512 RAM block local interconnect is driven by the R4, C4, and direct link interconnects from adjacent LABs. The M512 RAM blocks can communicate with LABs on either the left or right side through these row interconnects or with LAB columns on the left or right side with the column interconnects. The M512 RAM block has up to 16 direct link input connections from the left adjacent LABs and another 16 from the right adjacent LAB. M512 RAM outputs can also connect to left and right LABs through direct link interconnect. The M512 RAM block has equal opportunity for access and performance to and from LABs on either its left or right side. Figure 2-20 shows the M512 RAM block to logic array interface.
2-30 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-19. M512 RAM Block Control Signals
Dedicated Row LAB Clocks Local Interconnect 6
Local Interconnect
Local Interconnect Local Interconnect
Local Interconnect Local Interconnect Local Interconnect Local Interconnect inclock
inclocken
outclocken
wren outclr
outclock
rden
Altera Corporation March 2005
2-31 Stratix II Device Handbook, Volume 1
TriMatrix Memory
Figure 2-20. M512 RAM Block LAB Row Interface
C4 Interconnect R4 Interconnect
Direct link interconnect to adjacent LAB
16
Direct link interconnect to adjacent LAB dataout
Direct link interconnect from adjacent LAB
M512 RAM Block clocks control signals
Direct link interconnect from adjacent LAB
datain
address
2 6
M512 RAM Block Local Interconnect Region
LAB Row Clocks
M4K RAM Blocks
The M4K RAM block includes support for true dual-port RAM. The M4K RAM block is used to implement buffers for a wide variety of applications such as storing processor code, implementing lookup schemes, and implementing larger memory applications. Each block contains 4,608 RAM bits (including parity bits). M4K RAM blocks can be configured in the following modes:

True dual-port RAM Simple dual-port RAM Single-port RAM FIFO ROM Shift register
When configured as RAM or ROM, the designer can use an initialization file to pre-load the memory contents.
2-32 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
The M4K RAM blocks allow for different clocks on their inputs and outputs. Either of the two clocks feeding the block can clock M4K RAM block registers (renwe, address, byte enable, datain, and output registers). Only the output register can be bypassed. The six labclk signals or local interconnects can drive the control signals for the A and B ports of the M4K RAM block. ALMs can also control the clock_a, clock_b, renwe_a, renwe_b, clr_a, clr_b, clocken_a, and clocken_b signals, as shown in Figure 2-21. The R4, C4, and direct link interconnects from adjacent LABs drive the M4K RAM block local interconnect. The M4K RAM blocks can communicate with LABs on either the left or right side through these row resources or with LAB columns on either the right or left with the column resources. Up to 16 direct link input connections to the M4K RAM Block are possible from the left adjacent LABs and another 16 possible from the right adjacent LAB. M4K RAM block outputs can also connect to left and right LABs through direct link interconnect. Figure 2-22 shows the M4K RAM block to logic array interface. Figure 2-21. M4K RAM Block Control Signals
Dedicated Row LAB Clocks Local Interconnect Local Interconnect Local Interconnect Local Interconnect Local Interconnect Local Interconnect Local Interconnect Local Interconnect 6
clock_b
clocken_b renwe_a
renwe_b aclr_a
aclr_b
clock_a
clocken_a
Altera Corporation March 2005
2-33 Stratix II Device Handbook, Volume 1
TriMatrix Memory
Figure 2-22. M4K RAM Block LAB Row Interface
C4 Interconnect R4 Interconnect
Direct link interconnect to adjacent LAB
16 36 dataout
Direct link interconnect to adjacent LAB
Direct link interconnect from adjacent LAB
M4K RAM Block datain control signals clocks byte enable
Direct link interconnect from adjacent LAB
address
6
M4K RAM Block Local Interconnect Region
LAB Row Clocks
M-RAM Block
The largest TriMatrix memory block, the M-RAM block, is useful for applications where a large volume of data must be stored on-chip. Each block contains 589,824 RAM bits (including parity bits). The M-RAM block can be configured in the following modes:

True dual-port RAM Simple dual-port RAM Single-port RAM FIFO
The designer cannot use an initialization file to initialize the contents of a M-RAM block. All M-RAM block contents power up to an undefined value. Only synchronous operation is supported in the M-RAM block, so all inputs are registered. Output registers can be bypassed.
2-34 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Similar to all RAM blocks, M-RAM blocks can have different clocks on their inputs and outputs. Either of the two clocks feeding the block can clock M-RAM block registers (renwe, address, byte enable, datain, and output registers). The output register can be bypassed. The six labclk signals or local interconnect can drive the control signals for the A and B ports of the M-RAM block. ALMs can also control the clock_a, clock_b, renwe_a, renwe_b, clr_a, clr_b, clocken_a, and clocken_b signals as shown in Figure 2-23. Figure 2-23. M-RAM Block Control Signals
Dedicated Row LAB Clocks Local Interconnect Local Interconnect Local Interconnect Local Interconnect Local Interconnect Local Interconnect clock_a clocken_a renwe_a aclr_b renwe_b clocken_b clock_b 6
Local Interconnect Local Interconnect Local Interconnect Local Interconnect Local Interconnect Local Interconnect
aclr_a
The R4, R24, C4, and direct link interconnects from adjacent LABs on either the right or left side drive the M-RAM block local interconnect. Up to 16 direct link input connections to the M-RAM block are possible from the left adjacent LABs and another 16 possible from the right adjacent LAB. M-RAM block outputs can also connect to left and right LABs through direct link interconnect. Figure 2-24 shows an example floorplan for the EP2S130 device and the location of the M-RAM interfaces. Figures 2-25 and 2-26 show the interface between the M-RAM block and the logic array.
Altera Corporation March 2005
2-35 Stratix II Device Handbook, Volume 1
TriMatrix Memory
Figure 2-24. EP2S130 Device with M-RAM Interface Locations Note (1)
M-RAM blocks interface to LABs on right and left sides for easy access to horizontal I/O pins
M-RAM Block
M-RAM Block
M-RAM Block
M-RAM Block
M-RAM Block
M-RAM Block
M4K Blocks
M512 Blocks
DSP Blocks
LABs
DSP Blocks
Note to Figure 2-24:
(1) The device shown is an EP2S130 device. The number and position of M-RAM blocks varies in other devices.
2-36 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-25. M-RAM Block LAB Row Interface Note (1)
Row Unit Interface Allows LAB Rows to Drive Port A Datain, Dataout, Address and Control Signals to and from M-RAM Block Row Unit Interface Allows LAB Rows to Drive Port B Datain, Dataout, Address and Control Signals to and from M-RAM Block
L0 L1 M-RAM Block L2 Port A
R0 R1
Port B R2 R3 R4 R5
L3 L4 L5
LAB Interface Blocks LABs in Row M-RAM Boundary LABs in Row M-RAM Boundary
Note to Figure 2-25:
(1) Only R24 and C16 interconnects cross the M-RAM block boundaries.
Altera Corporation March 2005
2-37 Stratix II Device Handbook, Volume 1
TriMatrix Memory
Figure 2-26. M-RAM Row Unit Interface to Interconnect
C4 Interconnect R4 and R24 Interconnects
M-RAM Block
LAB
Up to 16 dataout_a[ ]
16
Direct Link Interconnects
Up to 28
datain_a[ ] addressa[ ] addr_ena_a renwe_a byteenaA[ ] clocken_a clock_a aclr_a
Row Interface Block
M-RAM Block to LAB Row Interface Block Interconnect Region
Table 2-4 shows the input and output data signal connections along with the address and control signal input connections to the row unit interfaces (L0 to L5 and R0 to R5). See the TriMatrix Embedded Memory Blocks in Stratix II Devices chapter in the Stratix II Device Handbook, Volume 2 for more information on TriMatrix memory.
2-38 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Table 2-4. M-RAM Row Interface Unit Signals Unit Interface Block
L0 L1 L2
Input Signals
datain_a[14..0] byteena_a[1..0] datain_a[29..15] byteena_a[3..2] datain_a[35..30] addressa[4..0] addr_ena_a clock_a clocken_a renwe_a aclr_a addressa[15..5] datain_a[41..36] datain_a[56..42] byteena_a[5..4] datain_a[71..57] byteena_a[7..6] datain_b[14..0] byteena_b[1..0] datain_b[29..15] byteena_b[3..2] datain_b[35..30] addressb[4..0] addr_ena_b clock_b clocken_b renwe_b aclr_b addressb[15..5] datain_b[41..36] datain_b[56..42] byteena_b[5..4] datain_b[71..57] byteena_b[7..6]
Output Signals
dataout_a[11..0] dataout_a[23..12] dataout_a[35..24]
L3 L4 L5 R0 R1 R2
dataout_a[47..36] dataout_a[59..48] dataout_a[71..60] dataout_b[11..0] dataout_b[23..12] dataout_b[35..24]
R3 R4 R5
dataout_b[47..36] dataout_b[59..48] dataout_b[71..60]
Altera Corporation March 2005
2-39 Stratix II Device Handbook, Volume 1
Digital Signal Processing Block
Digital Signal Processing Block
The most commonly used DSP functions are FIR filters, complex FIR filters, IIR filters, fast Fourier transform (FFT) functions, direct cosine transform (DCT) functions, and correlators. All of these use the multiplier as the fundamental building block. Additionally, some applications need specialized operations such as multiply-add and multiply-accumulate operations. Stratix II devices provide DSP blocks to meet the arithmetic requirements of these functions. Each Stratix II device has from two to four columns of DSP blocks to efficiently implement DSP functions faster than ALM-based implementations. Stratix II devices have up to 24 DSP blocks per column (see Table 2-5). Each DSP block can be configured to support up to:

Eight 9 x 9-bit multipliers Four 18 x 18-bit multipliers One 36 x 36-bit multiplier
As indicated, the Stratix II DSP block can support one 36 x 36-bit multiplier in a single DSP block. This is true for any combination of signed, unsigned, or mixed sign multiplications. 1 This list only shows functions that can fit into a single DSP block. Multiple DSP blocks can support larger multiplication functions.
Figure 2-27 shows one of the columns with surrounding LAB rows.
2-40 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-27. DSP Blocks Arranged in Columns
DSP Block Column
4 LAB Rows
DSP Block
Altera Corporation March 2005
2-41 Stratix II Device Handbook, Volume 1
Digital Signal Processing Block
Table 2-5 shows the number of DSP blocks in each Stratix II device.
Table 2-5. DSP Blocks in Stratix II Devices Note (1) Device
EP2S15 EP2S30 EP2S60 EP2S90 EP2S130 EP2S180 Note to Table 2-5:
(1) Each device has either the numbers of 9 x 9-, 18 x 18-, or 36 x 36-bit multipliers shown. The total number of multipliers for each device is not the sum of all the multipliers.
DSP Blocks
12 16 36 48 63 96
Total 9 x 9 Multipliers
96 128 288 384 504 768
Total 18 x 18 Multipliers
48 64 144 192 252 384
Total 36 x 36 Multipliers
12 16 36 48 63 96
DSP block multipliers can optionally feed an adder/subtractor or accumulator in the block depending on the configuration. This makes routing to ALMs easier, saves ALM routing resources, and increases performance, because all connections and blocks are in the DSP block. Additionally, the DSP block input registers can efficiently implement shift registers for FIR filter applications, and DSP blocks support Q1.15 format rounding and saturation. Figure 2-28 shows the top-level diagram of the DSP block configured for 18 x 18-bit multiplier mode.
2-42 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-28. DSP Block Diagram for 18 x 18-Bit Configuration
Optional Serial Shift Register Inputs from Previous DSP Block
Adder Output Block
PRN D
Multiplier Block
Q PRN
Q1.15 Round/ Saturate
Output Selection Multiplexer
ENA CLRN
D
Q
From the row interface block
D
PRN Q
ENA CLRN
Optional Stage Configurable as Accumulator or Dynamic Adder/Subtractor
ENA CLRN
Adder/ Subtractor/ Accumulator 1
Q1.15 Round/ Saturate
D
PRN Q PRN
Q1.15 Round/ Saturate
ENA CLRN
D
Q
D
PRN Q
ENA CLRN Summation Block
Adder
D Q ENA CLRN
ENA CLRN
PRN D Q ENA CLRN PRN
Q1.15 Round/ Saturate
D
Q
PRN D Q ENA CLRN
ENA CLRN
Summation Stage for Adding Four Multipliers Together
Adder/ Subtractor/ Accumulator 2
Q1.15 Round/ Saturate
D
PRN Q PRN
Q1.15 Round/ Saturate
ENA CLRN
D
Q
Optional Serial Shift Register Outputs to Next DSP Block in the Column
D
PRN Q
ENA CLRN
Optional Pipline Register Stage
ENA CLRN
Optional Input Register Stage with Parallel Input or Shift Register Configuration
to MultiTrack Interconnect
Altera Corporation March 2005
2-43 Stratix II Device Handbook, Volume 1
Digital Signal Processing Block
Modes of Operation
The adder, subtractor, and accumulate functions of a DSP block have four modes of operation:

Simple multiplier Multiply-accumulator Two-multipliers adder Four-multipliers adder
Table 2-6 shows the different number of multipliers possible in each DSP block mode according to size. These modes allow the DSP blocks to implement numerous applications for DSP including FFTs, complex FIR, FIR, and 2D FIR filters, equalizers, IIR, correlators, matrix multiplication and many other functions. The DSP blocks also support mixed modes and mixed multiplier sizes in the same block. For example, half of one DSP block can implement one 18 x 18-bit multiplier in multiplyaccumulator mode, while the other half of the DSP block implements four 9 x 9-bit multipliers in simple multiplier mode.
Table 2-6. Multiplier Size & Configurations per DSP Block DSP Block Mode
Multiplier Multiply-accumulator Two-multipliers adder
9x9
Eight multipliers with eight product outputs Four two-multiplier adder (two 9 x 9 complex multiply) Two four-multiplier adder
18 x 18
Four multipliers with four product outputs Two 52-bit multiplyaccumulate blocks Two two-multiplier adder (one 18 x 18 complex multiply) One four-multiplier adder
36 x 36
One multiplier with one product output -
Four-multipliers adder
-
DSP Block Interface
Stratix II device DSP block input registers can generate a shift register that can cascade down in the same DSP block column. Dedicated connections between DSP blocks provide fast connections between the shift register inputs to cascade the shift register chains. The designer can cascade registers within multiple DSP blocks for 9 x 9- or 18 x 18-bit FIR filters larger than four taps, with additional adder stages implemented in ALMs. If the DSP block is configured as 36 x 36 bits, the adder, subtractor, or accumulator stages are implemented in ALMs. Each DSP block can route the shift register chain out of the block to cascade multiple columns of DSP blocks.
2-44 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
The DSP block is divided into four block units that interface with four LAB rows on the left and right. Each block unit can be considered one complete 18 x 18-bit multiplier with 36 inputs and 36 outputs. A local interconnect region is associated with each DSP block. Like an LAB, this interconnect region can be fed with 16 direct link interconnects from the LAB to the left or right of the DSP block in the same row. R4 and C4 routing resources can access the DSP block's local interconnect region. The outputs also work similarly to LAB outputs as well. Eighteen outputs from the DSP block can drive to the left LAB through direct link interconnects and eighteen can drive to the right LAB though direct link interconnects. All 36 outputs can drive to R4 and C4 routing interconnects. Outputs can drive right- or left-column routing. Figures 2-29 and 2-30 show the DSP block interfaces to LAB rows. Figure 2-29. DSP Block Interconnect Interface
DSP Block
R4, C4 & Direct Link Interconnects
OA[17..0] OB[17..0] A1[17..0] B1[17..0]
R4, C4 & Direct Link Interconnects
OC[17..0] OD[17..0] A2[17..0] B2[17..0]
OE[17..0] OF[17..0]
A3[17..0] B3[17..0]
OG[17..0] OH[17..0]
A4[17..0] B4[17..0]
Altera Corporation March 2005
2-45 Stratix II Device Handbook, Volume 1
Digital Signal Processing Block
Figure 2-30. DSP Block Interface to Interconnect
C4 Interconnect Direct Link Interconnect from Adjacent LAB R4 Interconnect Direct Link Outputs to Adjacent LABs Direct Link Interconnect from Adjacent LAB
36 DSP Block Row Structure
LAB 18
36
LAB
16
16
12 Control 36 A[17..0] B[17..0] OA[17..0] OB[17..0] 36
Row Interface Block
DSP Block to LAB Row Interface Block Interconnect Region
36 Inputs per Row
36 Outputs per Row
A bus of 44 control signals feeds the entire DSP block. These signals include clocks, asynchronous clears, clock enables, signed/unsigned control signals, addition and subtraction control signals, rounding and saturation control signals, and accumulator synchronous loads. The clock
2-46 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
signals are routed from LAB row clocks and are generated from specific LAB rows at the DSP block interface. The LAB row source for control signals, data inputs, and outputs is shown in Table 2-7.
Table 2-7. DSP Block Signal Sources & Destinations LAB Row at Interface
0
Control Signals Generated
clock0 aclr0 ena0 mult01_saturate addnsub1_round/ accum_round addnsub1 signa sourcea sourceb clock1 aclr1 ena1 accum_saturate mult01_round accum_sload sourcea sourceb mode0 clock2 aclr2 ena2 mult23_saturate addnsub3_round/ accum_round addnsub3 sign_b sourcea sourceb clock3 aclr3 ena3 accum_saturate mult23_round accum_sload sourcea sourceb mode1
Data Inputs
A1[17..0] B1[17..0]
Data Outputs
OA[17..0] OB[17..0]
1
A2[17..0] B2[17..0]
OC[17..0] OD[17..0]
2
A3[17..0] B3[17..0]
OE[17..0] OF[17..0]
3
A4[17..0] B4[17..0]
OG[17..0] OH[17..0]
See the DSP Blocks in Stratix II Devices chapter in the Stratix II Device Handbook, Volume 2 for more information on DSP blocks.
Altera Corporation March 2005
2-47 Stratix II Device Handbook, Volume 1
PLLs & Clock Networks
PLLs & Clock Networks
Stratix II devices provide a hierarchical clock structure and multiple PLLs with advanced features. The large number of clocking resources in combination with the clock synthesis precision provided by enhanced and fast PLLs provides a complete clock management solution.
Global & Hierarchical Clocking
Stratix II devices provide 16 dedicated global clock networks and 32 regional clock networks (eight per device quadrant). These clocks are organized into a hierarchical clock structure that allows for up to 24 clocks per device region with low skew and delay. This hierarchical clocking scheme provides up to 48 unique clock domains in Stratix II devices. There are 16 dedicated clock pins (CLK[15..0]) to drive either the global or regional clock networks. Four clock pins drive each side of the device, as shown in Figures 2-31 and 2-32. Internal logic and enhanced and fast PLL outputs can also drive the global and regional clock networks. Each global and regional clock has a clock control block, which controls the selection of the clock source and dynamically enables/disables the clock to reduce power consumption. Table 2-8 shows global and regional clock features.
Table 2-8. Global & Regional Clock Features Feature
Number per device Number available per quadrant Sources Dynamic clock source selection Dynamic enable/disable Note to Table 2-8:
(1) Dynamic source clock selection is supported for selecting between CLKp pins and PLL outputs only.
Global Clocks
16 16 CLK pins, PLL outputs, or internal logic
Regional Clocks
32 8 CLK pins, PLL outputs, or internal logic
v (1) v v
Global Clock Network
These clocks drive throughout the entire device, feeding all device quadrants. The global clock networks can be used as clock sources for all resources in the device-IOEs, ALMs, DSP blocks, and all memory blocks. These resources can also be used for control signals, such as clock enables and synchronous or asynchronous clears fed from the external pin. The
2-48 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
global clock networks can also be driven by internal logic for internally generated global clocks and asynchronous clears, clock enables, or other control signals with large fanout. Figure 2-31 shows the 16 dedicated CLK pins driving global clock networks. Figure 2-31. Global Clocking
CLK[15..12]
Global Clock [15..0]
CLK[3..0]
Global Clock [15..0]
CLK[11..8]
CLK[7..4]
Regional Clock Network
There are eight regional clock networks RCLK[7..0] in each quadrant of the Stratix II device that are driven by the dedicated CLK[15..0] input pins, by PLL outputs, or by internal logic. The regional clock networks provide the lowest clock delay and skew for logic contained in a single quadrant. The CLK clock pins symmetrically drive the RCLK networks in a particular quadrant, as shown in Figure 2-32.
Altera Corporation March 2005
2-49 Stratix II Device Handbook, Volume 1
PLLs & Clock Networks
Figure 2-32. Regional Clocks
RCLK[31..28] RCLK[27..24]
CLK[15..12]
RCLK[3..0] CLK[3..0]
RCLK[23..20] CLK[11..8]
RCLK[7..4]
RCLK[19..16]
CLK[7..4] Regional Clocks Only Drive a Device Quadrant from Specified CLK Pins, PLLs or Core Logic within that Quadrant RCLK[11..8] RCLK[15..12]
Dual-Regional Clock Network
A single source (CLK pin or PLL output) can generate a dual-regional clock by driving two regional clock network lines in adjacent quadrants (one from each quadrant). This allows logic that spans multiple quadrants to utilize the same low skew clock. The routing of this clock signal on an entire side has approximately the same speed but slightly higher clock skew when compared with a clock signal that drives a single quadrant. Internal logic-array routing can also drive a dual-regional clock. Clock pins and enhanced PLL outputs on the top and bottom can drive horizontal dual-regional clocks. Clock pins and fast PLL outputs on the left and right can drive vertical dual-regional clocks, as shown in Figure 2-33. Corner PLLs cannot drive dual-regional clocks.
2-50 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-33. Dual-Regional Clocks
Clock Pins or PLL Clock Outputs Can Drive Dual-Regional Network Clock Pins or PLL Clock Outputs Can Drive Dual-Regional Network
CLK[15..12]
CLK[15..12]
CLK[3..0]
CLK[11..8]
CLK[3..0]
CLK[11..8]
PLLs
PLLs
CLK[7..4]
CLK[7..4]
Combined Resources
Within each quadrant, there are 24 distinct dedicated clocking resources consisting of 16 global clock lines and eight regional clock lines. Multiplexers are used with these clocks to form busses to drive LAB row clocks, column IOE clocks, or row IOE clocks. Another multiplexer is used at the LAB level to select three of the six row clocks to feed the ALM registers in the LAB (see Figure 2-34). Figure 2-34. Hierarchical Clock Networks Per Quadrant
Clocks Available to a Quadrant or Half-Quadrant
Global Clock Network [15..0] Clock [23..0] Lab Row Clock [5..0] Regional Clock Network [7..0] Row I/O Cell IO_CLK[7..0] Column I/O Cell IO_CLK[7..0]
Altera Corporation March 2005
2-51 Stratix II Device Handbook, Volume 1
PLLs & Clock Networks
IOE clocks have row and column block regions that are clocked by eight I/O clock signals chosen from the 24 quadrant clock resources. Figures 2-35 and 2-36 show the quadrant relationship to the I/O clock regions. Figure 2-35. EP2S15 & EP2S30 Device I/O Clock Groups
IO_CLKA[7:0] IO_CLKB[7:0]
8
8
I/O Clock Regions
8
24 Clocks in the Quadrant
24 Clocks in the Quadrant
IO_CLKH[7:0]
8
IO_CLKC[7:0]
8
IO_CLKG[7:0]
24 Clocks in the Quadrant 24 Clocks in the Quadrant
IO_CLKD[7:0]
8
8
8
IO_CLKF[7:0]
IO_CLKE[7:0]
2-52 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-36. EP2S60, EP2S90, EP2S130 & EP2S180 Device I/O Clock Groups
IO_CLKA[7:0] IO_CLKB[7:0] IO_CLKC[7:0] IO_CLKD[7:0]
8
8
8
8
I/O Clock Regions
8
8
IO_CLKP[7:0]
24 Clocks in the Quadrant 8 24 Clocks in the Quadrant 8
IO_CLKE[7:0]
IO_CLKO[7:0]
IO_CLKF[7:0]
8
8
IO_CLKN[7:0]
24 Clocks in the Quadrant 8 24 Clocks in the Quadrant 8
IO_CLKG[7:0]
IO_CLKM[7:0]
IO_CLKH[7:0]
8
8
8
8
IO_CLKL[7:0]
IO_CLKK[7:0]
IO_CLKJ[7:0]
IO_CLKI[7:0]
Designers can use the Quartus II software to control whether a clock input pin drives either a global, regional, or dual-regional clock network. The Quartus II software automatically selects the clocking resources if not specified.
Clock Control Block
Each global clock, regional clock, and PLL external clock output has its own clock control block. The control block has two functions:

Clock source selection (dynamic selection for global clocks) Clock power-down (dynamic clock enable/disable)
Figures 2-37 through 2-39 show the clock control block for the global clock, regional clock, and PLL external clock output, respectively.
Altera Corporation March 2005
2-53 Stratix II Device Handbook, Volume 1
PLLs & Clock Networks
Figure 2-37. Global Clock Control Blocks
CLKp Pins PLL Counter Outputs CLKSELECT[1..0] (1) 2 2 CLKn Pin 2 Internal Logic
This multiplexer supports User-Controllable Dynamic Switching
Static Clock Select (2)
Enable/ Disable Internal Logic GCLK
Notes to Figure 2-37:
(1) (2) These clock select signals can be dynamically controlled through internal logic when the device is operating in user mode. These clock select signals can only be set through a configuration file (.sof or .pof) and cannot be dynamically controlled during user mode operation.
Figure 2-38. Regional Clock Control Blocks
CLKp Pin PLL Counter Outputs 2 CLKn Pin (2) Internal Logic Static Clock Select (1)
Enable/ Disable Internal Logic RCLK
Notes to Figure 2-38:
(1) (2) These clock select signals can only be set through a configuration file (.sof or .pof) and cannot be dynamically controlled during user mode operation. Only the CLKn pins on the top and bottom of the device feed to regional clock select blocks.
2-54 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-39. External PLL Output Clock Control Blocks
PLL Counter Outputs (c[5..0]) 6 Static Clock Select (1)
Enable/ Disable Internal Logic IOE (2) Internal Logic Static Clock Select (1)
PLL_OUT Pin
Notes to Figure 2-39:
(1) (2) These clock select signals can only be set through a configuration file (.sof or .pof) and cannot be dynamically controlled during user mode operation. The clock control block feeds to a multiplexer within the PLL_OUT pin's IOE. The PLL_OUT pin is a dual-purpose pin. Therefore, this multiplexer selects either an internal signal or the output of the clock control block.
For the global clock control block, the clock source selection can be controlled either statically or dynamically. The user has the option of statically selecting the clock source by using the Quartus II software to set specific configuration bits in the configuration file (.sof or .pof) or the user can control the selection dynamically by using internal logic to drive the multiplexor select inputs. When selecting statically, the clock source can be set to any of the inputs to the select multiplexor. When selecting the clock source dynamically, the user can either select between two PLL outputs (such as the C0 or C1 outputs from one PLL), between two PLLs (such as the C0/C1 clock output of one PLL or the C0/C1 c1ock output of the other PLL), between two clock pins (such as CLK0 or CLK1), or between a combination of clock pins or PLL outputs. For the regional and PLL_OUT clock control block, the clock source selection can only be controlled statically using configuration bits. Any of the inputs to the clock select multiplexor can be set as the clock source.
Altera Corporation March 2005
2-55 Stratix II Device Handbook, Volume 1
PLLs & Clock Networks
The Stratix II clock networks can be disabled (powered down) by both static and dynamic approaches. When a clock net is powered down, all the logic fed by the clock net is in an off-state thereby reducing the overall power consumption of the device. The global and regional clock networks can be powered down statically through a setting in the configuration (.sof or .pof) file. Clock networks that are not used are automatically powered down through configuration bit settings in the configuration file generated by the Quartus II software. The dynamic clock enable/disable feature allows the internal logic to control power up/down synchronously on GCLK and RCLK nets and PLL_OUT pins. This function is independent of the PLL and is applied directly on the clock network or PLL_OUT pin, as shown in Figures 2-37 through 2-39.
Enhanced & Fast PLLs
Stratix II devices provide robust clock management and synthesis using up to four enhanced PLLs and eight fast PLLs. These PLLs increase performance and provide advanced clock interfacing and clockfrequency synthesis. With features such as clock switchover, spread spectrum clocking, reconfigurable bandwidth, phase control, and reconfigurable phase shifting, the Stratix II device's enhanced PLLs provide designers with complete control of their clocks and system timing. The fast PLLs provide general purpose clocking with multiplication and phase shifting as well as high-speed outputs for highspeed differential I/O support. Enhanced and fast PLLs work together with the Stratix II high-speed I/O and advanced clock architecture to provide significant improvements in system performance and bandwidth.
2-56 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
The Quartus II software enables the PLLs and their features without requiring any external devices. Table 2-9 shows the PLLs available for each Stratix II device and their type.
Table 2-9. Stratix II Device PLL Availability Fast PLLs Device 1
EP2S15 EP2S30 EP2S60 (1) EP2S90 (2) EP2S130 (3) EP2S180
Enhanced PLLs 8 9 10 5 v v 6 v v v v v v v v v v v v v v 11 12
2 v v v v v v
3 v v v v v v
4 v v v v v v
7
v v v v v v
v v v v
v v v v
v v v v
v v v v
v v v v
Notes to Table 2-9:
(1) (2) (3) EP2S60 devices in the 1020-pin package contain 12 PLLs. EP2S60 devices in the 484-pin and 672-pin packages contain fast PLLs 1-4 and enhanced PLLs 5 and 6. EP2S90 devices in the 1020-pin and 1508-pin packages contain 12 PLLs. EP2S90 devices in the 484-pin and 780-pin packages contain fast PLLS 1-4 and enhanced PLLs 5 and 6. EP2S130 devices in the 1020-pin and 1508-pin packages contain 12PLLs. The EP2S130 device in the 780-pin package contains fast PLLs 1-4 and enhanced PLLs 5 and 6.
Altera Corporation March 2005
2-57 Stratix II Device Handbook, Volume 1
PLLs & Clock Networks
Table 2-10 shows the enhanced PLL and fast PLL features in Stratix II devices.
Table 2-10. Stratix II PLL Features Feature
Clock multiplication and division Phase shift Clock switchover PLL reconfiguration Reconfigurable bandwidth Spread spectrum clocking Programmable duty cycle Number of internal clock outputs Number of external clock outputs Number of feedback clock inputs Notes to Table 2-10:
(1) (2) (3) (4) (5) (6) (7) (8) For enhanced PLLs, m, n, range from 1 to 512 and post-scale counters range from 1 to 512 with 50% duty cycle. For fast PLLs, m, and post-scale counters range from 1 to 32. The n counter ranges from 1 to 4. The smallest phase shift is determined by the voltage controlled oscillator (VCO) period divided by 8. For degree increments, Stratix II devices can shift all output frequencies in increments of at least 45. Smaller degree increments are possible depending on the frequency and divide parameters. Stratix II fast PLLs only support manual clock switchover. Fast PLLs can drive to any I/O pin as an external clock. For high-speed differential I/O pins, the device uses a data channel to generate txclkout. If the feedback input is used, you will lose one (or two, if FBIN is differential) external clock output pin. Every Stratix II device has at least two enhanced PLLs with one single-ended or differential external feedback input per PLL.
Enhanced PLL
m/(n x post-scale counter) (1) Down to 125-ps increments (3), (4)
Fast PLL
m/(n x post-scale counter) (2) Down to 125-ps increments (3), (4)
v v v v v
6 Three differential/six single-ended One single-ended or differential (7), (8)
v (5) v v v
4 (6)
Figure 2-40 shows a top-level diagram of the Stratix II device and PLL floorplan.
2-58 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-40. PLL Locations
CLK[15..12] 11 5
FPLL7CLK
7
10
FPLL10CLK
CLK[3..0]
1 2
4 3
CLK[8..11]
PLLs
FPLL8CLK
8
9
FPLL9CLK
12
6
CLK[7..4]
Figures 2-41 and 2-42 shows the global and regional clocking from the fast PLL outputs and the side clock pins. The connections to the global and regional clocks from the fast PLL outputs, internal drivers, and the CLK pins on the left and right sides of the device are shown in table format in Tables 2-11 and 2-12, respectively.
Altera Corporation March 2005
2-59 Stratix II Device Handbook, Volume 1
PLLs & Clock Networks
Figure 2-41. Global & Regional Clock Connections from Center Clock Pins & Fast PLL Outputs Note (1)
CLK11 CLK10 CLK9 C2 C3 C0 C1 C2 Fast PLL 3 C3 CLK8
C0
C1
Fast PLL 4
RCK23 RCK21 RCK19 RCK17 GCK11 GCK9
Logic Array Signal Input To Clock Network
GCK2 GCK0 RCK6 RCK4 RCK2 C0 C1 C2 C3 C0 C1 C2 Fast PLL 1 CLK0 CLK1 CLK2 Fast PLL 2
Notes to Figure 2-41:
(1) EP2S15 and EP2S30 devices only have four fast PLLs (1, 2, 3, and 4), but the connectivity from these four PLLs to the global and regional clock networks remains the same as shown. The global or regional clocks in a fast PLL's quadrant can drive the fast PLL input. A pin or other PLL must drive the global or regional source. The source cannot be driven by internally generated logic before driving the fast PLL.
(2)
2-60 Stratix II Device Handbook, Volume 1
CLK3
C3
RCK0
Altera Corporation March 2005
RCK1
RCK3
RCK5
RCK7
GCK1
GCK3
GCK8
GCK10
RCK16
RCK18
RCK20
RCK22
Stratix II Architecture
Figure 2-42. Global & Regional Clock Connections from Corner Clock Pins & Fast PLL Outputs Note (1)
FPLL10CLK FPLL9CLK
Fast PLL 10
C0
C1
C2
C3
C0
C1
C2
Fast PLL 9 C3
RCK23
RCK22
RCK19 RCK17 GCK11 GCK9 GCK2 GCK0 RCK6 C0 C1 C2 C3 C0 C1 C2 Fast PLL 7
FPLL7CLK FPLL8CLK
RCK20
RCK21
RCK3
RCK2
RCK1
RCK0
Note to Figure 2-42:
(1) The corner fast PLLs can also be driven through the global or regional clock networks. The global or regional clock input to the fast PLL can be driven from another PLL, a pin-driven global or regional clock, or internally generated global signals.
Altera Corporation March 2005
2-61 Stratix II Device Handbook, Volume 1
Fast PLL 8
C3
RCK4
RCK5
RCK7
GCK1
GCK3
GCK8
GCK10
RCK16
RCK18
PLLs & Clock Networks
Table 2-11. Global & Regional Clock Connections from Left Side Clock Pins & Fast PLL Outputs (Part 1 of 2) RCLK0 RCLK1 RCLK2 RCLK3 RCLK4 RCLK5 RCLK6 v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v CLK0 CLK1 CLK2 CLK3 Left Side Global & Regional Clock Network Connectivity
Clock pins CLK0p CLK1p CLK2p CLK3p Drivers from internal logic GCLKDRV0 GCLKDRV1 GCLKDRV2 GCLKDRV3 RCLKDRV0 RCLKDRV1 RCLKDRV2 RCLKDRV3 RCLKDRV4 RCLKDRV5 RCLKDRV6 RCLKDRV7 PLL 1 outputs c0 c1 c2 c3 PLL 2 outputs c0 c1 c2 c3
v v
v v v v v v
v v v
v v
v v
v v v v v v v v v v v
2-62 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
RCLK7
Stratix II Architecture
Table 2-11. Global & Regional Clock Connections from Left Side Clock Pins & Fast PLL Outputs (Part 2 of 2) RCLK0 RCLK1 RCLK2 RCLK3 RCLK4 RCLK5 RCLK6 v v v v v v v RCLK22 v v v v v v CLK0 CLK1 CLK2 CLK3 Left Side Global & Regional Clock Network Connectivity
PLL 7 outputs c0 c1 c2 c3 PLL 8 outputs c0 c1 c2 c3
v v v v v v v v v v v v
v v v
v v v v v
v v
v v
v
Table 2-12. Global & Regional Clock Connections from Right Side Clock Pins & Fast PLL Outputs (Part 1 of 2) RCLK16 RCLK17 RCLK18 RCLK19 RCLK20 RCLK21 CLK10 CLK11 CLK8 CLK9 Right Side Global & Regional Clock Network Connectivity
Clock pins CLK8p CLK9p CLK10p CLK11p Drivers from internal logic GCLKDRV0 GCLKDRV1 GCLKDRV2 GCLKDRV3 RCLKDRV0 RCLKDRV1 RCLKDRV2 RCLKDRV3
v v
v v v v v v
v v v
v v
v v
v v v v v v v v v v v
Altera Corporation March 2005
2-63 Stratix II Device Handbook, Volume 1
RCLK23
RCLK7
PLLs & Clock Networks
Table 2-12. Global & Regional Clock Connections from Right Side Clock Pins & Fast PLL Outputs (Part 2 of 2) RCLK16 RCLK17 RCLK18 RCLK19 RCLK20 RCLK21 RCLK22 v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v CLK10 CLK11 CLK8 CLK9 Right Side Global & Regional Clock Network Connectivity
RCLKDRV4 RCLKDRV5 RCLKDRV6 RCLKDRV7 PLL 3 outputs c0 c1 c2 c3 PLL 4 outputs c0 c1 c2 c3 PLL 9 outputs c0 c1 c2 c3 PLL 10 outputs c0 c1 c2 c3
v v v
v v
Figure 2-43 shows the global and regional clocking from enhanced PLL outputs and top and bottom CLK pins. The connections to the global and regional clocks from the top clock pins and enhanced PLL outputs is shown in Table 2-13. The connections to the clocks from the bottom clock pins is shown in Table 2-14.
2-64 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
RCLK23
Stratix II Architecture
Figure 2-43. Global & Regional Clock Connections from Top & Bottom Clock Pins & Enhanced PLL Outputs Note (1)
CLK13
(2)
CLK15
(2) PLL5_FB
CLK12
CLK14
PLL11_FB
PLL 11
PLL 5
c0 c1 c2 c3 c4 c5
PLL11_OUT[2..0]p PLL11_OUT[2..0]n
c0 c1 c2 c3 c4 c5
PLL5_OUT[2..0]p PLL5_OUT[2..0]n RCLK31 RCLK30 RCLK29 RCLK28
Regional Clocks
RCLK27 RCLK26 RCLK25 RCLK24 G15 G14 G13 G12
Global Clocks
G4 G5 G6 G7
Regional Clocks
RCLK8 RCLK9 RCLK10 RCLK11 RCLK12 RCLK13 RCLK14 RCLK15 PLL6_OUT[2..0]p PLL6_OUT[2..0]n
PLL12_OUT[2..0]p PLL12_OUT[2..0]n
c0 c1 c2 c3 c4 c5 PLL 12
c0 c1 c2 c3 c4 c5
PLL 6
PLL12_FB (2) CLK4 CLK5
CLK6 CLK7
PLL6_FB (2)
Notes to Figure 2-43:
(1) (2) EP2S15 and EP2S30 devices only have two enhanced PLLs (5 and 6), but the connectivity from these two PLLs to the global and regional clock networks remains the same as shown. If the design uses the feedback input, you will lose one (or two, if FBIN is differential) external clock output pin.
Altera Corporation March 2005
2-65 Stratix II Device Handbook, Volume 1
PLLs & Clock Networks
Table 2-13. Global & Regional Clock Connections from Top Clock Pins & Enhanced PLL Outputs (Part 1 of 2) RCLK24 RCLK25 RCLK26 RCLK27 RCLK28 RCLK29 RCLK30 v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v Top Side Global & Regional Clock Network Connectivity
Clock pins CLK12p CLK13p CLK14p CLK15p CLK12n CLK13n CLK14n CLK15n Drivers from internal logic GCLKDRV0 GCLKDRV1 GCLKDRV2 GCLKDRV3 RCLKDRV0 RCLKDRV1 RCLKDRV2 RCLKDRV3 RCLKDRV4 RCLKDRV5 RCLKDRV6 RCLKDRV7 Enhanced PLL5 outputs c0 c1 c2 c3 c4 c5
v v v v
v v
v v v v v v
v v v
v v
v
2-66 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
RCLK31
DLLCLK
CLK12
CLK13
CLK14
CLK15
Stratix II Architecture
Table 2-13. Global & Regional Clock Connections from Top Clock Pins & Enhanced PLL Outputs (Part 2 of 2) RCLK24 RCLK25 RCLK26 RCLK27 RCLK28 RCLK29 RCLK30 v v v v v v v v v v v RCLK14 v v v v v v v v v v v v v v v v v v v v Top Side Global & Regional Clock Network Connectivity
Enhanced PLL 11 outputs c0 c1 c2 c3 c4 c5
v v
v v v v v v
v v v
v v
Table 2-14. Global & Regional Clock Connections from Bottom Clock Pins & Enhanced PLL Outputs (Part 1 of 2) Bottom Side Global & Regional Clock Network Connectivity
Clock pins CLK4p CLK5p CLK6p CLK7p CLK4n CLK5n CLK6n CLK7n Drivers from internal logic GCLKDRV0 GCLKDRV1 GCLKDRV2 GCLKDRV3 RCLKDRV0
DLLCLK
RCLK10
RCLK11
RCLK12
RCLK13
v v v v
v v
v v v v v v
v v v
v v
v
Altera Corporation March 2005
2-67 Stratix II Device Handbook, Volume 1
RCLK15
RCLK8
RCLK9
CLK4
CLK5
CLK6
CLK7
RCLK31
DLLCLK
CLK12
CLK13
CLK14
CLK15
PLLs & Clock Networks
Table 2-14. Global & Regional Clock Connections from Bottom Clock Pins & Enhanced PLL Outputs (Part 2 of 2) Bottom Side Global & Regional Clock Network Connectivity
RCLKDRV1 RCLKDRV2 RCLKDRV3 RCLKDRV4 RCLKDRV5 RCLKDRV6 RCLKDRV7 Enhanced PLL 6 outputs c0 c1 c2 c3 c4 c5 Enhanced PLL 12 outputs c0 c1 c2 c3 c4 c5
DLLCLK
RCLK10
RCLK11
RCLK12
RCLK13
RCLK14 v v v v v v
v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v v
v v v v
v v v v
v v v v
Enhanced PLLs
Stratix II devices contain up to four enhanced PLLs with advanced clock management features. Figure 2-44 shows a diagram of the enhanced PLL.
2-68 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
RCLK15
RCLK8
RCLK9
CLK4
CLK5
CLK6
CLK7
Stratix II Architecture
Figure 2-44. Stratix II Enhanced PLL Note (1)
VCO Phase Selection Selectable at Each PLL Output Port From Adjacent PLL Post-Scale Counters
Clock Switchover Circuitry INCLK[3..0] 4 /n
Phase Frequency Detector
Spread Spectrum
/c0
/c1 4 PFD Charge Pump Loop Filter 8 VCO /c2 6 /c3 6 /m (2) /c5 FBIN Lock Detect & Filter to I/O or general routing /c4 I/O Buffers (3) 8 Regional Clocks Global Clocks
Global or Regional Clock
Shaded Portions of the PLL are Reconfigurable
VCO Phase Selection Affecting All Outputs
Notes to Figure 2-44:
(1) (2) (3) Each clock source can come from any of the four clock pins that are physically located on the same side of the device as the PLL. If the feedback input is used, you will lose one (or two, if FBIN is differential) external clock output pin. Each enhanced PLL has three differential external clock outputs or six single-ended external clock outputs.
Fast PLLs
Stratix II devices contain up to eight fast PLLs with high-speed serial interfacing ability. Figure 2-45 shows a diagram of the fast PLL.
Altera Corporation March 2005
2-69 Stratix II Device Handbook, Volume 1
I/O Structure
Figure 2-45. Stratix II Device Fast PLL
Notes (1), (2), (3)
VCO Phase Selection Selectable at each PLL Output Port Post-Scale Counters
Global or regional clock (1)
Clock Switchover Circuitry (4)
Phase Frequency Detector
diffioclk0 (2) /c0 8 /c1 4 /c2 Global clocks 4 /c3 /m 8 to DPA block 8 Regional clocks load_en0 (3)
Clock Input
4
/n
PFD
Charge Pump
Loop Filter
VCO
/k
load_en1 (3) diffioclk1 (2)
Global or regional clock (1)
Shaded Portions of the PLL are Reconfigurable
Notes to Figure 2-45:
(1) (2) (3) (4) The global or regional clock input can be driven by an output from another PLL or a pin-driven global or regional clock. It cannot be driven by internally-generated global signals. In high-speed differential I/O support mode, this high-speed PLL clock feeds the SERDES circuitry. Stratix II devices only support one rate of data transfer per fast PLL in high-speed differential I/O support mode. This signal is a differential I/O SERDES control signal. Stratix II fast PLLs only support manual clock switchover.
See the PLLs in Stratix II Devices chapter in the Stratix II Device Handbook, Volume 2 for more information on enhanced and fast PLLs. See "HighSpeed Differential I/O with DPA Support" for more information on highspeed differential I/O support.
I/O Structure
The Stratix II IOEs provide many features, including:

Dedicated differential and single-ended I/O buffers 3.3-V, 64-bit, 66-MHz PCI compliance 3.3-V, 64-bit, 133-MHz PCI-X 1.0 compliance Joint Test Action Group (JTAG) boundary-scan test (BST) support On-chip driver series termination On-chip termination for differential standards Programmable pull-up during configuration Output drive strength control Tri-state buffers Bus-hold circuitry Programmable pull-up resistors Programmable input and output delays Open-drain outputs DQ and DQS I/O pins Double data rate (DDR) registers
2-70 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
The IOE in Stratix II devices contains a bidirectional I/O buffer, six registers, and a latch for a complete embedded bidirectional single data rate or DDR transfer. Figure 2-46 shows the Stratix II IOE structure. The IOE contains two input registers (plus a latch), two output registers, and two output enable registers. The design can use both input registers and the latch to capture DDR input and both output registers to drive DDR outputs. Additionally, the design can use the output enable (OE) register for fast clock-to-output enable timing. The negative edge-clocked OE register is used for DDR SDRAM interfacing. The Quartus II software automatically duplicates a single OE register that controls multiple output or bidirectional pins.
Altera Corporation March 2005
2-71 Stratix II Device Handbook, Volume 1
I/O Structure
Figure 2-46. Stratix II IOE Structure
Logic Array OE Register OE
D Q
OE Register
D Q
Output Register Output A
D Q
CLK
Output Register Output B
D Q
Input Register
D Q
Input A Input B Input Register
D Q
Input Latch
D ENA Q
The IOEs are located in I/O blocks around the periphery of the Stratix II device. There are up to four IOEs per row I/O block and four IOEs per column I/O block. The row I/O blocks drive row, column, or direct link interconnects. The column I/O blocks drive column interconnects. Figure 2-47 shows how a row I/O block connects to the logic array. Figure 2-48 shows how a column I/O block connects to the logic array.
2-72 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-47. Row I/O Block Connection to the Interconnect Note (1)
R4 & R24 Interconnects
C4 Interconnect I/O Block Local Interconnect
32 Data & Control Signals from Logic Array (1)
LAB 32 Horizontal I/O Block
io_dataina[3..0] io_datainb[3..0]
Direct Link Interconnect to Adjacent LAB LAB Local Interconnect
Direct Link Interconnect to Adjacent LAB
io_clk[7:0]
Horizontal I/O Block Contains up to Four IOEs
Note to Figure 2-47:
(1) The 32 data and control signals consist of eight data out lines: four lines each for DDR applications io_dataouta[3..0] and io_dataoutb[3..0], four output enables io_oe[3..0], four input clock enables io_ce_in[3..0], four output clock enables io_ce_out[3..0], four clocks io_clk[3..0], four asynchronous clear and preset signals io_aclr/apreset[3..0], and four synchronous clear and preset signals io_sclr/spreset[3..0].
Altera Corporation March 2005
2-73 Stratix II Device Handbook, Volume 1
I/O Structure
Figure 2-48. Column I/O Block Connection to the Interconnect Note (1)
32 Data & Control Signals from Logic Array (1)
Vertical I/O Block
Vertical I/O Block Contains up to Four IOEs
32
IO_dataina[3:0] IO_datainb[3:0]
io_clk[7..0]
I/O Block Local Interconnect
R4 & R24 Interconnects
LAB
LAB
LAB
LAB Local Interconnect
C4 & C16 Interconnects
Note to Figure 2-48:
(1) The 32 data and control signals consist of eight data out lines: four lines each for DDR applications io_dataouta[3..0] and io_dataoutb[3..0], four output enables io_oe[3..0], four input clock enables io_ce_in[3..0], four output clock enables io_ce_out[3..0], four clocks io_clk[3..0], four asynchronous clear and preset signals io_aclr/apreset[3..0], and four synchronous clear and preset signals io_sclr/spreset[3..0].
2-74 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
There are 32 control and data signals that feed each row or column I/O block. These control and data signals are driven from the logic array. The row or column IOE clocks, io_clk[7..0], provide a dedicated routing resource for low-skew, high-speed clocks. I/O clocks are generated from global or regional clocks (see the "PLLs & Clock Networks" section). Figure 2-49 illustrates the signal paths through the I/O block. Figure 2-49. Signal Path through the I/O Block
Row or Column io_clk[7..0]
To Other IOEs
To Logic Array
io_dataina io_datainb oe ce_in ce_out io_ce_in io_ce_out io_aclr Control Signal Selection aclr/apreset sclr/spreset clk_in io_sclr clk_out io_clk io_dataouta io_dataoutb IOE
io_oe
From Logic Array
Each IOE contains its own control signal selection for the following control signals: oe, ce_in, ce_out, aclr/apreset, sclr/spreset, clk_in, and clk_out. Figure 2-50 illustrates the control signal selection.
Altera Corporation March 2005
2-75 Stratix II Device Handbook, Volume 1
I/O Structure
Figure 2-50. Control Signal Selection per IOE
Dedicated I/O Clock [7..0] Local Interconnect Local Interconnect Local Interconnect Local Interconnect Local Interconnect Local Interconnect io_oe
io_sclr
io_aclr
io_ce_out
io_ce_in
io_clk
clk_out
ce_out
sclr/spreset
clk_in
ce_in
aclr/apreset
oe
Notes to Figure 2-50:
(1) Control signals ce_in, ce_out, aclr/apreset, sclr/spreset, and oe can be global signals even though their control selection multiplexers are not directly fed by the ioe_clk[7..0] signals. The ioe_clk signals can drive the I/O local interconnect, which then drives the control selection multiplexers.
In normal bidirectional operation, the input register can be used for input data requiring fast setup times. The input register can have its own clock input and clock enable separate from the OE and output registers. The output register can be used for data requiring fast clock-to-output performance. The OE register can be used for fast clock-to-output enable timing. The OE and output register share the same clock source and the same clock enable source from local interconnect in the associated LAB, dedicated I/O clocks, and the column and row interconnects. Figure 2-51 shows the IOE in bidirectional configuration.
2-76 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-51. Stratix II IOE in Bidirectional I/O Configuration Note (1)
ioe_clk[7..0] Column, Row, or Local Interconnect
oe OE Register
D Q
clkout
ENA CLRN/PRN OE Register tCO Delay VCCIO
ce_out
PCI Clamp (2)
VCCIO
aclr/apreset Chip-Wide Reset Output Register
D Q
Programmable Pull-Up Resistor
Output Pin Delay
On-Chip Termination
sclr/spreset
Drive Strength Control ENA Open-Drain Output CLRN/PRN Input Pin to Logic Array Delay
Input Pin to Input Register Delay
Input Register clkin
D Q
Bus-Hold Circuit
ce_in
ENA CLRN/PRN
Notes to Figure 2-51:
(1) (2) All input signals to the IOE can be inverted at the IOE. The optional PCI clamp is only available on column I/O pins.
The Stratix II device IOE includes programmable delays that can be activated to ensure input IOE register-to-logic array register transfers, input pin-to-logic array register transfers, or output IOE register-to-pin transfers.
Altera Corporation March 2005
2-77 Stratix II Device Handbook, Volume 1
I/O Structure
A path in which a pin directly drives a register may require the delay to ensure zero hold time, whereas a path in which a pin drives a register through combinational logic may not require the delay. Programmable delays exist for decreasing input-pin-to-logic-array and IOE input register delays. The Quartus II Compiler can program these delays to automatically minimize setup time while providing a zero hold time. Programmable delays can increase the register-to-pin delays for output and/or output enable registers. Programmable delays are no longer required to ensure zero hold times for logic array register-to-IOE register transfers. The Quartus II Compiler can create the zero hold time for these transfers. Table 2-15 shows the programmable delays for Stratix II devices.
Table 2-15. Stratix II Programmable Delay Chain Programmable Delays
Input pin to logic array delay Input pin to input register delay Output pin delay Output enable register tCO delay
Quartus II Logic Option
Input delay from pin to internal cells Input delay from pin to input register Delay from output register to output pin Delay to output enable pin
The IOE registers in Stratix II devices share the same source for clear or preset. The designer can program preset or clear for each individual IOE. The designer can also program the registers to power up high or low after configuration is complete. If programmed to power up low, an asynchronous clear can control the registers. If programmed to power up high, an asynchronous preset can control the registers. This feature prevents the inadvertent activation of another device's active-low input upon power-up. If one register in an IOE uses a preset or clear signal then all registers in the IOE must use that same signal if they require preset or clear. Additionally a synchronous reset signal is available to the designer for the IOE registers.
Double Data Rate I/O Pins
Stratix II devices have six registers in the IOE, which support DDR interfacing by clocking data on both positive and negative clock edges. The IOEs in Stratix II devices support DDR inputs, DDR outputs, and bidirectional DDR modes. When using the IOE for DDR inputs, the two input registers clock double rate input data on alternating edges. An input latch is also used in the IOE for DDR input acquisition. The latch holds the data that is present during the clock high times. This allows both bits of data to be synchronous with
2-78 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
the same clock edge (either rising or falling). Figure 2-52 shows an IOE configured for DDR input. Figure 2-53 shows the DDR input timing diagram. Figure 2-52. Stratix II IOE in DDR Input I/O Configuration Notes (1), (2), (3)
ioe_clk[7..0] Column, Row, or Local Interconnect To DQS Logic Block (3) VCCIO
PCI Clamp (4)
VCCIO
DQS Local Bus (2)
Programmable Pull-Up Resistor
Input Pin to Input RegisterDelay sclr/spreset Input Register
D Q
On-Chip Termination
clkin ce_in aclr/apreset
ENA CLRN/PRN
Bus-Hold Circuit
Chip-Wide Reset Input Register
D Q D
Latch
Q
ENA CLRN/PRN
ENA CLRN/PRN
Notes to Figure 2-52:
(1) (2) (3) (4) All input signals to the IOE can be inverted at the IOE. This signal connection is only allowed on dedicated DQ function pins. This signal is for dedicated DQS function pins only. The optional PCI clamp is only available on column I/O pins.
Altera Corporation March 2005
2-79 Stratix II Device Handbook, Volume 1
I/O Structure
Figure 2-53. Input Timing Diagram in DDR Mode
Data at input pin B0 A0 B1 A1 B2 A2 B3 A3 B4
CLK
A0
A1
A2
A3
Input To Logic Array
B0 B1 B2 B3
When using the IOE for DDR outputs, the two output registers are configured to clock two data paths from ALMs on rising clock edges. These output registers are multiplexed by the clock to drive the output pin at a x2 rate. One output register clocks the first bit out on the clock high time, while the other output register clocks the second bit out on the clock low time. Figure 2-54 shows the IOE configured for DDR output. Figure 2-55 shows the DDR output timing diagram.
2-80 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-54. Stratix II IOE in DDR Output I/O Configuration Notes (1), (2)
ioe_clk[7..0] Column, Row, or Local Interconnect
oe OE Register
D Q
clkout
ENA CLRN/PRN
ce_out
OE Register tCO Delay
aclr/apreset
VCCIO
PCI Clamp (3)
Chip-Wide Reset OE Register
D Q
VCCIO
sclr/spreset
ENA CLRN/PRN
Used for DDR, DDR2 SDRAM
Programmable Pull-Up Resistor
Output Register
D Q
Output Pin Delay clk Drive Strength Control Open-Drain Output
On-Chip Termination
ENA CLRN/PRN
Output Register
D Q
ENA CLRN/PRN
Bus-Hold Circuit
Notes to Figure 2-54:
(1) (2) (3) All input signals to the IOE can be inverted at the IOE. The tri-state buffer is active low. The DDIO megafunction represents the tri-state buffer as active-high with an inverter at the OE register data port. The optional PCI clamp is only available on column I/O pins.
Altera Corporation March 2005
2-81 Stratix II Device Handbook, Volume 1
I/O Structure
Figure 2-55. Output TIming Diagram in DDR Mode
CLK
A1
A2
A3
A4
From Internal Registers
B1 B2 B3 B4
DDR output
B1
A1
B2
A2
B3
A3
B4
A4
The Stratix II IOE operates in bidirectional DDR mode by combining the DDR input and DDR output configurations. The negative-edge-clocked OE register holds the OE signal inactive until the falling edge of the clock. This is done to meet DDR SDRAM timing requirements.
External RAM Interfacing
In addition to the six I/O registers in each IOE, Stratix II devices also have dedicated phase-shift circuitry for interfacing with external memory interfaces, including DDR and DDR2 SDRAM, QDR II SRAM, RLDRAM II, and SDR SDRAM. In every Stratix II device, the I/O banks at the top (banks 3 and 4) and bottom (banks 7 and 8) of the device support DQ and DQS signals with DQ bus modes of x4, x8/x9, x16/x18, or x32/x36. Table 2-16 shows the number of DQ and DQS buses that are supported per device. A compensated delay element on each DQS pin automatically aligns input DQS synchronization signals with the data window of their corresponding DQ data signals. The DQS signals drive a local DQS bus in the top and bottom I/O banks. This DQS bus is an additional resource to the I/O clocks and is used to clock DQ input registers with the DQS signal. The Stratix II device has two phase-shifting reference circuits, one on the top and one on the bottom of the device. The circuit on the top controls the compensated delay elements for all DQS pins on the top. The circuit on the bottom controls the compensated delay elements for all DQS pins on the bottom.
2-82 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Table 2-16. DQS & DQ Bus Mode Support Device
EP2S15
Notes (1) Number of x8/x9 Groups
4 8 4 8 4 8 18 (4) (4) 18 18 (4) 18 18 18 18
Package
484-pin FineLine BGA 672-pin FineLine BGA (2)
Number of x4 Groups
8 18 8 18 8 18 36 (4) (4) 36 36 (4) 36 36 36 36
Number of Number of x16/x18 Groups x32/x36 Groups
0 4 0 4 0 4 8 (4) (4) 8 8 (4) 8 8 8 8 0 0 0 0 0 0 4 (4) (4) 4 4 (4) 4 4 4 4
EP2S30
484-pin FineLine BGA 672-pin FineLine BGA (2)
EP2S60
484-pin FineLine BGA 672-pin FineLine BGA (2) 1,020-pin FineLine BGA (3)
EP2S90
484-pin Hybrid FineLine BGA 780-pin FineLine BGA 1,020-pin FineLine BGA (3) 1,508-pin FineLine BGA (3)
EP2S130 780-pin FineLine BGA 1,020-pin FineLine BGA (3) 1,508-pin FineLine BGA (3) EP2S180 1,020-pin FineLine BGA (3) 1,508-pin FineLine BGA (3) Notes to Table 2-16:
(1) (2) (3) (4)
Numbers are preliminary until devices are available. These device and package combinations can support one 72-bit DIMM in x4 mode or one 64-bit DIMM in x8/x9 mode. These device and package combinations can support two 64- or 72-bit DIMMs in x4 and x8/x9 modes. The number of DQ and DQS buses will be updated in the next version of the Stratix II Device Handbook.
Each phase-shifting reference circuit is driven by a system reference clock, which must have the same frequency as the DQS signal. Clock pins CLK[15..12]p feed the phase circuitry on the top of the device and clock pins CLK[7..4]p feed the phase circuitry on the bottom of the device. In addition, PLL clock outputs can also feed the phase-shifting reference circuits. Figure 2-56 illustrates the phase-shift reference circuit control of each DQS delay shift on the top of the device. This same circuit is duplicated on the bottom of the device.
Altera Corporation March 2005
2-83 Stratix II Device Handbook, Volume 1
I/O Structure
Figure 2-56. DQS Phase-Shift Circuitry Notes (1), (2), (3), (4)
From PLL 5 (3) DQSn Pin DQS Pin DQSn Pin DQS Pin CLK[15..12]p (2) DQS Pin DQSn Pin DQS Pin DQSn Pin
t
t
t
t
DQS Phase-Shift Circuitry
t
t
t
t
DQS Logic Blocks
to IOE
to IOE
to IOE
to IOE
to IOE
to IOE
to IOE
to IOE
Notes to Figure 2-56:
(1) (2) (3) There are up to 18 pairs of DQS and DQSn pins available on the top or the bottom of the Stratix II device. There are up to 10 pairs on the right side and 8 pairs on the left side of the DQS phase-shift circuitry. The t module represents the DQS logic block. Clock pins CLK[15..12]p feed the phase-shift circuitry on the top of the device and clock pins CLK[7..4]p feed the phase circuitry on the bottom of the device. You can also use a PLL clock output as a reference clock to the phaseshift circuitry. You can only use PLL 5 to feed the DQS phase-shift circuitry on the top of the device and PLL 6 to feed the DQS phase-shift circuitry on the bottom of the device.
(4)
These dedicated circuits combined with enhanced PLL clocking and phase-shift ability provide a complete hardware solution for interfacing to high-speed memory.
f
For more information on external memory interfaces, refer to the External Memory Interfaces in Stratix II Devices chapter in Volume 2 of the Stratix II Device Handbook.
Programmable Drive Strength
The output buffer for each Stratix II device I/O pin has a programmable drive strength control for certain I/O standards. The LVTTL, LVCMOS, SSTL, and HSTL standards have several levels of drive strength that the user can control. The default setting used in the Quartus II software is the maximum current strength setting that is used to achieve maximum I/O performance. For all I/O standards, the minimum setting is the lowest drive strength that guarantees the IOH/IOL of the standard. Using minimum settings provides signal slew rate control to reduce system noise and signal overshoot.
2-84 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Table 2-17 shows the possible settings for the I/O standards with drive strength control.
Table 2-17. Programmable Drive Strength Note (1) I/O Standard
3.3-V LVTTL 3.3-V LVCMOS 2.5-V LVTTL/LVCMOS 1.8-V LVTTL/LVCMOS 1.5-V LVCMOS SSTL-2 class I SSTL-2 class II SSTL-18 class I SSTL-18 class II HSTL-18 class I HSTL-18 class II HSTL-15 class I HSTL-15 class II Note to Table 2-17:
(1) The Quartus II software default current setting is the maximum setting for each I/O standard.
IOH / IOL Current Strength Setting (mA) for Column I/O Pins
24, 20, 16, 12, 8, 4 24, 20, 16, 12, 8, 4 16, 12, 8, 4 12, 10, 8, 6, 4, 2 8, 6, 4, 2 12, 8 24, 20, 16 12, 10, 8, 6, 4 20, 18, 16, 8 12, 10, 8, 6, 4 20, 18, 16 12, 10, 8, 6, 4 20, 18, 16
IOH / IOL Current Strength Setting (mA) for Row I/O Pins
12, 8, 4 8, 4 12, 8, 4 8, 6, 4, 2 4, 2 12, 8 16 10, 8, 6, 4 -
Open-Drain Output
Stratix II devices provide an optional open-drain (equivalent to an opencollector) output for each I/O pin. This open-drain output enables the device to provide system-level control signals (e.g., interrupt and writeenable signals) that can be asserted by any of several devices.
Bus Hold
Each Stratix II device I/O pin provides an optional bus-hold feature. The bus-hold circuitry can weakly hold the signal on an I/O pin at its lastdriven state. Since the bus-hold feature holds the last-driven state of the pin until the next input signal is present, you do not need an external pullup or pull-down resistor to hold a signal level when the bus is tri-stated.
Altera Corporation March 2005
2-85 Stratix II Device Handbook, Volume 1
I/O Structure
The bus-hold circuitry also pulls undriven pins away from the input threshold voltage where noise can cause unintended high-frequency switching. The designer can select this feature individually for each I/O pin. The bus-hold output will drive no higher than VCCIO to prevent overdriving signals. If the bus-hold feature is enabled, the programmable pull-up option cannot be used. Disable the bus-hold feature when the I/O pin has been configured for differential signals. The bus-hold circuitry uses a resistor with a nominal resistance (RBH) of approximately 7 k to weakly pull the signal level to the last-driven state. See the DC & Switching Characteristics chapter in the Stratix II Device Handbook, Volume 1, for the specific sustaining current driven through this resistor and overdrive current used to identify the next-driven input level. This information is provided for each VCCIO voltage level. The bus-hold circuitry is active only after configuration. When going into user mode, the bus-hold circuit captures the value on the pin present at the end of configuration.
Programmable Pull-Up Resistor
Each Stratix II device I/O pin provides an optional programmable pullup resistor during user mode. If you enable this feature for an I/O pin, the pull-up resistor (typically 25 k) weakly holds the output to the VCCIO level of the output pin's bank.
Advanced I/O Standard Support
Stratix II device IOEs support the following I/O standards:

3.3-V LVTTL/LVCMOS 2.5-V LVTTL/LVCMOS 1.8-V LVTTL/LVCMOS 1.5-V LVCMOS 3.3-V PCI 3.3-V PCI-X mode 1 LVDS LVPECL (on input and output clocks only) HyperTransport technology Differential 1.5-V HSTL class I and II Differential 1.8-V HSTL class I and II Differential SSTL-18 class I and II Differential SSTL-2 class I and II 1.5-V HSTL class I and II 1.8-V HSTL class I and II SSTL-2 class I and II SSTL-18 class I and II
2-86 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Table 2-18 describes the I/O standards supported by Stratix II devices.
Table 2-18. Stratix II Supported I/O Standards I/O Standard
LVTTL LVCMOS 2.5 V 1.8 V 1.5-V LVCMOS 3.3-V PCI 3.3-V PCI-X mode 1 LVDS LVPECL (1)
Type
Single-ended Single-ended Single-ended Single-ended Single-ended Single-ended Single-ended Differential Differential
Input Reference Output Supply Board Termination Voltage (VREF) (V) Voltage (VCCIO) (V) Voltage (VTT) (V)
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 0.75 0.90 0.90 1.25 0.75 0.9 0.90 1.25 3.3 3.3 2.5 1.8 1.5 3.3 3.3 2.5 (3) 3.3 2.5 (3) 1.5 1.8 1.8 2.5 1.5 1.8 1.8 2.5 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 0.75 0.90 0.90 1.25 0.75 0.9 0.90 1.25
HyperTransport technology Differential Differential 1.5-V HSTL class I and II (2) Differential 1.8-V HSTL class I and II (2) Differential Differential
Differential SSTL-18 class I Differential and II (2) Differential SSTL-2 class I and II (2) 1.5-V HSTL class I and II 1.8-V HSTL class I and II SSTL-18 class I and II SSTL-2 class I and II Notes to Table 2-18:
(1) (2) (3)
Differential Voltage-referenced Voltage-referenced Voltage-referenced Voltage-referenced
This I/O standard is only available on input and output column clock pins. This I/O standard is only available on input clock pins and DQS pins in I/O banks 3, 4, 7, and 8, and output clock pins in I/O banks 9,10, 11, and 12. VCCIO is 3.3 V when using this I/O standard in input and output column clock pins (in I/O banks 3, 4, 7, 8, 9, 10, 11, and 12).
f
For more information on I/O standards supported by Stratix II I/O banks, refer to the Selectable I/O Standards in Stratix II Devices chapter in Volume 2 of the Stratix II Device Handbook. Stratix II devices contain eight I/O banks and four enhanced PLL external clock output banks, as shown in Figure 2-57. The four I/O banks on the right and left of the device contain circuitry to support high-speed
Altera Corporation March 2005
2-87 Stratix II Device Handbook, Volume 1
I/O Structure
differential I/O for LVDS and HyperTransport inputs and outputs. These banks support all Stratix II I/O standards except PCI or PCI-X I/O pins, and SSTL-18 class II and HSTL outputs. The top and bottom I/O banks support all single-ended I/O standards. Additionally, enhanced PLL external clock output banks allow clock output capabilities such as differential support for SSTL and HSTL.
2-88 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Figure 2-57. Stratix II I/O Banks Notes (1), (2), (3), (4)
DQS8T VREF0B3 DQS7T VREF1B3 DQS6T VREF3B3 DQS5T VREF4B3 VREF2B3
PLL11
Bank 11
PLL5
Bank 9
DQS4T VREF0B4
DQS3T VREF1B4
DQS2T VREF2B4
DQS1T VREF3B4
DQS0T VREF4B4
PLL7 Bank 3
VREF 4B2
PLL10 Bank 4
VREF 0B5
This I/O bank supports LVDS, HyperTransport and LVPECL standards for input clock operations. Differential HSTL and differential SSTL standards are supported for both input and output operations.
VR EF1B2
VREF 0B2
PLL1
PLL2
VR EF4B1
I/O banks 1, 2, 5 & 6 support LVTTL, LVCMOS, 2.5-V, 1.8-V, 1.5-V, SSTL-2, SSTL-18 Class I, LVDS, HyperTransport, differential SSTL-2 and differential SSTL-18 Class I standards for both input and output operations. HSTL, SSTL-18 Class II, differential HSTL and differential SSTL-18 Class II standards are only supported for input operations.
PLL4
PLL3
VR EF0B6
VR EF3B1
This I/O bank supports LVDS, HyperTransport and LVPECL standards for input clock operations. Differential HSTL and differential SSTL standards are supported for both input and output operations.
I/O banks 7, 8, 10 & 12 support all single-ended I/O standards for both input and output operations. All differential I/O standards are supported for both input and output operations at I/O banks 10 & 12.
This I/O bank supports LVDS, HyperTransport and LVPECL standards for input clock operations. Differential HSTL and differential SSTL standards are supported for both input and output operations.
Bank 1
Bank 6
PLL9
VREF 2B1
VREF 1B1
VREF 0B1
Bank 8 PLL8
VREF4B8 DQS8B VREF3B8 VREF2B8 VREF1B8 VREF0B8 DQS5B DQS7B DQS6B
Bank 12
Bank 10
VREF4B7 DQS4B VREF3B7 DQS3B
Bank 7
VREF2B7 DQS2B VREF1B7 DQS1B VREF0B7 DQS0B
PLL12
PLL6
Notes to Figure 2-57:
(1) (2) (3) (4) Figure 2-57 is a top view of the silicon die which corresponds to a reverse view for flip-chip packages. It is a graphical representation only. Depending on size of the device, different device members have different number of VREF groups. Refer to the pin list and the Quartus II software for exact locations. Banks 9 through 12 are enhanced PLL external clock output banks. Horizontal I/O banks feature SERDES and DPA circuitry for high speed differential I/O standards. See the High Speed Differential I/O Interfaces in Stratix II Devices chapter in the Stratix II Device Handbook, Volume 2 for more information on differential I/O standards.
Each I/O bank has its own VCCIO pins. A single device can support 1.5-, 1.8-, 2.5-, and 3.3-V interfaces; each bank can support a different VCCIO level independently. Each bank also has dedicated VREF pins to support the voltage-referenced standards (such as SSTL-2).
Altera Corporation March 2005
2-89 Stratix II Device Handbook, Volume 1
VREF 4B6
VREF 3B6
VREF 2B6
VR EF1B6
VREF 4B5
VR EF3B5
I/O banks 3, 4, 9 & 11 support all single-ended I/O standards for both input and output operations. All differential I/O standards are supported for both input and output operations at I/O banks 9 & 11.
This I/O bank supports LVDS, HyperTransport and LVPECL standards for input clock operations. Differential HSTL and differential SSTL standards are supported for both input and output operations.
VR EF3B 2
Bank 2
Bank 5
VR EF2B2
VR EF2B5
VR EF1B 5
I/O Structure
Each I/O bank can support multiple standards with the same VCCIO for input and output pins. Each bank can support one VREF voltage level. For example, when VCCIO is 3.3 V, a bank can support LVTTL, LVCMOS, and 3.3-V PCI for inputs and outputs.
On-Chip Termination
Stratix II devices provide differential (for the LVDS or HyperTransport technology I/O standard) and series on-chip termination to reduce reflections and maintain signal integrity. On-chip termination simplifies board design by minimizing the number of external termination resistors required. Termination can be placed inside the package, eliminating small stubs that can still lead to reflections. Stratix II devices provide three types of termination:

Differential termination (RD) Series termination (RS) without calibration Series termination (RS) with calibration
Table 2-19 shows the Stratix II on-chip termination support per I/O bank.
Table 2-19. On-Chip Termination Support by I/O Banks On-Chip Termination Support
Series termination without calibration
I/O Standard Support
3.3-V LVTTL 3.3-V LVCMOS 2.5-V LVTTL 2.5-V LVCMOS 1.8-V LVTTL 1.8-V LVCMOS 1.5-V LVTTL 1.5-V LVCMOS SSTL-2 class I and II SSTL-18 class I and II 1.8-V HSTL class I 1.8-V HSTL class II 1.5-V HSTL class I
Top & Bottom Banks (3, 4, 7 & 8) v v v v v v v v v v v v v
Left & Right Banks (1, 2, 5 & 6) v v v v v v
v v(1)
2-90 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Table 2-19. On-Chip Termination Support by I/O Banks On-Chip Termination Support
Series termination with calibration
I/O Standard Support
3.3-V LVTTL 3.3-V LVCMOS 2.5-V LVTTL 2.5-V LVCMOS 1.8-V LVTTL 1.8-V LVCMOS 1.5-V LVTTL (2) 1.5-V LVCMOS (2) SSTL-2 class I and II SSTL-18 class I and II 1.8-V HSTL class I 1.8-V HSTL class II 1.5-V HSTL class I
Top & Bottom Banks (3, 4, 7 & 8) v v v v v v v v v v v v v v v
Left & Right Banks (1, 2, 5 & 6)
Differential termination (2)
LVDS HyperTransport technology
Notes to Table 2-19:
(1) Clock pins CLK1, CLK3, CLK9, CLK11, and pins FPLL[7..10]CLK do not support differential on-chip termination. Clock pins CLK0, CLK2, CLK8, and CLK10 do support differential on-chip termination. Clock pins in the top and bottom banks (CLK[4..7, 12..15]) do not support differential on-chip termination. The I/O pins in the left and right banks do not support the SSTL-18 class II output standard.
(2)
Differential On-Chip Termination
Stratix II devices support internal differential termination with a nominal resistance value of 100 for LVDS or HyperTransport technology input receiver buffers. LVPECL input signals (supported on clock pins only) require an external termination resistor. Differential on-chip termination is supported across the full range of supported differential data rates as shown in the High-Speed I/O Specifications section of the DC & Switching Characteristics chapter in Volume 1 of the Stratix II Device Handbook.
f
For more information on differential on-chip termination, refer to the High-Speed Differential I/O Interfaces with DPA in Stratix II Devices in Volume 2 of the Stratix II Device Handbook.
Altera Corporation March 2005
2-91 Stratix II Device Handbook, Volume 1
I/O Structure
For more information on tolerance specifications for differential on-chip termination, refer to the DC & Switching Characteristics chapter in Volume 1 of the Stratix II Device Handbook.
On-Chip Series Termination without Calibration
Stratix II devices support driver impedance matching to provide the I/O driver with controlled output impedance that closely matches the impedance of the transmission line. As a result, reflections can be significantly reduced. Stratix II devices support on-chip series termination for single-ended I/O standards with typical RS values of 25 and 50. Once matching impedance is selected, current drive strength is no longer selectable. Table 2-19 shows the list of output standards that support on-chip series termination without calibration.
f
For more information on series on-chip termination supported by Stratix II devices, refer to the Selectable I/O Standards in Stratix II Devices chapter in Volume 2 of the Stratix II Device Handbook. For more information on tolerance specifications for on-chip termination without calibration, refer to the DC & Switching Characteristics chapter in Volume 1 of the Stratix II Device Handbook.
On-Chip Series Termination with Calibration
Stratix II devices support on-chip series termination with calibration in column I/Os in top and bottom banks. There is one calibration circuit for the top I/O banks and one circuit for the bottom I/O banks. Each on-chip series termination calibration circuit compares the total impedance of each I/O buffer to the external 25- or 50- resistors connected to the RUP and RDN pins, and dynamically enables or disables the transistors until they match. Calibration occurs at the end of device configuration. Once the calibration circuit finds the correct impedance, it powers down and stops changing the characteristics of the drivers.
f
For more information on series on-chip termination supported by Stratix II devices, refer to the Selectable I/O Standards in Stratix II Devices chapter in Volume 2 of the Stratix II Device Handbook.
2-92 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
For more information on tolerance specifications for on-chip termination with calibration, refer to the DC & Switching Characteristics chapter in Volume 1 of the Stratix II Device Handbook.
MultiVolt I/O Interface
The Stratix II architecture supports the MultiVolt I/O interface feature that allows Stratix II devices in all packages to interface with systems of different supply voltages. The Stratix II VCCINT pins must always be connected to a 1.2-V power supply. With a 1.2-V VCCINT level, input pins are 1.5-, 1.8-, 2.5-, and 3.3-V tolerant. The VCCIO pins can be connected to either a 1.5-, 1.8-, 2.5-, or 3.3-V power supply, depending on the output requirements. The output levels are compatible with systems of the same voltage as the power supply (for example, when VCCIO pins are connected to a 1.5-V power supply, the output levels are compatible with 1.5-V systems). The Stratix II VCCPD power pins must be connected to a 3.3-V power supply. These power pins are used to supply the pre-driver power to the output buffers, which increases the performance of the output pins. The VCCPD pins also power configuration input pins and JTAG input pins. Table 2-20 summarizes Stratix II MultiVolt I/O support.
Table 2-20. Stratix II MultiVolt I/O Support Note (1) Input Signal (V) VCCIO (V)
1.5 1.8 2.5 3.3 Notes to Table 2-20:
(1) (2) (3) To drive inputs higher than VCCIO but less than 4.0 V, disable the PCI clamping diode and select the Allow LVTTL and LVCMOS input levels to overdrive input buffer option in the Quartus II software. The pin current may be slightly higher than the default value. Although VCCIO specifies the voltage necessary for the Stratix II device to drive out, a receiving device powered at a different level can still interface with the Stratix II device if it has inputs that tolerate the VCCIO value.
Output Signal (V) 3.3 v (2) v (2) v v 1.5 v v (3) v (3) v (3) v v (3) v (3) v v (3) v v 1.8 2.5 3.3 5.0
1.5 v v (2)
1.8 v v
2.5 v (2) v (2) v v (2)
The TDO and nCEO pins are powered by VCCIO of the bank that they reside in. TDO is in I/O bank 4 and nCEO is in I/O bank 7.
Altera Corporation March 2005
2-93 Stratix II Device Handbook, Volume 1
I/O Structure
Ideally, the VCC supplies for the I/O buffers of any two connected pins are at the same voltage level. This may not always be possible depending on the VCCIO level of TDO and nCEO pins on master devices and the configuration voltage level chosen by VCCSEL on slave devices. Master and slave devices can be in any position in the chain. Master indicates that it is driving out TDO or nCEO to a slave device. For multi-device passive configuration schemes, the nCEO pin of the master device will be driving the nCE pin of the slave device. The VCCSEL pin on the slave device selects which input buffer is used for nCE. When VCCSEL is logic high, it selects the 1.8-V/1.5-V buffer powered by VCCIO. When VCCSEL is logic low it selects the 3.3-V/2.5-V input buffer powered by VCCPD. The ideal case is to have the VCCIO of the nCEO bank in a master device match the VCCSEL settings for the nCE input buffer of the slave device it is connected to, but that may not be possible depending on the application. Table 2-21 contains board design recommendations to ensure that nCEO can successfully drive nCE for all power supply combinations.
Table 2-21. Board Design Recommendations for nCEO Stratix II nCEO VCCIO Voltage Level in I/O Bank 7 nCE Input Buffer Power VC C I O = 3.3 V
VCCSEL high (VC C I O = 1.5 V) VCCSEL high (VC C I O = 1.8 V) VCCSEL low (VC C P D = 3.3 V)
Notes to Table 2-21:
(1) (2) (3) (4) (5) (6) Input buffer is 3.3-V tolerant. The nCEO output buffer meets VO H (MIN) = 2.4 V. Input buffer is 2.5-V tolerant. The nCEO output buffer meets VOH (MIN) = 2.0 V. Input buffer is 1.8-V tolerant. An external 250- pull-up resistor is not required, but recommended if signal levels on the board are not optimal.
VC C I O = 2.5 V v (3), (4) v (3), (4) v (4)
VC C I O = 1.8 V v (5) v v (6)
VC C I O = 1.5 V v v
Level shifter required
v(1), (2) v (1), (2) v
For JTAG chains, the TDO pin of the first device will be driving the TDI pin of the second device in the chain. The VCCSEL input on JTAG input I/O cells (TCK, TMS, TDI, and TRST) is internally hardwired to GND selecting the 3.3-V/2.5-V input buffer powered by VCCPD. The ideal case is to have the VCCIO of the TDO bank from the first device to match the VCCSEL settings for TDI on the second device, but that may not be possible depending on the application. Table 2-22 contains board design recommendations to ensure proper JTAG chain operation.
2-94 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Table 2-22. Supported TDO/TDI Voltage Combinations Device
Stratix II Non-Stratix II
TDI Input Buffer Power
Always VC C P D (3.3V) VCC = 3.3 V VCC = 2.5 V VCC = 1.8 V VCC = 1.5 V
Stratix II TDO VC C I O Voltage Level in I/O Bank 4 VC C I O = 3.3 V v (1) v (1) v (1), (4) v (1), (4) v (1), (4) VC C I O = 2.5 V v (2) v (2) v (2) v (2), (5) v (2), (5) VC C I O = 1.8 V v (3) v (3) v (3) v v (6) VC C I O = 1.5 V
Level shifter required Level shifter required Level shifter required Level shifter required
v
Notes to Table 2-22:
(1) (2) (3) (4) (5) (6) The TDO output buffer meets VOH (MIN) = 2.4 V. The TDO output buffer meets VOH (MIN) = 2.0 V. An external 250- pull-up resistor is not required, but recommended if signal levels on the board are not optimal. Input buffer must be 3.3-V tolerant. Input buffer must be 2.5-V tolerant. Input buffer must be 1.8-V tolerant.
High-Speed Differential I/O with DPA Support
Stratix II devices contain dedicated circuitry for supporting differential standards at speeds up to 1 Gbps. The LVDS and HyperTransport differential I/O standards are supported in the Stratix II device. In addition, the LVPECL I/O standard is supported on input and output clock pins on the top and bottom I/O banks. The high-speed differential I/O circuitry supports the following high speed I/O interconnect standards and applications:

SPI-4 Phase 2 (POS-PHY Level 4) SFI-4 Parallel RapidIO HyperTransport technology
There are four dedicated high-speed PLLs in the EP2S15 to EP2S30 devices and eight dedicated high-speed PLLs in the EP2S60 to EP2S180 devices to multiply reference clocks and drive high-speed differential SERDES channels. Tables 2-23 through 2-28 show the number of channels that each fast PLL can clock in each of the Stratix II devices. In Tables 2-23 through 2-28 the first row for each transmitter or receiver provides the number of channels driven directly by the PLL. The second row below it shows the maximum
Altera Corporation March 2005
2-95 Stratix II Device Handbook, Volume 1
High-Speed Differential I/O with DPA Support
channels a PLL can drive if cross bank channels are used from the adjacent center PLL. For example, in the 484-pin FineLine BGA EP2S15 device, PLL 1 can drive a maximum of 10 transmitter channels in I/O bank 1 or a maximum of 19 transmitter channels in I/O banks 1 and 2. The Quartus II software may also merge receiver and transmitter PLLs when a receiver is driving a transmitter. In this case, one fast PLL can drive both the maximum numbers of receiver and transmitter channels.
Table 2-23. EP2S15 Device Differential Channels Package
484-pin FineLine BGA
Note (1) Center Fast PLLs PLL 1
10 19 11 21 10 19 11 21
Transmitter/ Receiver
Transmitter
Total Channels
38 (2) (3)
PLL 2
9 19 10 21 9 19 10 21
PLL 3
9 19 10 21 9 19 10 21
PLL 4
10 19 11 21 10 19 11 21
Receiver
42 (2) (3)
672-pin FineLine BGA
Transmitter
38 (2) (3)
Receiver
42 (2) (3)
Table 2-24. EP2S30 Device Differential Channels Package
484-pin FineLine BGA
Note (1) Center Fast PLLs PLL 1
10 19 11 21 16 29 17 31
Transmitter/ Receiver
Transmitter
Total Channels
38 (2) (3)
PLL 2
9 19 10 21 13 29 14 31
PLL 3
9 19 10 21 13 29 14 31
PLL 4
10 19 11 21 16 29 17 31
Receiver
42 (2) (3)
672-pin FineLine BGA
Transmitter
58 (2) (3)
Receiver
62 (2) (3)
2-96 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Table 2-25. EP2S60 Differential Channels Package
484-pin FineLine BGA
Note (1) Corner Fast PLLs (4) PLL 7
10 11 16 17 21 21 -
Center Fast PLLs Transmitter/ Total Receiver Channels PLL 1 PLL 2 PLL 3 PLL 4
Transmitter 38 (2) (3) Receiver 42 (2) (3) 10 19 11 21 16 29 17 31 21 42 21 42 9 19 10 21 13 29 14 31 21 42 21 42 9 19 10 21 13 29 14 31 21 42 21 42 10 19 11 21 16 29 17 31 21 42 21 42
PLL 8
9 10 13 14 21 21 -
PLL 9 PLL 10
9 10 13 14 21 21 10 11 16 17 21 21 -
672-pin FineLine BGA
Transmitter
58 (2) (3)
Receiver
62 (2) (3)
1,020-pin FineLine BGA
Transmitter
84 (2) (3)
Receiver
84 (2) (3)
Table 2-26. EP2S90 Differential Channels Package
Note (1) Corner Fast PLLs (4) PLL 7
23 23 30 30 -
Center Fast PLLs Transmitter/ Total Receiver Channels PLL 1 PLL 2 PLL 3 PLL 4
38 (2) (3) 42 (2) (3) 10 19 11 21 16 32 17 34 23 45 23 46 30 59 30 59 9 19 10 21 16 32 17 34 22 45 24 46 29 59 29 59 9 19 10 21 16 32 17 34 22 45 24 46 29 59 29 59 10 19 11 21 16 32 17 34 23 45 23 46 30 59 30 59
PLL 8
22 24 29 29 -
PLL 9 PLL 10
22 24 29 29 23 23 30 30 -
484-pin Hybrid Transmitter FineLine BGA Receiver
780-pin FineLine BGA
Transmitter
64 (2) (3)
Receiver
68 (2) (3)
1,020-pin FineLine BGA
Transmitter
90 (2) (3)
Receiver
94 (2) (3)
1,508-pin FineLine BGA
Transmitter
118 (2) (3)
Receiver
118 (2) (3)
Altera Corporation March 2005
2-97 Stratix II Device Handbook, Volume 1
High-Speed Differential I/O with DPA Support
Table 2-27. EP2S130 Differential Channels Package
780-pin FineLine BGA
Note (1) Corner Fast PLLs (4) PLL 7
22 23 37 37 -
Center Fast PLLs Transmitter/ Total Receiver Channels PLL 1 PLL 2 PLL 3 PLL 4
Transmitter 64 (2) (3) Receiver 68 (2) (3) 16 32 17 34 22 44 23 46 37 78 37 78 16 32 17 34 22 44 23 46 41 78 41 78 16 32 17 34 22 44 23 46 41 78 41 78 16 32 17 34 22 44 23 46 37 78 37 78
PLL 8
22 23 41 41 -
PLL 9 PLL 10
22 23 41 41 22 23 37 37 -
1,020-pin FineLine BGA
Transmitter
88 (2) (3)
Receiver
92 (2) (3)
1,508-pin FineLine BGA
Transmitter
156 (2) (3)
Receiver
156 (2) (3)
Table 2-28. EP2S180 Differential Channels Package
1,020-pin FineLine BGA
Note (1) Corner Fast PLLs (4) PLL 7
22 23 37 37 -
Center Fast PLLs Transmitter/ Total Receiver Channels PLL 1 PLL 2 PLL 3 PLL 4
Transmitter 88 (2) (3) Receiver 92 (2) (3) 22 44 23 46 37 78 37 78 22 44 23 46 41 78 41 78 22 44 23 46 41 78 41 78 22 44 23 46 37 78 37 78
PLL 8
22 23 41 41 -
PLL 9 PLL 10
22 23 41 41 22 23 37 37 -
1,508-pin FineLine BGA
Transmitter
156 (2) (3)
Receiver
156 (2) (3)
Notes to Tables 2-23 to 2-28:
(1) (2) (3) (4) The total number of receiver channels includes the four non-dedicated clock channels that can be optionally used as data channels. This is the maximum number of channels the PLLs can directly drive. This is the maximum number of channels if the device uses cross bank channels from the adjacent center PLL. The channels accessible by the center fast PLL overlap with the channels accessible by the corner fast PLL. Therefore, the total number of channels is not the addition of the number of channels accessible by PLLs 1, 2, 3, and 4 with the number of channels accessible by PLLs 7, 8, 9, and 10.
2-98 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
Stratix II Architecture
Dedicated Circuitry with DPA Support
Stratix II devices support source-synchronous interfacing with LVDS or HyperTransport signaling at up to 1 Gbps. Stratix II devices can transmit or receive serial channels along with a low-speed or high-speed clock. The receiving device PLL multiplies the clock by an integer factor W = 1 through 32. For example, a HyperTransport technology application where the data rate is 1,000 Mbps and the clock rate is 500 MHz would require that W be set to 2. The SERDES factor J determines the parallel data width to deserialize from receivers or to serialize for transmitters. The SERDES factor J can be set to 4, 5, 6, 7, 8, 9, or 10 and does not have to equal the PLL clock-multiplication W value. A design using the dynamic phase aligner also supports all of these J factor values. For a J factor of 1, the Stratix II device bypasses the SERDES block. For a J factor of 2, the Stratix II device bypasses the SERDES block, and the DDR input and output registers are used in the IOE. Figure 2-58 shows the block diagram of the Stratix II transmitter channel. Figure 2-58. Stratix II Transmitter Channel
Data from R4, R24, C4, or direct link interconnect
+ - 10 10
Up to 1 Gbps
Local Interconnect
Dedicated Transmitter Interface
diffioclk refclk Fast PLL load_en Regional or global clock
Each Stratix II receiver channel features a DPA block for phase detection and selection, a SERDES, a synchronizer, and a data realigner circuit. You can bypass the dynamic phase aligner without affecting the basic sourcesynchronous operation of the channel. In addition, you can dynamically switch between using the DPA block or bypassing the block via a control signal from the logic array. Figure 2-59 shows the block diagram of the Stratix II receiver channel.
Altera Corporation March 2005
2-99 Stratix II Device Handbook, Volume 1
High-Speed Differential I/O with DPA Support
Figure 2-59. Stratix II Receiver Channel
Data to R4, R24, C4, or direct link interconnect Up to 1 Gbps
+ - D Q
Data Realignment Circuitry
10
data
retimed_data DPA DPA_clk Synchronizer
Dedicated Receiver Interface
Eight Phase Clocks
8
diffioclk refclk Fast PLL load_en Regional or global clock
An external pin or global or regional clock can drive the fast PLLs, which can output up to three clocks: two multiplied high-speed clocks to drive the SERDES block and/or external pin, and a low-speed clock to drive the logic array. In addition, eight phase-shifted clocks from the VCO can feed to the DPA circuitry. For more information on the fast PLL, see the PLLs in Stratix II Devices chapter in the Stratix II Handbook, Volume 2. The eight phase-shifted clocks from the fast PLL feed to the DPA block. The DPA block selects the closest phase to the center of the serial data eye to sample the incoming data. This allows the source-synchronous circuitry to capture incoming data correctly regardless of the channel-tochannel or clock-to-channel skew. The DPA block locks to a phase closest to the serial data phase. The phase-aligned DPA clock is used to write the data into the synchronizer. The synchronizer sits between the DPA block and the data realignment and SERDES circuitry. Since every channel utilizing the DPA block can have a different phase selected to sample the data, the synchronizer is needed to synchronize the data to the high-speed clock domain of the data realignment and the SERDES circuitry. For high-speed source synchronous interfaces such as POS-PHY 4, Parallel RapidIO, and HyperTransport, the source synchronous clock rate is not a byte- or SERDES-rate multiple of the data rate. Byte alignment is necessary for these protocols since the source synchronous clock does not provide a byte or word boundary since the clock is one half the data rate, not one eighth. The Stratix II device's high-speed differential I/O
2-100 Stratix II Device Handbook, Volume 1 Altera Corporation March 2005
Stratix II Architecture
circuitry provides dedicated data realignment circuitry for usercontrolled byte boundary shifting. This simplifies designs while saving ALM resources. The designer can use an ALM-based state machine to signal the shift of receiver byte boundaries until a specified pattern is detected to indicate byte alignment.
Fast PLL & Channel Layout
The receiver and transmitter channels are interleaved such that each I/O bank on the left and right side of the device has one receiver channel and one transmitter channel per LAB row. Figure 2-60 shows the fast PLL and channel layout in the EP2S15 and EP2S30 devices. Figure 2-61 shows the fast PLL and channel layout in the EP2S60 to EP2S180 devices. Figure 2-60. Fast PLL & Channel Layout in the EP2S15 & EP2S30 Devices Note (1)
4 LVDS Clock 4 2 Fast PLL 1 Fast PLL 4 2 DPA Clock Quadrant Quadrant DPA Clock LVDS Clock 4
4
2
Fast PLL 2
Fast PLL 3
2
4
LVDS Clock
DPA Clock
Quadrant
Quadrant
DPA Clock
LVDS Clock
4
Note to Figure 2-60:
(1) See Table 2-23 for the number of channels each device supports.
Altera Corporation March 2005
2-101 Stratix II Device Handbook, Volume 1
High-Speed Differential I/O with DPA Support
Figure 2-61. Fast PLL & Channel Layout in the EP2S60 to EP2S180 Devices Note (1)
Fast PLL 7 2 4 LVDS Clock 4 2 Fast PLL 1 Fast PLL 4 2 DPA Clock Quadrant Quadrant DPA Clock LVDS Clock 4 Fast PLL 10 2
4
2
Fast PLL 2
Fast PLL 3
2
4
LVDS Clock
DPA Clock
Quadrant
Quadrant
DPA Clock
LVDS Clock
4
2 Fast PLL 8 Fast PLL 9
2
Note to Figure 2-61:
(1) See Tables 2-24 through 2-28 for the number of channels each device supports.
2-102 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
3. Configuration & Testing
SII51003-2.1
IEEE Std. 1149.1 JTAG BoundaryScan Support
All Stratix(R) II devices provide Joint Test Action Group (JTAG) boundary-scan test (BST) circuitry that complies with the IEEE Std. 1149.1. JTAG boundary-scan testing can be performed either before or after, but not during configuration. Stratix II devices can also use the JTAG port for configuration with the Quartus(R) II software or hardware using either Jam Files (.jam) or Jam Byte-Code Files (.jbc). Stratix II devices support IOE I/O standard setting reconfiguration through the JTAG BST chain. The JTAG chain can update the I/O standard for all input and output pins any time before or during user mode through the CONFIG_IO instruction. Designers can use this capability for JTAG testing before configuration when some of the Stratix II pins drive or receive from other devices on the board using voltage-referenced standards. Since the Stratix II device may not be configured before JTAG testing, the I/O pins may not be configured for appropriate electrical standards for chip-to-chip communication. Programming those I/O standards via JTAG allows designers to fully test I/O connections to other devices. A device operating in JTAG mode uses four required pins, TDI,TDO, TMS, and TCK, and one optional pin, TRST. The TCK pin has an internal weak pull-down resistor, while the TDI,TMS and TRST pins have weak internal pull-ups. The JTAG input pins are powered by the 3.3-V VCCPD pins. The TDO output pin is powered by the VCCIO power supply of bank 4. Stratix II devices also use the JTAG port to monitor the logic operation of the device with the SignalTap(R) II embedded logic analyzer. Stratix II devices support the JTAG instructions shown in Table 3-1. 1 Stratix II, Stratix, Cyclone II, and Cyclone devices must be within the first 17 devices in a JTAG chain. All of these devices have the same JTAG controller. If any of the Stratix II, Stratix, Cyclone II, or Cyclone devices are in the 18th of further position, they will fail configuration. This does not affect SignalTap II.
Altera Corporation January 2005
3-1
IEEE Std. 1149.1 JTAG Boundary-Scan Support
Table 3-1. Stratix II JTAG Instructions JTAG Instruction
SAMPLE/PRELOAD
Instruction Code
00 0000 0101
Description
Allows a snapshot of signals at the device pins to be captured and examined during normal device operation, and permits an initial data pattern to be output at the device pins. Also used by the SignalTap II embedded logic analyzer. Allows the external circuitry and board-level interconnects to be tested by forcing a test pattern at the output pins and capturing test results at the input pins. Places the 1-bit bypass register between the TDI and TDO pins, which allows the BST data to pass synchronously through selected devices to adjacent devices during normal device operation. Selects the 32-bit USERCODE register and places it between the TDI and TDO pins, allowing the USERCODE to be serially shifted out of TDO. Selects the IDCODE register and places it between TDI and TDO, allowing the IDCODE to be serially shifted out of TDO. Places the 1-bit bypass register between the TDI and TDO pins, which allows the BST data to pass synchronously through selected devices to adjacent devices during normal device operation, while tri-stating all of the I/O pins. Places the 1-bit bypass register between the TDI and TDO pins, which allows the BST data to pass synchronously through selected devices to adjacent devices during normal device operation while holding I/O pins to a state defined by the data in the boundary-scan register. Used when configuring a Stratix II device via the JTAG port with a USB Blaster, MasterBlasterTM, ByteBlasterMVTM, or ByteBlaster II download cable, or when using a .jam or .jbc via an embedded processor or JRunner.
EXTEST(1)
00 0000 1111
BYPASS
11 1111 1111
USERCODE
00 0000 0111
IDCODE HIGHZ (1)
00 0000 0110 00 0000 1011
CLAMP (1)
00 0000 1010
ICR instructions
PULSE_NCONFIG CONFIG_IO (2)
00 0000 0001 00 0000 1101
Emulates pulsing the nCONFIG pin low to trigger reconfiguration even though the physical pin is unaffected. Allows configuration of I/O standards through the JTAG chain for JTAG testing. Can be executed before, during, or after configuration. Stops configuration if executed during configuration. Once issued, the CONFIG_IO instruction will hold nSTATUS low to reset the configuration device. nSTATUS is held low until the IOE configuration register is loaded and the TAP controller state machine transitions to the UPDATE_DR state. Monitors internal device operation with the SignalTap II embedded logic analyzer.
SignalTap II instructions Note to Table 3-1:
(1) (2)
Bus hold and weak pull-up resistor features override the high-impedance state of HIGHZ, CLAMP, and EXTEST. For more information on using the CONFIG_IO instruction, see the MorphIO: An I/O Reconfiguration Solution for Altera Devices White Paper.
3-2 Stratix II Device Handbook, Volume 1
Altera Corporation January 2005
Configuration & Testing
The Stratix II device instruction register length is 10 bits and the USERCODE register length is 32 bits. Tables 3-2 and 3-3 show the boundary-scan register length and device IDCODE information for Stratix II devices.
Table 3-2. Stratix II Boundary-Scan Register Length Device
EP2S15 EP2S30 EP2S60 EP2S90 EP2S130 EP2S180
Boundary-Scan Register Length
1,140 1,692 2,196 2,748 3,420 3,948
Table 3-3. 32-Bit Stratix II Device IDCODE IDCODE (32 Bits) (1) Device
EP2S15 EP2S30 EP2S60 EP2S90 EP2S130 EP2S180 Notes to Table 3-3:
(1) (2) The most significant bit (MSB) is on the left. The IDCODE's least significant bit (LSB) is always 1.
Version (4 Bits)
0000 0000 0001 0000 0000 0000
Part Number (16 Bits)
0010 0000 1001 0001 0010 0000 1001 0010 0010 0000 1001 0011 0010 0000 1001 0100 0010 0000 1001 0101 0010 0000 1001 0110
Manufacturer Identity (11 LSB (1 Bit) (2) Bits)
000 0110 1110 000 0110 1110 000 0110 1110 000 0110 1110 000 0110 1110 000 0110 1110 1 1 1 1 1 1
1
Stratix, Stratix II, Cyclone, and Cyclone II devices must be within the first 17 devices in a JTAG chain. All of these devices have the same JTAG controller. If any of the Stratix, Stratix II, Cyclone, and Cyclone II devices are in the 18th or after they will fail configuration. This does not affect SignalTap II.
f
For more information on JTAG, see the following documents:

Chapter 9, IEEE Std. 1149.1 (JTAG) Boundary-Scan Testing in Stratix II Devices in the Stratix II Device Handbook, Volume 2 Jam Programming & Test Language Specification
Altera Corporation January 2005
3-3 Stratix II Device Handbook, Volume 1
SignalTap II Embedded Logic Analyzer
SignalTap II Embedded Logic Analyzer
Stratix II devices feature the SignalTap II embedded logic analyzer, which monitors design operation over a period of time through the IEEE Std. 1149.1 (JTAG) circuitry. A designer can analyze internal logic at speed without bringing internal signals to the I/O pins. This feature is particularly important for advanced packages, such as FineLine BGA packages, because it can be difficult to add a connection to a pin during the debugging process after a board is designed and manufactured. The logic, circuitry, and interconnects in the Stratix II architecture are configured with CMOS SRAM elements. Altera FPGA devices are reconfigurable and every device is tested with a high coverage production test program so the designer does not have to perform fault testing and can instead focus on simulation and design verification. Stratix II devices are configured at system power-up with data stored in an Altera configuration device or provided by an external controller (e.g., a MAX(R) II device or microprocessor). Stratix II devices can be configured using the fast passive parallel (FPP), active serial (AS), passive serial (PS), passive parallel asynchronous (PPA), and JTAG configuration schemes. The Stratix II device's optimized interface allows microprocessors to configure it serially or in parallel, and synchronously or asynchronously. The interface also enables microprocessors to treat Stratix II devices as memory and configure them by writing to a virtual memory location, making reconfiguration easy. In addition to the number of configuration methods supported, Stratix II devices also offer the design security, decompression, and remote system upgrade features. The design security feature, using configuration bitstream encryption and AES technology, provides a mechanism to protect your designs. The decompression feature allows Stratix II FPGAs to receive a compressed configuration bitstream and decompress this data in real-time, reducing storage requirements and configuration time. The remote system upgrade feature allows real-time system upgrades from remote locations of your Stratix II designs. For more information, see the "Configuration Schemes" section.
Configuration
Operating Modes
The Stratix II architecture uses SRAM configuration elements that require configuration data to be loaded each time the circuit powers up. The process of physically loading the SRAM data into the device is called configuration. During initialization, which occurs immediately after configuration, the device resets registers, enables I/O pins, and begins to operate as a logic device. The I/O pins are tri-stated during power-up,
3-4 Stratix II Device Handbook, Volume 1
Altera Corporation January 2005
Configuration & Testing
and before and during configuration. Together, the configuration and initialization processes are called command mode. Normal device operation is called user mode. SRAM configuration elements allow Stratix II devices to be reconfigured in-circuit by loading new configuration data into the device. With realtime reconfiguration, the device is forced into command mode with a device pin. The configuration process loads different configuration data, reinitializes the device, and resumes user-mode operation. Designers can perform in-field upgrades by distributing new configuration files either within the system or remotely. PORSEL is a dedicated input pin used to select POR delay times of 12 ms or 100 ms during power-up. When the PORSEL pin is connected to ground, the POR time is 100 ms; when the PORSEL pin is connected to VCC, the POR time is 12 ms. The nIO PULLUP pin is a dedicated input that chooses whether the internal pull-ups on the user I/O pins and dual-purpose configuration I/O pins (nCSO, ASDO, DATA[7..0], nWS, nRS, RDYnBSY, nCS, CS, RUnLU, PGM[2..0], CLKUSR, INIT_DONE, DEV_OE, DEV_CLR) are on or off before and during configuration. A logic high (1.5, 1.8, 2.5, 3.3 V) turns off the weak internal pull-ups, while a logic low turns them on. Stratix II devices also offer a new power supply, VCCPD, which must be connected to 3.3 V in order to power the 3.3-V/2.5-V buffer available on the configuration input pins and JTAG pins. VCCPD applies to all the JTAG input pins (TCK, TMS, TDI, and TRST) and the following configuration pins: nCONFIG, DCLK (when used as an input), nIO_PULLUP, DATA[7..0], RUnLU, nCE, nWS, nRS, CS, nCS, and CLKUSR. The VCCSEL pin allows the VCCIO setting (of the banks where the configuration inputs reside) to be independent of the voltage required by the configuration inputs. Therefore, when selecting the VCCIO, the VIL and VIH levels driven to the configuration inputs do not have to be a concern. The configuration input pins (nCONFIG, DCLK (when used as an input), nIO_PULLUP, RUnLU, nCE, nWS, nRS, CS, nCS, and CLKUSR) have a dual buffer design: a 3.3-V/2.5-V input buffer and a 1.8-V/1.5-V input buffer. The VCCSEL input pin selects which input buffer is used. The 3.3-V/2.5-V input buffer is powered by VCCPD, while the 1.8-V/1.5-V input buffer is powered by VCCIO. VCCSEL is sampled during power-up. Therefore, the VCCSEL setting cannot change on the fly or during a reconfiguration. The VCCSEL input buffer is powered by VCCINT and must be hardwired to VCCPD or ground. A logic high VCCSEL connection selects the 1.8-V/1.5-V input buffer, and
Altera Corporation January 2005
3-5 Stratix II Device Handbook, Volume 1
Configuration
a logic low selects the 3.3-V/2.5-V input buffer. VCCSEL should be set to comply with the logic levels driven out of the configuration device or MAX(R) II/microprocessor. If you need to support configuration input voltages of 3.3 V/2.5 V, you should set the VCCSEL to a logic low; you can set the VCCIO of the I/O bank that contains the configuration inputs to any supported voltage. If you need to support configuration input voltages of 1.8 V/1.5 V, you should set the VCCSEL to a logic high and the VCCIO of the bank that contains the configuration inputs to 1.8 V/1.5 V.
f
For more information on multi-volt support, including information on using TDO and nCEO in multi-volt systems, refer to the "MultiVolt I/O Interface" section in the Stratix II Architecture chapter in Volume 1 of the Stratix II Handbook.
Configuration Schemes
Designers can load the configuration data for a Stratix II device with one of five configuration schemes (see Table 3-4), chosen on the basis of the target application. Designers can use a configuration device, intelligent controller, or the JTAG port to configure a Stratix II device. A configuration device can automatically configure a Stratix II device at system power-up. Multiple Stratix II devices can be configured in any of the five configuration schemes by connecting the configuration enable (nCE) and configuration enable output (nCEO) pins on each device. Stratix II FPGAs offer the following:

Configuration data decompression to reduce configuration file storage Design security using configuration data encryption to protect your designs Remote system upgrades for remotely updating your Stratix II designs
Table 3-4 summarizes which configuration features can be used in each configuration scheme. See the Configuring Stratix II Devices chapter in the Stratix II Device Handbook, Volume 2 for more information about configuration schemes in Stratix II devices.
3-6 Stratix II Device Handbook, Volume 1
Altera Corporation January 2005
Configuration & Testing
Table 3-4. Stratix II Configuration Features Configuration Scheme
FPP
Configuration Method
MAX II device or microprocessor and flash device Enhanced configuration device
Design Security Decompression v (1) v (1) v (2) v v v v v v v v
Remote System Upgrade v v v (3) v v v
AS PS
Serial configuration device MAX II device or microprocessor and flash device Enhanced configuration device Download cable (4)
PPA JTAG
MAX II device or microprocessor and flash device Download cable (4) MAX II device or microprocessor and flash device
Notes for Table 3-4:
(1) (2) (3) (4) In these modes, the host system must send a DCLK that is 4x the data rate. The enhanced configuration device decompression feature is available, while the Stratix II decompression feature is not available. Only remote update mode is supported when using the AS configuration scheme. Local update mode is not supported. The supported download cables include the Altera USB Blaster universal serial bus (USB) port download cable, MasterBlaster serial/USB communications cable, ByteBlaster II parallel port download cable, and the ByteBlasterMV parallel port download cable.
Device Security Using Configuration Bitstream Encryption
Stratix II FPGAs are the industry's first FPGAs with the ability to decrypt a configuration bitstream using the Advanced Encryption Standard (AES) algorithm. When using the design security feature, a 128-bit security key is stored in the Stratix II FPGA. To successfully configure a Stratix II FPGA that has the design security feature enabled, it must be configured with a configuration file that was encrypted using the same 128-bit security key. The security key can be stored in non-volatile memory inside the Stratix II device. This non-volatile memory does not require any external devices, such as a battery back-up, for storage.
Altera Corporation January 2005
3-7 Stratix II Device Handbook, Volume 1
Configuration
1
An encryption configuration file is the same size as a nonencryption configuration file. When using a serial configuration scheme such as passive serial (PS) or active serial (AS), configuration time is the same whether or not the design security feature is enabled. If the fast passive parallel (FPP) scheme us used with the design security or decompression feature, a 4x DCLK is required. This results in a slower configuration time when compared to the configuration time of an FPGA that has neither the design security, nor decompression feature enabled. For more information about this feature, contact your local Altera sales representative.
Device Configuration Data Decompression
Stratix II FPGAs support decompression of configuration data, which saves configuration memory space and time. This feature allows you to store compressed configuration data in configuration devices or other memory, and transmit this compressed bit stream to Stratix II FPGAs. During configuration, the Stratix II FPGA decompresses the bit stream in real time and programs its SRAM cells. Stratix II FPGAs support decompression in the FPP (when using a MAX II device/microprocessor and flash memory), AS and PS configuration schemes. Decompression is not supported in the PPA configuration scheme nor in JTAG-based configuration.
Remote System Upgrades
Shortened design cycles, evolving standards, and system deployments in remote locations are difficult challenges faced by modern system designers. Stratix II devices can help effectively deal with these challenges with their inherent re-programmability and dedicated circuitry to perform remote system updates. Remote system updates help deliver feature enhancements and bug fixes without costly recalls, reduce time to market, and extend product life. Stratix II FPGAs feature dedicated remote system upgrade circuitry to facilitate remote system updates. Soft logic (Nios processor or user logic) implemented in the Stratix II device can download a new configuration image from a remote location, store it in configuration memory, and direct the dedicated remote system upgrade circuitry to initiate a reconfiguration cycle. The dedicated circuitry performs error detection during and after the configuration process, recovers from any error condition by reverting back to a safe configuration image, and provides error status information. This dedicated remote system upgrade circuitry avoids system downtime and is the critical component for successful remote system upgrades.
3-8 Stratix II Device Handbook, Volume 1
Altera Corporation January 2005
Configuration & Testing
RSC is supported in the following Stratix II configuration schemes: FPP, AS, PS, and PPA. RSC can also be implemented in conjunction with advanced Stratix II features such as real-time decompression of configuration data and design security using AES for secure and efficient field upgrades. See the Remote System Upgrades with Stratix II Devices chapter in the Stratix II Device Handbook, Volume 2 for more information about remote configuration in Stratix II devices.
Configuring Stratix II FPGAs with JRunner
JRunner is a software driver that configures Altera FPGAs, including Stratix II FPGAs, through the ByteBlaster II or ByteBlasterMV cables in JTAG mode. The programming input file supported is in Raw Binary File (.rbf) format. JRunner also requires a Chain Description File (.cdf) generated by the Quartus II software. JRunner is targeted for embedded JTAG configuration. The source code is developed for the Windows NT operating system (OS), but can be customized to run on other platforms. For more information on the JRunner software driver, see the JRunner Software Driver: An Embedded Solution to the JTAG Configuration White Paper and the source files on the Altera web site (www.altera.com).
Programming Serial Configuration Devices with SRunner
A serial configuration device can be programmed in-system by an external microprocessor using SRunner. SRunner is a software driver developed for embedded serial configuration device programming that can be easily customized to fit in different embedded systems. SRunner is able to read a .rpd file (Raw Programming Data) and write to the serial configuration devices. The serial configuration device programming time using SRunner is comparable to the programming time when using the Quartus II software. For more information about SRunner, see the SRunner: An Embedded Solution for EPCS Programming White Paper and the source code on the Altera web site at www.altera.com. For more information on programming serial configuration devices, see the Serial Configuration Devices (EPCS1 & EPCS4) Data Sheet in the Configuration Handbook.
Altera Corporation January 2005
3-9 Stratix II Device Handbook, Volume 1
Temperature Sensing Diode
Configuring Stratix II FPGAs with the MicroBlaster Driver
The MicroBlasterTM software driver supports an RBF programming input file and is ideal for embedded FPP or PS configuration. The source code is developed for the Windows NT operating system, although it can be customized to run on other operating systems. For more information on the MicroBlaster software driver, see the Configuring the MicroBlaster Fast Passive Parallel Software Driver White Paper or the Configuring the MicroBlaster Passive Serial Software Driver White Paper on the Altera web site (www.altera.com).
PLL Reconfiguration
The phase-locked loops (PLLs) in the Stratix II device family support reconfiguration of their multiply, divide, VCO-phase selection, and bandwidth selection settings without reconfiguring the entire device. Designers can use either serial data from the logic array or regular I/O pins to program the PLL's counter settings in a serial chain. This option provides considerable flexibility for frequency synthesis, allowing realtime variation of the PLL frequency and delay. The rest of the device is functional while reconfiguring the PLL. See the Stratix II PLLs and Clocking Structures chapter in the Stratix II Device Handbook, Volume 2 for more information on Stratix II PLLs.
Temperature Sensing Diode
Stratix II devices include a diode-connected transistor for use as a temperature sensor in power management. This diode is used with an external digital thermometer device such as a MAX1617A or MAX1619 from MAXIM Integrated Products. These devices steer bias current through the Stratix II diode, measuring forward voltage and converting this reading to temperature in the form of an 8-bit signed number (7 bits plus sign). The external device's output represents the junction temperature of the Stratix II device and can be used for intelligent power management. The diode requires two pins (tempdiodep and tempdioden) on the Stratix II device to connect to the external temperature-sensing device, as shown in Figure 3-1. The temperature sensing diode is a passive element and therefore can be used before the Stratix II device is powered.
3-10 Stratix II Device Handbook, Volume 1
Altera Corporation January 2005
Configuration & Testing
Figure 3-1. External Temperature-Sensing Diode
Stratix II Device Temperature-Sensing Device
tempdiodep
tempdioden
Table 3-5 shows the specifications for bias voltage and current of the Stratix II temperature sensing diode.
Table 3-5. Temperature-Sensing Diode Electrical Characteristics Parameter
IBIAS high IBIAS low VBP - VBN VBN Series resistance
Minimum
80 8 0.3
Typical
100 10
Maximum
120 12 0.9
Unit
A A V V
0.7 3
The temperature-sensing diode works for the entire operating range shown in Figure 3-2.
Altera Corporation January 2005
3-11 Stratix II Device Handbook, Volume 1
Automated Single Event Upset (SEU) Detection
Figure 3-2. Temperature vs. Temperature-Sensing Diode Voltage
0.95 0.90 0.85 0.80 0.75 Voltage (Across Diode) 0.70 0.65 0.60 0.55 0.50 0.45 0.40 -55 -30 -5 20 45 70 95 120 100 A Bias Current 10 A Bias Current
Temperature (C)
Automated Single Event Upset (SEU) Detection
Stratix II devices offer on-chip circuitry for automated checking of single event upset (SEU) detection. Some applications that require the device to operate error free at high elevations or in close proximity to Earth's North or South Pole will require periodic checks to ensure continued data integrity. The error detection cyclic redundancy check (CRC) feature controlled by the Device & Pin Options dialog box in the Quartus II software uses a 32-bit CRC circuit to ensure data reliability and is one of the best options for mitigating SEU. Designers can implement the error detection CRC feature with existing circuitry in Stratix II devices, eliminating the need for external logic. For Stratix II, CRC is computed by the device during configuration and checked against an automatically computed CRC during normal operation. The CRC_ERROR pin reports a soft error when configuration SRAM data is corrupted, triggering device reconfiguration.
3-12 Stratix II Device Handbook, Volume 1
Altera Corporation January 2005
Configuration & Testing
Custom-Built Circuitry
Dedicated circuitry is built in the Stratix II devices to perform error detection automatically. This error detection circuitry in Stratix II devices constantly checks for errors in the configuration SRAM cells while the device is in user mode. Designers can monitor one external pin for the error and use it to trigger a re-configuration cycle. The designer can select the desired time between checks by adjusting a built-in clock divider.
Software Interface
In the Quartus II software version 4.1 and later, designers can turn on the automated error detection CRC feature in the Device & Pin Options dialog box. This dialog box allows you to enable the feature and set the internal frequency of the CRC between 400 kHz to 100 MHz. This controls the rate that the CRC circuitry verifies the internal configuration SRAM bits in the FPGA device. For more information on CRC, refer to AN 357: Error Detection Using CRC in Altera FPGA Devices.
Altera Corporation January 2005
3-13 Stratix II Device Handbook, Volume 1
Automated Single Event Upset (SEU) Detection
3-14 Stratix II Device Handbook, Volume 1
Altera Corporation January 2005
4. Hot Socketing, ESD & Power-On Reset
SII51004-2.1
Stratix(R) II devices offer hot socketing, which is also known as hot plug-in or hot swap, and power sequencing support without the use of any external devices. Designers can insert or remove a Stratix II board in a system during system operation without causing undesirable effects to the running system bus or the board that was inserted into the system. The hot socketing feature also removes some of the difficulty when designers use Stratix II devices on printed circuit boards (PCBs) that also contain a mixture of 5.0-, 3.3-, 2.5-, 1.8-, 1.5- and 1.2-V devices. With the Stratix II hot socketing feature, designers no longer need to ensure a proper power-up sequence for each device on the board. The Stratix II hot socketing feature provides:

Board or device insertion and removal without external components or board manipulation Support for any power-up sequence Non-intrusive I/O buffers to system buses during hot insertion
This chapter also discusses the electro-static discharge (ESD) protection and the power-on reset (POR) circuitry in Stratix II devices. The POR circuitry keeps the devices in the reset state until the VCC is within operating range.
Stratix II HotSocketing Specifications
Stratix II devices offer hot socketing capability with all three features listed above without any external components or special design requirements. The hot socketing feature in Stratix II devices allows:

The device can be driven before power-up without any damage to the device itself. I/O pins remain tri-stated during power-up. The device does not drive out before or during power-up, thereby affecting other buses in operation. Signal pins do not drive the VCCIO, VCCPD, or VCCINT power supplies. External input signals to I/O pins of the device do not internally power the VCCIO or VCCINT power supplies of the device via internal paths within the device.
Altera Corporation January 2005
4-1
Stratix II Hot-Socketing Specifications
Devices Can Be Driven before Power-Up
You can drive signals into the I/O pins, dedicated input pins and dedicated clock pins of Stratix II devices before or during power-up or power-down without damaging the device. Stratix II devices support any power-up or power-down sequence (VCCIO, VCCINT, and VCCPD) in order to simplify system level design.
I/O Pins Remain Tri-Stated during Power-Up
A device that does not support hot-socketing may interrupt system operation or cause contention by driving out before or during power-up. In a hot socketing situation, Stratix II device's output buffers are turned off during system power-up or power-down. Stratix II device also does not drive out until the device is configured and has attained proper operating conditions.
Signal Pins Do Not Drive the VCCIO, VCCINT or VCCPD Power Supplies
Devices that do not support hot-socketing can short power supplies together when powered-up through the device signal pins. This irregular power-up can damage both the driving and driven devices and can disrupt card power-up. Stratix II devices do not have a current path from I/O pins, dedicated input pins, or dedicated clock pins to the VCCIO, VCCINT, or VCCPD pins before or during power-up. A Stratix II device may be inserted into (or removed from) a powered-up system board without damaging or interfering with system-board operation. When hot-socketing, Stratix II devices may have a minimal effect on the signal integrity of the backplane. 1 You can power up or power down the VCCIO, VCCINT, and VCCPD pins in any sequence. The power supply ramp rates can range from 100 s to 100 ms. All VCC supplies must power down within 100 ms of each other. During hot socketing, the I/O pin capacitance is less than 15 pF and the clock pin capacitance is less than 20 pF. Stratix II devices meet the following hot socketing specification. The hot socketing DC specification is: | IIOPIN | < 300 A The hot socketing AC specification is: | IIOPIN | < 8 mA or | IIOPIN | > 8 mA for 10 ns or less

4-2 Stratix II Device Handbook, Volume 1
Altera Corporation January 2005
Hot Socketing, ESD & Power-On Reset
IIOPIN is the current at any user I/O pin on the device. The AC specification has two requirements. The peak current during power-up or power-down is < 8 mA. The peak current is allowed to exceed 8 mA for 10 ns or less. A possible concern regarding hot-socketing is the potential for latch-up. Latch-up can occur when electrical subsystems are hot-socketed into an active system. During hot-socketing, the signal pins may be connected and driven by the active system before the power supply can provide current to the device's VCC and ground planes. This condition can lead to latch-up and cause a low-impedance path from VCC to ground within the device. As a result, the device extends a large amount of current, possibly causing electrical damage. Nevertheless, Stratix II devices are immune to latch-up when hot-socketing.
Hot Socketing Feature Implementation in Stratix II Devices
The hot socketing feature turns off the output buffer during the power-up event (either VCCINT, VCCIO, or VCCPD supplies) or power down. The hotsocket circuit will generate an internal HOTSCKT signal when either VCCINT, VCCIO, or VCCPD is below threshold voltage. The HOTSCKT signal will cut off the output buffer to make sure that no DC current (except for weak pull up leaking) leaks through the pin. When VCC ramps up very slowly, VCC is still relatively low even after the POR signal is released and the configuration is finished. The CONF_DONE, nCEO, and nSTATUS pins fail to respond, as the output buffer can not flip from the state set by the hot socketing circuit at this low VCC voltage. Therefore, the hot socketing circuit has been removed on these configuration pins to make sure that they are able to operate during configuration. It is expected behavior for these pins to drive out during power-up and power-down sequences. Each I/O pin has the following circuitry shown in Figure 4-1.
Altera Corporation January 2005
4-3 Stratix II Device Handbook, Volume 1
Hot Socketing Feature Implementation in Stratix II Devices
Figure 4-1. Hot Socketing Circuit Block Diagram for Stratix II Devices
Power On Reset Monitor
Output
Weak Pull-Up Resistor
PAD
R Output Enable
Voltage Tolerance Control
Hot Socket
Output Pre-Driver
Input Buffer to Logic Array
The POR circuit monitors VCCINT voltage level and keeps I/O pins tristated until the device is in user mode. The weak pull-up resistor (R) from the I/O pin to VCCIO is present to keep the I/O pins from floating. The 3.3-V tolerance control circuit permits the I/O pins to be driven by 3.3 V before VCCIO and/or VCCINT and/or VCCPD are powered, and it prevents the I/O pins from driving out when the device is not in user mode. The hot socket circuit prevents I/O pins from internally powering VCCIO, VCCINT, and VCCPD when driven by external signals before the device is powered. Figure 4-2 shows a transistor level cross section of the Stratix II device I/O buffers. This design ensures that the output buffers do not drive when VCCIO is powered before VCCINT or if the I/O pad voltage is higher than VCCIO. This also applies for sudden voltage spikes during hot insertion. There is no current path from signal I/O pins to VCCINT or VCCIO or VCCPD during hot insertion. The VPAD leakage current charges the 3.3-V tolerant circuit capacitance.
4-4 Stratix II Device Handbook, Volume 1
Altera Corporation January 2005
Hot Socketing, ESD & Power-On Reset
Figure 4-2. Transistor Level Diagram of FPGA Device I/O Buffers
Logic Array Signal VPAD
(1)
VCCIO
(2)
n+ p-well
n+
p+
p+ n-well
n+
p-substrate
Notes to Figure 4-2:
(1) (2) This is the logic array signal or the larger of either the VCCIO or VPAD signal. This is the larger of either the VCCIO or VPAD signal.
ESD Protection
The CMOS output drivers in the I/O pins intrinsically provide ESD protection. ESD voltage strikes can cause a positive voltage zap or a negative voltage zap. A positive ESD voltage zap occurs when a positive voltage is present on an I/O pin due to an ESD charge event. This can cause the N+ (Drain)/PSubstrate junction of the N-channel drain to break down and the N+ (Drain)/P-Substrate/N+ (Source) intrinsic bipolar transistor turns on to discharge ESD current from I/O pin to GND. The arrows in Figure 4-3 show the ESD current discharge path during a positive ESD zap.
Altera Corporation January 2005
4-5 Stratix II Device Handbook, Volume 1
ESD Protection
Figure 4-3. ESD Protection During Positive Voltage Zap
Source Gate Drain I/O Pin Drain Gate Source
P-Substrate I/O Pin D N+
Ground
N+
S
Ground
Ground
Ground
When the I/O pin receives a negative ESD zap at the pin that is less than -0.7 V (0.7 V is the voltage drop across a diode), the intrinsic PSubstrate/N+ drain diode is forward biased. Hence, the discharge ESD current path is from GND to the I/O pin as shown in Figure 4-4.
4-6 Stratix II Device Handbook, Volume 1
Altera Corporation January 2005
Hot Socketing, ESD & Power-On Reset
Figure 4-4. ESD Protection During Negative Voltage Zap
Source Gate Drain I/O Pin Drain Gate Source
P-Substrate I/O Pin D N+
Ground
N+
S
Ground
Ground
Ground
f
For the maximum specification of ESD protection, see the DC & Switching Characteristics chapter in Volume 1 of the Stratix II Device Handbook. The maximum specification of ESD protection will be published in a future version of the Reliability Report, available on the Altera web site at www.altera.com.
Power-On Reset Circuitry
Stratix II devices have a POR circuit to keep the whole device system in reset state until the power supply voltage levels have stabilized during power-up. The POR circuit monitors the VCCINT, VCCIO, and VCCPD voltage levels and tri-states all the user I/O pins while VCC is ramping up until normal user levels are reached. The POR circuitry also ensures that all eight I/O bank VCCIO voltages, VCCPD voltage, as well as the logic array VCCINT voltage, reach an acceptable level before configuration is triggered. After the Stratix II device enters user mode, the POR circuit continues to monitor the VCCINT voltage level so that a brown-out condition during user mode can be detected. If there is a VCCINT voltage sag below the Stratix II operational level during user mode, the POR circuit resets the device.
Altera Corporation January 2005
4-7 Stratix II Device Handbook, Volume 1
Power-On Reset Circuitry
When power is applied to a Stratix II device, a power-on-reset event occurs if VCC reaches the recommended operating range within a certain period of time (specified as a maximum VCC rise time). The maximum VCC rise time for Stratix II device is 100 ms. Stratix II devices provide a dedicated input pin (PORSEL) to select POR delay times of 12 or 100 ms during power-up. When the PORSEL pin is connected to ground, the POR time is 100 ms. When the PORSEL pin is connected to VCC, the POR time is 12 ms.
4-8 Stratix II Device Handbook, Volume 1
Altera Corporation January 2005
5. DC & Switching Characteristics
SII51005-2.2
Operating Conditions
Stratix(R) II devices are offered in both commercial and industrial grades. Industrial devices are offered in -4 and -5 speed grades and commercial devices are offered in -3 (fastest), -4, -5 speed grades. Tables 5-1 through 5-30 provide information on absolute maximum ratings, recommended operating conditions, DC electrical characteristics, and other specifications for Stratix II devices.
Absolute Maximum Ratings
Table 5-1 contains the absolute maximum ratings for the Stratix II device family.
Table 5-1. Stratix II Device Absolute Maximum Ratings Symbol
VCCINT VCCIO VCCPD VI IOUT TSTG TJ
(1) (2) (3) (4)
Notes (1), (2), (3) Minimum
-0.5 -0.5 3.0 -0.5 -25
Parameter
Supply voltage Supply voltage Supply voltage DC input voltage (4) DC output current, per pin Storage temperature Junction temperature No bias
Conditions
With respect to ground With respect to ground With respect to ground
Maximum
1.8 4.6 3.6 4.6 40 150 125
Unit
V V V V mA C C
-65 -55
BGA packages under bias
Notes to Tables 5-1
See the Operating Requirements for Altera Devices Data Sheet. Conditions beyond those listed in Table 5-1 may cause permanent damage to a device. Additionally, device operation at the absolute maximum ratings for extended periods of time may have adverse affects on the device. Supply voltage specifications apply to voltage readings taken at the device pins, not at the power supply. During transitions, the inputs may overshoot to the voltage shown in Table 5-2 based upon the input duty cycle. The DC case is equivalent to 100% duty cycle. During transitions, the inputs may undershoot to -2.0 V for input currents less than 100 mA and periods shorter than 20 ns.
Altera Corporation March 2005
5-1
Operating Conditions
Table 5-2. Maximum Duty Cycles in Voltage Transitions VI N (Volts)
4.0 4.1 4.2 4.3 4.4 4.5
Maximum Duty Cycles
100% 90% 50% 30% 17% 10%
Recommended Operating Conditions
Table 5-3 contains the Stratix II device family recommended operating conditions.
Table 5-3. Stratix II Device Recommended Operating Conditions (Part 1 of 2) Symbol
VCCINT VCCIO
Note (1) Maximum Unit
1.25 3.60 2.625 1.89 1.575 3.465 V V V V V V
Parameter
Supply voltage for internal logic and input buffers
Conditions
Maximum risetime = 100 ms (3)
Minimum
1.15 3.00 2.375 1.71 1.425 3.135
Supply voltage for output buffers, Maximum risetime = 100 ms (3) 3.3-V operation Supply voltage for output buffers, Maximum risetime = 100 ms (3) 2.5-V operation Supply voltage for output buffers, Maximum risetime = 100 ms (3) 1.8-V operation Supply voltage for output buffers, Maximum risetime = 100 ms (3) 1.5-V operation
VCCPD
Supply voltage for pre-drivers as well as configuration and JTAG I/O buffers. Input voltage Output voltage
100 s risetime 100 ms (4)
VI VO
(2), (5)
-0.5 0
4.0 VCCIO
V V
5-2 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-3. Stratix II Device Recommended Operating Conditions (Part 2 of 2) Symbol
TJ
Note (1) Maximum Unit
85 100 C C
Parameter
Operating junction temperature
Conditions
For commercial use For industrial use
Minimum
0 -40
Notes to Table 5-3:
(1) (2) Supply voltage specifications apply to voltage readings taken at the device pins, not at the power supply. During transitions, the inputs may overshoot to the voltage shown in Table 5-2 based upon the input duty cycle. The DC case is equivalent to 100% duty cycle. During transitions, the inputs may undershoot to -2.0 V for input currents less than 100 mA and periods shorter than 20 ns. Maximum VCC rise time is 100 ms, and VCC must rise monotonically. VCCPD must ramp-up from 0 V to 3.3 V within 100 s to 100 ms. If VCCPD is not ramped up within this specified time, your Stratix II device will not configure successfully. If your system does not allow for a VCCPD ramp-up time of 100 ms or less, you must hold nCONFIG low until all power supplies are reliable. All pins, including dedicated inputs, clock, I/O, and JTAG pins, may be driven before VCCINT, VCCPD, and VCCIO are powered.
(3) (4)
(5)
DC Electrical Characteristics
Table 5-4 shows the Stratix II device family DC electrical characteristics.
Table 5-4. Stratix II Device DC Operating Conditions Symbol
II IOZ ICC0
Note (1) Minimum
-10 -10 (3)
Parameter
Input pin leakage current
Conditions
VI = VCCIOmax to 0 V (2)
Typical
Maximum Unit
10 10 A A mA
Tri-stated I/O pin leakage current VO = VCCIOmax to 0 V (2) VCC supply current (standby) (all memory blocks in power-down mode) Value of I/O pin pull-up resistor before and during configuration VI = ground, no load, no toggling inputs VCCIO = 3.0 V (4) VCCIO = 2.375 V (4) VCCIO = 1.71 V (4)
RCONF
20 30 60
50 80 150
k k k
Notes to Table 5-4:
(1) (2) (3) (4) Typical values are for TA = 25C, VCCINT = 1.2 V, and VCCIO = 1.5 V, 1.8 V, 2.5 V, and 3.3 V. This value is specified for normal device operation. The value may vary during power-up. This applies for all VCCIO settings (3.3, 2.5, 1.8, and 1.5 V). This specification is pending device characterization. Pin pull-up resistance values will lower if an external source drives the pin higher than VCCIO.
Altera Corporation March 2005
5-3 Stratix II Device Handbook, Volume 1
Operating Conditions
I/O Standard Specifications
Tables 5-5 through 5-30 show the Stratix II device family I/O standard specifications.
Table 5-5. LVTTL Specifications Symbol
VCCIO (1) VI H VIL VOH VOL
(1) (2)
Parameter
Output supply voltage High-level input voltage Low-level input voltage High-level output voltage Low-level output voltage
Conditions
Minimum
3.135 1.7 -0.3
Maximum
3.465 4.0 0.8
Unit
V V V V
IOH = -4 mA (2) IOL = 4 mA (2)
2.4 0.45
V
Notes to Tables 5-5:
Stratix II devices comply to the narrow range for the supply voltage as specified in the EIA/JEDEC Standard, JESD8-B. This specification is supported across all the programmable drive strength settings available for this I/O standard as shown in Table 2-17 on page 2-85.
Table 5-6. LVCMOS Specifications Symbol
VCCIO (1) VIH VIL VOH VOL
Parameter
Output supply voltage High-level input voltage Low-level input voltage High-level output voltage Low-level output voltage
Conditions
Minimum
3.135 1.7 -0.3
Maximum
3.465 4.0 0.8
Unit
V V V V
VCCIO = 3.0, IOH = -0.1 mA (2) VCCIO = 3.0, IOL = 0.1 mA (2)
VCCIO - 0.2 0.2
V
Notes to Table 5-6:
(1) (2) Stratix II devices comply to the narrow range for the supply voltage as specified in the EIA/JEDEC Standard, JESD8-B. This specification is supported across all the programmable drive strength available for this I/O standard as shown in Table 2-17 on page 2-85.
5-4 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-7. 2.5-V I/O Specifications Symbol
VCCIO (1) VIH VIL VOH VOL
(1) (2)
Parameter
Output supply voltage High-level input voltage Low-level input voltage High-level output voltage Low-level output voltage
Conditions
Minimum
2.375 1.7 -0.3
Maximum
2.625 4.0 0.7
Unit
V V V V
IOH = -1mA (2) IOL = 1 mA (2)
2.0 0.4
V
Notes to Table 5-7:
Stratix II devices VC C I O voltage level support of 2.5 -5% is narrower than defined in the Normal Range of the EIA/JEDEC standard. This specification is supported across all the programmable drive settings available for this I/O standard as shown in Table 2-17 on page 2-85.
Table 5-8. 1.8-V I/O Specifications Symbol
VCCIO (1) VI H VIL VOH VOL
(1) (2)
Parameter
Output supply voltage High-level input voltage Low-level input voltage High-level output voltage Low-level output voltage
Conditions
Minimum
1.71 0.65 x VCCIO -0.3
Maximum
1.89 2.25 0.35 x VCCIO
Unit
V V V V
IOH = -2 mA (2) IOL = 2 mA (2)
VCCIO - 0.45 0.45
V
Notes to Table 5-8:
The Stratix II device family's VC C I O voltage level support of 1.8 -5% is narrower than defined in the Normal Range of the EIA/JEDEC standard. This specification is supported across all the programmable drive settings available for this I/O standard as shown in Table 2-17 on page 2-85.
Table 5-9. 1.5-V I/O Specifications (Part 1 of 2) Symbol
VCCIO (1) VI H VIL VOH
Parameter
Output supply voltage High-level input voltage Low-level input voltage High-level output voltage
Conditions
Minimum
1.425 0.65 x VCCIO -0.3 0.75 x VCCIO
Maximum
1.575 VCCIO + 0.3 0.35 x VCCIO
Unit
V V V V
IOH = -2 mA (2)
Altera Corporation March 2005
5-5 Stratix II Device Handbook, Volume 1
Operating Conditions
Table 5-9. 1.5-V I/O Specifications (Part 2 of 2) Symbol
VOL
(1) (2)
Parameter
Low-level output voltage
Conditions
IOL = 2 mA (2)
Minimum
Maximum
0.25 x VCCIO
Unit
V
Notes to Table 5-7:
The Stratix II device family's VC C I O voltage level support of 1.5 -5% is narrower than defined in the Normal Range of the EIA/JEDEC standard. This specification is supported across all the programmable drive settings available for this I/O standard as shown in Table 2-17 on page 2-85.
Figures 5-1 and 5-2 show receiver input and transmitter output waveforms, respectively, for all differential I/O standards (LVDS, LVPECL, and HyperTransport technology). Figure 5-1. Receiver Input Waveforms for Differential I/O Standards
Single-Ended Waveform Positive Channel (p) = VIH VID Negative Channel (n) = VIL VCM Ground
Differential Waveform
VID p-n=0V VID (Peak-to-peak) VID
5-6 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Figure 5-2. Transmitter Output Waveforms for Differential I/O Standards
Single-Ended Waveform Positive Channel (p) = VOH VOD Negative Channel (n) = VOL VCM Ground
Differential Waveform
VOD p-n=0V VOD
Altera Corporation March 2005
5-7 Stratix II Device Handbook, Volume 1
Operating Conditions
Table 5-10. 2.5-V LVDS I/O Specifications Symbol
VCCIO
Parameter
I/O supply voltage for left and right I/O banks (1, 2, 5, and 6) Output/feedback pins in PLL banks 9, 10, 11, and 12 (1)
Conditions
Minimum
2.375
Typical
2.5
Maximum
2.625
Unit
V
3.135 300 200 RL = 100 250
3.3 600
3.465 1,000 1,800
V mV mV mV mV V mV
VID (peak- Input differential voltage swing (single-ended) to-peak) VICM VOD VOD VOCM VOCM RL Input common mode voltage Output differential voltage (single-ended)
375
550 50
Change in VOD between high RL = 100 and low Output common mode voltage Change in VOCM between high and low Receiver differential input discrete resistor (external to Stratix devices) RL = 100 RL = 100 90 100 1.125 1.25
1.375 50 110
Notes to Tables 5-10:
(1) The top and bottom clock input differential buffers in I/O banks 3, 4, 7, and 8 are powered by VCCINT, not VCCIO. The PLL clock output/feedback differential buffers are powered by VCC_PLL_OUT. For differential clock output/feedback operation, VCC_PLL_OUT should be connected to 3.3 V.
5-8 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-11. LVPECL Specifications Symbol
VCCIO (1)
Parameter
I/O supply voltage
Conditions
Minimum
3.135 300 1.0
Typical
3.3 600
Maximum
3.465 1,000 2.0
Unit
V mV V mV mV
VID (peak- Input differential voltage swing (single-ended) to-peak) VICM VOD VOCM RL Input common mode voltage Output differential voltage (single-ended) Output common mode voltage Receiver differential input resistor RL = 100 RL = 100
525 525 90
700 700 100
970 970 110
Notes to Table 5-11:
(1) The top and bottom clock input differential buffers in I/O banks 3, 4, 7, and 8 are powered by VCCINT, not VCCIO. The PLL clock output/feedback differential buffers are powered by VCC_PLL_OUT. For differential clock output/feedback operation, VCC_PLL_OUT should be connected to 3.3 V. This specification is pending device characterization.
(2)
Table 5-12. HyperTransport Technology Specifications Symbol
VCCIO
Parameter
I/O supply voltage for left and right I/O banks (1, 2, 5, and 6) Output/feedback pins in PLL banks 9, 10, 11, and 12 (1)
Conditions
Minimum
2.375 3.135 300 385 400
Typical
2.5 3.3 600 600 600
Maximum
2.625 3.465 900 845 820 75
Unit
V V mV mV mV mV mV mV
VID (peak- Input differential voltage swing RL = 100 (single-ended) to-peak) VICM VOD VOD VOCM VOCM RL Input common mode voltage Output differential voltage (single-ended) Change in VOD between high and low RL = 100 RL = 100 RL = 100
Output common mode voltage RL = 100 Change in VOCM between high and low Receiver differential input resistor RL = 100
440
600
780 50
90
100
110
Note to Table 5-12:
(1) The top and bottom clock input differential buffers in I/O banks 3, 4, 7, and 8 are powered by VCCINT, not VCCIO. The PLL clock output/feedback differential buffers are powered by VCC_PLL_OUT. For differential clock output/feedback operation, VCC_PLL_OUT should be connected to 3.3 V.
Altera Corporation March 2005
5-9 Stratix II Device Handbook, Volume 1
Operating Conditions
Table 5-13. 3.3-V PCI Specifications Symbol
VCCIO VIH VIL VOH VOL
Parameter
Output supply voltage High-level input voltage Low-level input voltage High-level output voltage Low-level output voltage
Conditions
Minimum
3.0 0.5 x VCCIO -0.3
Typical
3.3
Maximum
3.6 VCCIO + 0.5 0.3 x VCCIO 0.1 x VCCIO
Unit
V V V V V
IOUT = -500 A IOUT = 1,500 A
0.9 x VCCIO
Table 5-14. PCI-X Mode 1 Specifications Symbol
VCCIO VIH VIL VIPU VOH VOL
Parameter
Output supply voltage High-level input voltage Low-level input voltage Input pull-up voltage High-level output voltage Low-level output voltage
Conditions
Minimum
3.0 0.5 x VCCIO -0.3 0.7 x VCCIO
Typical
Maximum
3.6 VCCIO + 0.5 0.35 x VCCIO
Unit
V V V V V
IOUT = -500 A IOUT = 1,500 A
0.9 x VCCIO 0.1 x VCCIO
V
Table 5-15. SSTL-18 Class I Specifications Symbol
VCCIO VREF VTT VIH(DC) VIL(DC) VIH(AC) VIL(AC) VOH VOL
(1)
Parameter
Output supply voltage Reference voltage Termination voltage High-level DC input voltage Low-level DC input voltage High-level AC input voltage Low-level AC input voltage High-level output voltage Low-level output voltage
Conditions
Minimum
1.71 0.855 VREF - 0.04 VREF + 0.125
Typical
1.8 0.9 VREF
Maximum
1.89 0.945 VREF + 0.04
Unit
V V V V
VREF - 0.125 VREF + 0.25 VREF - 0.25 IOH = -6.7 mA (1) IOL = 6.7 mA (1) VTT + 0.475 VTT - 0.475
V V V V V
Notes to Table 5-15:
This specification is supported across all the programmable drive settings available for this I/O standard as shown in Table 2-17 on page 2-85.
5-10 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-16. SSTL-18 Class II Specifications Symbol
VCCIO VREF VTT VIH(DC) VIL(DC) VIH(AC) VIL(AC) VOH VOL
(1)
Parameter
Output supply voltage Reference voltage Termination voltage High-level DC input voltage Low-level DC input voltage High-level AC input voltage Low-level AC input voltage High-level output voltage Low-level output voltage
Conditions
Minimum
1.71 0.855 VREF - 0.04 VREF + 0.125
Typical
1.8 0.9 VREF
Maximum
1.89 0.945 VREF + 0.04
Unit
V V V V
VREF - 0.125 VREF + 0.25 VREF - 0.25 IOH = -13.4 mA (1) IOL = 13.4 mA (1) VCCIO - 0.28 0.28
V V V V V
Notes to Table 5-16:
This specification is supported across all the programmable drive settings available for this I/O standard as shown in Table 2-17 on page 2-85.
Table 5-17. SSTL-18 Differential Specifications Symbol
VCCIO VSWING
(DC)
Parameter
Output supply voltage DC differential input voltage AC differential input cross point voltage AC differential input voltage Input clock signal offset voltage Input clock signal offset voltage variation AC differential cross point voltage
Conditions
Minimum
1.71 0.25 (VCCIO/2) - 0.175 0.5
Typical
1.8
Maximum
1.89
Unit
V V
VX (AC) VSWING (AC) VISO VISO VOX(AC)
(VCCIO/2) + 0.175
V V
0.5 x VCCIO 200 (VCCIO/2) - 0.125 (VCCIO/2) + 0.125
V mV V
Altera Corporation March 2005
5-11 Stratix II Device Handbook, Volume 1
Operating Conditions
Table 5-18. SSTL-2 Class I Specifications Symbol
VCCIO VTT VREF VIH VIL VOH VOL
(1)
Parameter
Output supply voltage Termination voltage Reference voltage High-level input voltage Low-level input voltage High-level output voltage Low-level output voltage
Conditions
Minimum
2.375 VREF - 0.04 1.188 VREF + 0.18 -0.3
Typical
2.5 VREF 1.25
Maximum
2.625 VREF + 0.04 1.313 3.0 VREF - 0.18
Unit
V V V V V V
IOH = -8.1 mA (1) IOL = 8.1 mA (1)
VTT + 0.57 VTT - 0.57
V
Notes to Table 5-18:
This specification is supported across all the programmable drive settings available for this I/O standard as shown in Table 2-17 on page 2-85.
Table 5-19. SSTL-2 Class II Specifications Symbol
VCCIO VTT VREF VIH VIL VOH VOL
(1)
Parameter
Output supply voltage Termination voltage Reference voltage High-level input voltage Low-level input voltage High-level output voltage Low-level output voltage
Conditions
Minimum
2.375 VREF - 0.04 1.188 VREF + 0.18 -0.3
Typical
2.5 VREF 1.25
Maximum
2.625 VREF + 0.04 1.313 VCCIO + 0.3 VREF - 0.18
Unit
V V V V V V
IOH = -16.4 mA (1) IOL = 16.4 mA (1)
VTT + 0.76 VTT - 0.76
V
Notes to Table 5-19:
This specification is supported across all the programmable drive settings available for this I/O standard as shown in Table 2-17 on page 2-85.
5-12 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-20. SSTL-2 Differential Specifications Symbo l
VCCIO VSWING
(DC)
Parameter
Output supply voltage DC differential input voltage AC differential input cross point voltage AC differential input voltage Input clock signal offset voltage Input clock signal offset voltage variation AC differential output cross point voltage
Conditions
Minimum
2.375 0.36 (VCCIO/2) - 0.2 0.7
Typical
2.5
Maximum
2.625
Unit
V V
VX (AC) VSWING
(AC)
(VCCIO/2) + 0.2
V V
VISO VISO VOX(AC)
0.5 x VCCIO 200 (VCCIO/2) - 0.2 (VCCIO/2) + 0.2
V mV V
Table 5-21. 1.5-V HSTL Class I Specifications Symbol
VCCIO VREF VTT VIH (DC) VIL (DC) VIH (AC) VIL (AC) VOH VOL
(1)
Parameter
Output supply voltage Input reference voltage Termination voltage DC high-level input voltage DC low-level input voltage AC high-level input voltage AC low-level input voltage High-level output voltage Low-level output voltage
Conditions
Minimum
1.425 0.713 0.713 VREF + 0.1 -0.3 VREF + 0.2
Typical
1.5 0.75 0.75
Maximum
1.575 0.788 0.788
Unit
V V V V
VREF - 0.1
V V
VREF - 0.2 IOH = 8 mA (1) IOH = -8 mA (1) VCCIO - 0.4 0.4
V V V
Notes to Table 5-21:
This specification is supported across all the programmable drive settings available for this I/O standard as shown in Table 2-17 on page 2-85.
Altera Corporation March 2005
5-13 Stratix II Device Handbook, Volume 1
Operating Conditions
Table 5-22. 1.5-V HSTL Class II Specifications Symbol
VCCIO VREF VTT VIH (DC) VIL (DC) VIH (AC) VIL (AC) VOH VOL
(1)
Parameter
Output supply voltage Input reference voltage Termination voltage DC high-level input voltage DC low-level input voltage AC high-level input voltage AC low-level input voltage High-level output voltage Low-level output voltage
Conditions
Minimum
1.425 0.713 0.713 VREF + 0.1 -0.3 VREF + 0.2
Typical
1.50 0.75 0.75
Maximum
1.575 0.788 0.788
Unit
V V V V
VREF - 0.1
V V
VREF - 0.2 IOH = 16 mA (1) IOH = -16 mA (1) VCCIO - 0.4 0.4
V V V
Notes to Table 5-22:
This specification is supported across all the programmable drive settings available for this I/O standard as shown in Table 2-17 on page 2-85.
Table 5-23. 1.5-V Differential HSTL Specifications Symbol
VCCIO VDIF (DC) VCM (DC) VDIF (AC) VOX (AC)
Parameter
I/O supply voltage DC input differential voltage DC common mode input voltage AC differential input voltage AC differential cross point voltage
Conditions
Minimum
1.425 0.2 0.68 0.4 0.68
Typical
1.5
Maximum
1.575
Unit
V V
0.9
V V
0.9
V
5-14 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-24. 1.8-V HSTL Class I Specifications Symbol
VCCIO VREF VTT VIH (DC) VIL (DC) VIH (AC) VIL (AC) VOH VOL
(1)
Parameter
Output supply voltage Input reference voltage Termination voltage DC high-level input voltage DC low-level input voltage AC high-level input voltage AC low-level input voltage High-level output voltage Low-level output voltage
Conditions
Minimum
1.71 0.85 0.85 VREF + 0.1 -0.3 VREF + 0.2
Typical
1.80 0.90 0.90
Maximum
1.89 0.95 0.95
Unit
V V V V
VREF - 0.1
V V
VREF - 0.2 IOH = 8 mA (1) IOH = -8 mA (1) VCCIO - 0.4 0.4
V V V
Notes to Table 5-24:
This specification is supported across all the programmable drive settings available for this I/O standard as shown in Table 2-17 on page 2-85.
Table 5-25. 1.8-V HSTL Class II Specifications Symbol
VCCIO VREF VTT VIH (DC) VIL (DC) VIH (AC) VIL (AC) VOH VOL
(1)
Parameter
Output supply voltage Input reference voltage Termination voltage DC high-level input voltage DC low-level input voltage AC high-level input voltage AC low-level input voltage High-level output voltage Low-level output voltage
Conditions
Minimum
1.71 0.85 0.85 VREF + 0.1 -0.3 VREF + 0.2
Typical
1.80 0.90 0.90
Maximum
1.89 0.95 0.95
Unit
V V V V
VREF - 0.1
V V
VREF - 0.2 IOH = 16 mA (1) IOH = -16 mA (1) VCCIO - 0.4 0.4
V V V
Notes to Table 5-25:
This specification is supported across all the programmable drive settings available for this I/O standard as shown in Table 2-17 on page 2-85.
Altera Corporation March 2005
5-15 Stratix II Device Handbook, Volume 1
Operating Conditions
Table 5-26. 1.8-V Differential HSTL Specifications Symbol
VCCIO VDIF (DC) VCM (DC) VDIF (AC) VOX (AC)
Parameter
I/O supply voltage DC input differential voltage DC common mode input voltage AC differential input voltage AC differential cross point voltage
Conditions
Minimum
1.71 0.2 0.68 0.4 0.68
Typical
1.80
Maximum
1.89
Unit
V V
0.9
V V
0.9
V
Bus Hold Specifications
Table 5-27 shows the Stratix II device family bus hold specifications.
Table 5-27. Bus Hold Parameters VCCIO Level Parameter Conditions 1.5 V Min
Low sustaining current VIN > VIL (maximum) (1) (1) (1) (1)
1.8 V Min
30 -30 200 -200
2.5 V Min
50 -50 300 -300
3.3 V Min
70 -70 500 -500
Unit
Max
Max
Max
Max
A A A A
High sustaining VIN < VIH current (minimum) Low overdrive current High overdrive current 0 V < VIN < VCCIO 0 V < VIN < VCCIO
Notes to Table 5-27:
(1) This specification is pending device characterization.
5-16 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
On-Chip Termination Specifications
Tables 5-28 and 5-29 define the specification for internal termination resistance tolerance when using series or differential on-chip termination.
Table 5-28. Series On-Chip Termination Specification for Top & Bottom I/O Banks (3, 4, 7, and 8) Resistance Tolerance Symbol
25- RS 3.3/2.5
Description
Internal series termination with calibration (25- setting) Internal series termination without calibration (25- setting)
Conditions
VC C I O = 3.3/2.5V VC C I O = 3.3/2.5V VC C I O = 3.3/2.5V VC C I O = 3.3/2.5V VC C I O = 1.8V VC C I O = 1.8V VC C I O = 1.8 V VC C I O = 1.8V VC C I O = 1.5V VC C I O = 1.5V
Commercial Max
5 30 5 30 6 30 6 30 (1) 36
Industrial Max
10 (1) 10 (1) 10 (1) 10 (1) (1) (1)
Unit
% % % % % % % % % %
50- RS 3.3/2.5
Internal series termination with calibration (50- setting) Internal series termination without calibration (50- setting)
25- RS 1.8
Internal series termination with calibration (25- setting) Internal series termination without calibration (25- setting)
50- RS 1.8
Internal series termination with calibration (50- setting) Internal series termination without calibration (50- setting)
50- RS 1.5
Internal series termination with calibration (50- setting) Internal series termination without calibration (50- setting)
Note for Table 5-28:
(1) This specification is pending device characterization.
Altera Corporation March 2005
5-17 Stratix II Device Handbook, Volume 1
Operating Conditions
Table 5-29. Series & Differential On-Chip Termination Specification for Left & Right I/O Banks (1, 2, 5, and 6) Resistance Tolerance Symbol
25- RS 3.3/2.5 50- RS 3.3/2.5/1.8 RD
Description
Internal series termination without calibration (25- setting) Internal series termination without calibration (50- setting) Internal differential termination for LVDS or HyperTransport technology
Conditions
VC C I O = 3.3/2.5V VC C I O = 3.3/2.5/1.8V
Commercial Industrial Max Max
30 30 (1) (1) (1) (1)
Unit
% % %
Note to Table 5-29:
(1) This specification is pending device characterization.
Pin Capacitance
Table 5-30 shows the Stratix II device family pin capacitance.
Table 5-30. Stratix II Device Capacitance Symbol
CI O T B CI O L R
Parameter
Input capacitance on I/O pins in I/O banks 3, 4, 7, and 8. Input capacitance on I/O pins in I/O banks 1, 2, 5, and 6, including high-speed differential receiver and transmitter pins. Input capacitance on top/bottom clock input pins: CLK[4..7] and CLK[12..15]. Input capacitance on left/right clock inputs: CLK0, CLK2,
Minimum
Typical
5.0 6.1
Maximum Unit
(1) (1) pF pF
CC L K T B CC L K L R
6.0 6.1 3.3 6.7
(1) (1) (1) (1)
pF pF pF pF
CLK8, CLK10.
CC L K L R + Input capacitance on left/right clock inputs: CLK1, CLK3, CLK9, and CLK11. CO U T F B Input capacitance on dual-purpose clock output/feedback pins in PLL banks 9, 10, 11, and 12.
Notes to Table 5-30:
(1) This specification is pending device characterization.
5-18 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Power Consumption
Altera(R) offers two ways to calculate power for a design: the Excel-based PowerPlay Early Power Estimator power calculator and the Quartus II PowerPlay Power Analyzer feature. The interactive Excel-based PowerPlay Early Power Estimator is typically used prior to designing the FPGA in order to get an estimate of device power. The Quartus II PowerPlay Power Analyzer provides better quality estimates based on the specifics of the design after place-androute is complete. The Power Analyzer can apply a combination of userentered, simulation-derived and estimated signal activities which, combined with detailed circuit models, can yield very accurate power estimates. In both cases, these calculations should only be used as an estimation of power, not as a specification.
f
For more information on PowerPlay tools, refer to the PowerPlay Early Power Estimator User Guide and the PowerPlay Early Power Estimator and PowerPlay Power Analyzer chapters in Volume 3 of the Quartus II Handbook. The PowerPlay Early Power Estimator is available on the Altera web site at www.altera. com.
Timing Model
The DirectDriveTM technology and MultiTrack interconnect ensure predictable performance, accurate simulation, and accurate timing analysis across all Stratix II device densities and speed grades. This section describes and specifies the performance, internal, external, and PLL timing specifications. All specifications are representative of worst-case supply voltage and junction temperature conditions. 1 The timing numbers listed in the tables of this section are extracted from the Quartus II software version 4.2. There are performance numbers shown throughout this handbook that reflect increased performance based on device characterization that will be incorporated in the Quartus II software version 5.0.
Preliminary & Final Timing
Timing models can have either preliminary or final status. The Quartus II software issues an informational message during the design compilation if the timing models are preliminary. Table 5-30 shows the status of the Stratix II device timing models.
Altera Corporation March 2005
5-19 Stratix II Device Handbook, Volume 1
Timing Model
Preliminary status means the timing model is subject to change. Initially, timing numbers are created using simulation results, process data, and other known parameters. These tests are used to make the preliminary numbers as close to the actual timing parameters as possible. Final timing numbers are based on actual device operation and testing. These numbers reflect the actual performance of the device under worstcase voltage and junction temperature conditions.
Table 5-31. Stratix II Device Timing Model Status Device
EP2S15 EP2S30 EP2S60 EP2S90 EP2S130 EP2S180
Preliminary v v v v v v
Final
I/O Timing Measurement Methodology
Different I/O standards require different baseline loading techniques for reporting timing delays. Altera characterizes timing delays with the required termination for each I/O standard and with 0 pF (except for PCI which uses 10 pF) loading and the timing is specified up to the output pin of the FPGA device. The Quartus II software calculates the I/O timing for each I/O standard with a default baseline loading as specified by the I/O standards. The following measurements are made during device characterization. Altera measures clock-to-output delays (tCO) at worst-case process, minimum voltage, and maximum temperature (PVT) for default loading conditions shown in Table 5-32. Use the following equations to calculate clock pin to output pin timing for Stratix II devices. tCO from clock pin to I/O pin = delay from clock pad to I/O output register + IOE output register clock-to-output delay + delay from output register to output pin + I/O output delay txz/tzx from clock pin to I/O pin = delay from clock pad to I/O output register + IOE output register clock-to-output delay + delay from output register to output pin + I/O output delay + output enable pin delay
5-20 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Simulation using IBIS models is required to determine the delays on the PCB traces in addition to the output pin delay timing reported by Quartus II and the timing model in the device handbook. 1. Simulate the output driver of choice into the generalized test setup, using values from Table 5-32. Record the time to VMEAS. Simulate the output driver of choice into the actual PCB trace and load, using the appropriate IBIS model or capacitance value to represent the load. Record the time to VMEAS. Compare the results of steps 2 and 4. The increase or decrease in delay should be added to or subtracted from the I/O Standard Output Adder delays to yield the actual worst-case propagation delay (clock-to-input) of the PCB trace.
2. 3.
4. 5.
Quartus II reports the timing with the conditions shown in Table 5-32 using the above equation. Figure 5-3 shows the model of the circuit that is represented by Quartus II output timing. Figure 5-3. Output Delay Timing Reporting Setup Modeled by Quartus II
VTT VCCIO RT Output Buffer
Output
Outputp RD
RS CL
GND
VMEAS
Outputn
GND
Notes to Figure 5-3:
(1) Output pin timing is reported at the output pin of the FPGA device. Additional delays for loading and board trace delay need to be accounted for with IBIS model simulations. VCCPD is 3.085 V unless otherwise specified. VCCINT is 1.12 V unless otherwise specified.
(2) (3)
Figures 5-4 and 5-5 show the measurement setup for output disable and output enable timing.
Altera Corporation March 2005
5-21 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-32. Output Timing Measurement Methodology for Output Pins Loading and Termination I/O Standard RS ()
LVTTL (4) LVCMOS (4) 2.5 V (4) 1.8 V (4) 1.5 V (4) PCI (5) PCI-X (5) SSTL-2 class I SSTL-2 class II SSTL-18 class I SSTL-18 class II 1.8-V HSTL class I 1.8-V HSTL class II 1.5-V HSTL class I 1.5-V HSTL class II Differential SSTL-2 class I Differential SSTL-2 class II Differential SSTL-18 class I Differential SSTL-18 class II 1.5-V differential HSTL class I 1.5-V differential HSTL class II 1.8-V differential HSTL class I 1.8-V differential HSTL class II LVDS HyperTransport LVPECL Notes to Table 5-32:
(1) (2) (3) (4) (5)
Notes (1), (2), (3) Measurement Point VTT (V)
3.135 3.135 2.375 1.710 1.425 2.970 2.970 1.123 1.123 0.790 0.790 0.790 0.790 0.648 0.648 1.123 1.123 0.790 0.790 0.648 0.648 0.790 0.790
RD ()
RT ()
VCCIO (V)
3.135 3.135 2.375 1.710 1.425 2.970 2.970
CL (pF)
0 0 0 0 0 10 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
VMEAS (V)
1.5675 1.5675 1.1875 0.855 0.7125 1.485 1.485 1.1625 1.1625 0.83 0.83 0.83 0.83 0.6875 0.6875 1.1625 1.1625 0.83 0.83 0.6875 0.6875 0.83 0.83 1.1625 1.1625 1.5675
25 25 25 25
50 25 50 25 50 25 50 25
2.325 2.325 1.660 1.660 1.660 1.660 1.375 1.375 2.325 2.325 1.660 1.660 1.375 1.375 1.660 1.660 2.325 2.325 3.135
25 25 25 25
50 25 50 25 50 25 50 25 100 100 100
Input measurement point at internal node is 0.5 x VCCINT. Output measuring point for VMEAS at buffer output is 0.5 x VCCIO. Input stimulus edge rate is 0 to VCC in 0.2 ns (internal signal) from the driver preceding the I/O buffer. Less than 50-mV ripple on VCCIO and VCCPD, VCCINT = 1.15 V with less than 30-mV ripple VCCPD = 2.97 V, less than 50-mV ripple on VCCIO and VCCPD, VCCINT = 1.15 V
5-22 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Figure 5-4. Measurement Setup for txz
Note (1)
tXZ, Driving High to Tristate Enable OE Dout Din Din OE Disable 1/2 VCCINT "1" 100 mv Dout thz GND
100
tXZ, Driving Low to Tristate Enable OE 100 OE Dout Din Dout Din tlz "0" VCCIO 100 mv Disable 1/2 VCCINT
Note to Figure 5-4:
(1) VCCINT is 1.12 V for this measurement.
Altera Corporation March 2005
5-23 Stratix II Device Handbook, Volume 1
Timing Model
Figure 5-5. Measurement Setup for tzx
tZX, Tristate to Driving High Disable OE Dout Din 1 M Dout tzh 1/2 VCCIO Din "1" OE Enable 1/2 VCCINT
tZX, Tristate to Driving Low Disable OE 1 M OE Dout Din Dout tzl Din "0" 1/2 VCCIO Enable 1/2 VCCINT
Table 5-33 specifies the input timing measurement setup.
Table 5-33. Timing Measurement Methodology for Input Pins (Part 1 of 2) Measurement Conditions I/O Standard VCCIO (V)
LVTTL (5) LVCMOS (5) 2.5 V (5) 1.8 V (5) 1.5 V (5) PCI (6) PCI-X (6) SSTL-2 class I SSTL-2 class II SSTL-18 class I SSTL-18 class II 1.8-V HSTL class I 3.135 3.135 2.375 1.710 1.425 2.970 2.970 2.325 2.325 1.660 1.660 1.660 1.163 1.163 0.830 0.830 0.830
Notes (1)-(4) Measurement Point VMEAS (V)
1.5675 1.5675 1.1875 0.855 0.7125 1.485 1.485 1.1625 1.1625 0.83 0.83 0.83
VREF (V)
Edge Rate (ns)
3.135 3.135 2.375 1.710 1.425 2.970 2.970 2.325 2.325 1.660 1.660 1.660
5-24 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-33. Timing Measurement Methodology for Input Pins (Part 2 of 2) Measurement Conditions I/O Standard VCCIO (V)
1.8-V HSTL class II 1.5-V HSTL class I 1.5-V HSTL class II Differential SSTL-2 class I Differential SSTL-2 class II Differential SSTL-18 class I Differential SSTL-18 class II 1.5-V differential HSTL class I 1.5-V differential HSTL class II 1.8-V differential HSTL class I 1.8-V differential HSTL class II LVDS HyperTransport LVPECL Notes to Table 5-33:
(1) (2) (3) (4) (5) (6)
Notes (1)-(4) Measurement Point VMEAS (V)
0.83 0.6875 0.6875 1.1625 1.1625 0.83 0.83 0.6875 0.6875 0.83 0.83 1.1625 1.1625 1.5675
VREF (V)
0.830 0.688 0.688 1.163 1.163 0.830 0.830 0.688 0.688 0.830 0.830
Edge Rate (ns)
1.660 1.375 1.375 2.325 2.325 1.660 1.660 1.375 1.375 1.660 1.660 0.100 0.400 0.100
1.660 1.375 1.375 2.325 2.325 1.660 1.660 1.375 1.375 1.660 1.660 2.325 2.325 3.135
Input buffer sees no load at buffer input. Input measuring point at buffer input is 0.5 x VCCIO. Output measuring point is 0.5 x VCC at internal node. Input edge rate is 1 V/ns. Less than 50-mV ripple on VCCIO and VCCPD, VCCINT = 1.15 V with less than 30-mV ripple VCCPD = 2.97 V, less than 50-mV ripple on VCCIO and VCCPD, VCCINT = 1.15 V
Performance
Table 5-34 shows Stratix II performance for some common designs. All performance values were obtained with the Quartus II software compilation of library of parameterized modules (LPM), or MegaCore(R) functions for the finite impulse response (FIR) and fast Fourier transform (FFT) designs.
Altera Corporation March 2005
5-25 Stratix II Device Handbook, Volume 1
Timing Model
1
The performance numbers in Table 5-34 are extracted from the Quartus II software version 4.2. There are performance numbers shown throughout this handbook that reflect increased performance based on device characterization that will be incorporated in the Quartus II software version 5.0.
Table 5-34. Stratix II Performance Notes (Part 1 of 6) Resources Used Applications ALUTs
LE 16-to-1 multiplexer (2) 32-to-1 multiplexer (2) 16-bit counter 64-bit counter TriMatrix Memory M512 block TriMatrix Memory M4K block Simple dual-port RAM 32 x 18 bit FIFO 32 x 18 bit Simple dual-port RAM 128 x 36 bit True dual-port RAM 128 x 18 bit FIFO 128 x 36 bit 21 38 16 64 0 22 0 0 22
Notes (1) Performance -3 Speed Grade
422.11 422.11 422.11 239.0 380.22 380.22 400.0 400.0 400.0
TriMatrix Memory Blocks
0 0 0 0 1 1 1 1 1
DSP Blocks
0 0 0 0 0 0 0 0 0
-4 Speed Grade
422.11 391.23 422.11 209.42 345.78 345.78 347.94 347.94 347.94
-5 Speed Units Grade
358.8 344.82 358.8 174.06 305.99 305.99 290.02 290.02 290.02 MHz MHz MHz MHz MHz MHz MHz MHz MHz
5-26 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-34. Stratix II Performance Notes (Part 2 of 6) Resources Used Applications ALUTs
TriMatrix Memory M-RAM block Single port RAM 4K x 144 bit Simple dual-port RAM 4K x 144 bit True dual-port RAM 4K x 144 bit Single port RAM 8K x 72 bit Simple dual-port RAM 8K x 72 bit True dual-port RAM 8K x 72 bit Single port RAM 16K x 36 bit Simple dual-port RAM 16K x 36 bit True dual-port RAM 16K x 36 bit Single port RAM 32K x 18 bit Simple dual-port RAM 32K x 18 bit True dual-port RAM 32K x 18 bit Single port RAM 64K x 9 bit Simple dual-port RAM 64K x 9 bit True dual-port RAM 64K x 9 bit 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Notes (1) Performance -3 Speed Grade
400.0 400.0 400.0 400.0 400.0 400.0 400.0 400.0 400.0 400.0 400.0 400.0 400.0 400.0 400.0
TriMatrix Memory Blocks
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
DSP Blocks
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
-4 Speed Grade
348.43 348.43 348.43 348.43 348.43 348.43 348.43 348.43 348.43 348.43 348.43 348.43 348.43 348.43 348.43
-5 Speed Units Grade
289.85 289.85 289.85 289.85 289.85 289.85 289.85 289.85 289.85 289.85 289.85 289.85 289.85 289.85 289.85 MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz
Altera Corporation March 2005
5-27 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-34. Stratix II Performance Notes (Part 3 of 6) Resources Used Applications ALUTs
DSP block 9 x 9-bit multiplier (3) 18 x 18-bit multiplier (3) 36 x 36-bit multiplier (3) 36 x 36-bit multiplier (4) 18-bit, four tap FIR filter Larger Designs 8-bit,16 tap parallel FIR filter 8-bit, 1024-point, streaming, three multipliers and five adders FFT function 8-bit, 1024-point, streaming, four multipliers and two adders FFT function 8-bit, 1024-point, single output, one parallel FFT engine, burst, three multipliers and five adders FFT function 8-bit, 1024-point, single output, one parallel FFT engine, burst, four multipliers and two adders FFT function 0 0 0 0 0 58 2976
Notes (1) Performance -3 Speed Grade
420.16 420.16 250.0 420.16 420.16 254.77 308.83
TriMatrix Memory Blocks
0 0 0 0 0 0 19
DSP Blocks
1 1 1 1 1 4 9
-4 Speed Grade
365.49 365.49 217.48 365.49 365.49 222.41 270.27
-5 Speed Units Grade
304.5 304.5 181.19 304.5 304.5 175.65 219.15 MHz MHz MHz MHz MHz MHz MHz
2781
19
12
377.78
338.18
279.56
MHz
984
5
3
400.0
343.17
235.96
MHz
919
5
4
400.0
347.94
290.02
MHz
5-28 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-34. Stratix II Performance Notes (Part 4 of 6) Resources Used Applications ALUTs
Larger Designs 8-bit, 1024-point, single output, two parallel FFT engines, burst, three multiplier and five adders FFT function 8-bit, 1024-point, single output, two parallel FFT engines, burst, four multipliers and two adders FFT function 8-bit, 1024-point, quadrant output, one parallel FFT engine, burst, three multipliers and five adders FFT function 8-bit, 1024-point, quadrant output, one parallel FFT engine, burst, four multipliers and two adders FFT function 8-bit, 1024-point, quadrant output, two parallel FFT engines, burst, three multipliers and five adders FFT function 8-bit, 1024-point, quadrant output, two parallel FFT engines, burst, four multipliers and two adders FFT function 1725
Notes (1) Performance -3 Speed Grade
320.51
TriMatrix Memory Blocks
7
DSP Blocks
6
-4 Speed Grade
279.95
-5 Speed Units Grade
269.39 MHz
1594
7
8
389.25
338.52
277.93
MHz
2361
7
9
356.25
278.78
259.67
MHz
2165
7
12
276.16
330.68
283.76
MHz
3996
11
18
293.59
304.87
193.38
MHz
3604
11
24
360.75
335.12
279.17
MHz
Altera Corporation March 2005
5-29 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-34. Stratix II Performance Notes (Part 5 of 6) Resources Used Applications ALUTs
Larger Designs 8-bit, 1024-point, quadrant output, four parallel FFT engines, burst, three multipliers and five adders FFT function 8-bit, 1024-point, quadrant output, four parallel FFT engines, burst, four multipliers two adders FFT function 8-bit, 1024-point, quadrant output, one parallel FFT engine, buffered burst, three multipliers and adders FFT function 8-bit, 1024-point, quadrant output, one parallel FFT engine, buffered burst, four multipliers and two adders FFT function 8-bit, 1024-point, quadrant output, two parallel FFT engines, buffered burst, three multipliers five adders FFT function 8-bit, 1024-point, quadrant output, two parallel FFT engines, buffered burst four multipliers and two adders FFT function 6850
Notes (1) Performance -3 Speed Grade
277.08
TriMatrix Memory Blocks
22
DSP Blocks
36
-4 Speed Grade
268.88
-5 Speed Units Grade
227.32 MHz
6067
22
48
334.44
308.54
253.67
MHz
2730
15
9
323.2
311.33
269.61
MHz
2534
15
12
400.0
322.26
278.08
MHz
4358
19
18
329.92
272.25
227.01
MHz
3966
19
24
373.97
320.1
209.59
MHz
5-30 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-34. Stratix II Performance Notes (Part 6 of 6) Resources Used Applications ALUTs
Larger Designs 8-bit, 1024-point, quadrant output, four parallel FFT engines, buffered burst, three multipliers five adders FFT function 8-bit, 1024-point, quadrant output, four parallel FFT engines, buffered burst, four multipliers and two adders FFT function Notes for Table 5-34:
(1) (2) (3) (4)
Notes (1) Performance -3 Speed Grade
284.25
TriMatrix Memory Blocks
38
DSP Blocks
36
-4 Speed Grade
249.62
-5 Speed Units Grade
189.1 MHz
7385
6601
38
48
344.82
279.32
212.63
MHz
These design performance numbers were obtained using the Quartus II software version 4.2. This application uses registered inputs and outputs. This application uses registered multiplier input and output stages within the DSP block. This application uses registered multiplier input, pipeline, and output stages within the DSP block.
Internal Timing Parameters
See Tables 5-35 through 5-40 for internal timing parameters.
Table 5-35. LE_FF Internal Timing Microparameters -3 Speed Grade Symbol
tS U tH tC O tC L R tP R E tC L K L tC L K H
-4 Speed Grade Min
105 171
-5 Speed Grade Unit Min
126 206
Parameter Min
LE register setup time before clock LE register hold time after clock LE register clock-to-output delay Minimum clear pulse width Minimum preset pulse width Minimum clock low time Minimum clock high time 206 206 618 618 91 149 95 236 236 710 710
Max
Max
Max
ps ps 132 ps ps ps ps ps
110 284 284 852 852
Altera Corporation March 2005
5-31 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-36. IOE Internal Timing Microparameters -3 Speed Grade -4 Speed Grade -5 Speed Grade Symbol
tS U tH tC O tP I N 2 C O M B O U T _ R tP I N 2 C O M B O U T _ C tC O M B I N 2 P I N _ R tC O M B I N 2 P I N _ C tC L R tP R E tC L K L tC L K H
Parameter Min
IOE input and output register setup time before clock IOE input and output register hold time after clock IOE input and output register clock-to-output delay Row input pin to IOE combinational output Column input pin to IOE combinational output Row IOE data input to combinational output pin Column IOE data input to combinational output pin Minimum clear pulse width Minimum preset pulse width Minimum clock low time Minimum clock high time 200 200 600 600 229 690 690 72 72 169 529 748 1,678 1,675
Unit Max Min
82 82 194 608 860 1,929 1,925 229 276 827 827
Max
Min
99 99
Max
ps ps 233 730 1,032 2,314 2,311 276 ps ps ps ps ps ps ps ps ps
Table 5-37. DSP Block Internal Timing Microparameters (Part 1 of 2) -3 Speed Grade -4 Speed Grade -5 Speed Grade Symbol
tS U
Parameter Min
Input, pipeline, and output register setup time before clock Input, pipeline, and output register hold time after clock Input, pipeline, and output register clock-to-output delay Input Register to DSP Block pipeline register in 9 x 9-bit mode Input Register to DSP Block pipeline register in 18 x 18-bit mode 50
Unit Max Min
57
Max
Min
69
Max
ps
tH tC O tI N R E G 2 P I P E 9
180 0 2,030
206 0 2,334
248 0 2,801
ps ps ps
tI N R E G 2 P I P E 1 8
2,010
2,311
2,773
ps
5-32 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-37. DSP Block Internal Timing Microparameters (Part 2 of 2) -3 Speed Grade -4 Speed Grade -5 Speed Grade Symbol
tI N R E G 2 P I P E 3 6
Parameter Min
Input Register to DSP Block pipeline register in 36 x 36-bit mode
Unit Max
2,010
Min
Max
2,311
Min
Max
2,773 ps
tP I P E 2 O U T R E G 2 A D D DSP Block Pipeline Register to output register delay in Two-Multipliers Adder mode tP I P E 2 O U T R E G 4 A D D DSP Block Pipeline Register to output register delay in Four-Multipliers Adder mode tP D 9 tP D 1 8 tP D 3 6 tC L R tC L K L tC L K H Combinational input to output delay for 9 x 9 Combinational input to output delay for 18 x 18 Combinational input to output delay for 36 x 36 Minimum clear pulse width Minimum clock low time Minimum clock high time 2,212 1,190 1,190
1,450
1,667
2,000
ps
1,850
2,127
2,553
ps
2,880 2,990 4,450 2,543 1,368 1,368
3,312 3,438 5,117 3,052 1,642 1,642
3,973 4,125 6,140
ps ps ps ps ps ps
Table 5-38. M512 Block Internal Timing Microparameters (Part 1 of 2) Symbol
tM 5 1 2 R C tM 5 1 2 W E R E S U tM 5 1 2 W E R E H tM 5 1 2 D ATA S U tM 5 1 2 D ATA H tM 5 1 2 WA D D R S U tM 5 1 2 WA D D R H tM 5 1 2 R A D D R S U
Note (1) Unit
-3 Speed Grade -4 Speed Grade -5 Speed Grade Parameter Min
Synchronous read cycle time Write or read enable setup time before clock Write or read enable hold time after clock Data setup time before clock Data hold time after clock Write address setup time before clock Write address hold time after clock Read address setup time before clock 22 203 22 203 22 203 22
Max
2,829
Min
Max
3,134
Min
Max
3,579 ps ps ps ps ps ps ps ps
24 223 24 223 24 223 24
27 252 27 252 27 252 27
Altera Corporation March 2005
5-33 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-38. M512 Block Internal Timing Microparameters (Part 2 of 2) Symbol
tM 5 1 2 R A D D R H tM 5 1 2 D ATA C O 1 tM 5 1 2 D ATA C O 2 tM 5 1 2 C L K L tM 5 1 2 C L K H tM 5 1 2 C L R
(1)
Note (1) Unit
-3 Speed Grade -4 Speed Grade -5 Speed Grade Parameter Min
Read address hold time after clock Clock-to-output delay when using output registers Clock-to-output delay without output registers Minimum clock low time Minimum clock high time Minimum clear pulse width 1,315 1,315 144 203 478 2,865 1,446 1,446 158
Max
Min
223
Max
Min
252
Max
ps 649 3,617 ps ps ps ps ps
545 3,171 1,634 1,634 178
Note to Table 5-38:
FMAX of M512 Block obtained using the Quartus II software does not necessarily equal to 1/TM512RC.
Table 5-39. M4K Block Internal Timing Microparameters (Part 1 of 2) Symbol
tM 4 K R C tM 4 K W E R E S U tM 4 K W E R E H tM 4 K B E S U tM 4 K B E H tM 4 K D ATA A S U tM 4 K D ATA A H tM 4 K A D D R A S U tM 4 K A D D R A H tM 4 K D ATA B S U tM 4 K D ATA B H
Note (1) Unit
-3 Speed Grade -4 Speed Grade -5 Speed Grade Parameter Min
Synchronous read cycle time Write or read enable setup time before clock Write or read enable hold time after clock Byte enable setup time before clock Byte enable hold time after clock A port data setup time before clock A port data hold time after clock A port address setup time before clock A port address hold time after clock B port data setup time before clock B port data hold time after clock 22 203 22 203 22 203 22 203 22 203 22
Max
2,240
Min
Max
2,575
Min
Max
3,089 ps ps ps ps ps ps ps ps ps ps ps ps
25 233 25 233 25 233 25 233 25 233 25
30 280 30 280 30 280 30 280 30 280 30
tM 4 K R A D D R B S U B port address setup time before clock
5-34 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-39. M4K Block Internal Timing Microparameters (Part 2 of 2) Symbol
tM 4 K R A D D R B H tM 4 K D ATA C O 1 tM 4 K D ATA C O 2 tM 4 K C L K H tM 4 K C L K L tM 4 K C L R
(1)
Note (1) Unit
-3 Speed Grade -4 Speed Grade -5 Speed Grade Parameter Min
B port address hold time after clock Clock-to-output delay when using output registers Clock-to-output delay without output registers Minimum clock high time Minimum clock low time Minimum clear pulse width 1,250 1,250 144 203 526 2,460 1,437 1,437 165
Max
Min
233
Max
Min
280
Max
ps 725 3,393 ps ps ps ps ps
604 2,828 1,724 1,724 198
Note to Table 5-39:
FMAX of M4K Block obtained using the Quartus II software does not necessarily equal to 1/TM4KRC.
Table 5-40. M-RAM Block Internal Timing Microparameters (Part 1 of 2) Symbol
tM E G A R C tM E G AW E R E S U tM E G AW E R E H tM E G A B E S U tM E G A B E H tM E G A D ATA A S U tM E G A D ATA A H
Note (1) Unit
-3 Speed Grade -4 Speed Grade -5 Speed Grade Parameter Min
Synchronous read cycle time Write or read enable setup time before clock Write or read enable hold time after clock Byte enable setup time before clock Byte enable hold time after clock A port data setup time before clock A port data hold time after clock 22 203 22 203 22 203 22 203 22 203 22
Max
2,688
Min
Max
3,090
Min
Max
3,708 ps ps ps ps ps ps ps ps ps ps ps ps
25 233 25 233 25 233 25 233 25 233 25
30 280 30 280 30 280 30 280 30 280 30
tM E G A A D D R A S U A port address setup time before clock tM E G A A D D R A H tM E G A D ATA B S U tM E G A D ATA B H A port address hold time after clock B port setup time before clock B port hold time after clock
tM E G A A D D R B S U B port address setup time before clock
Altera Corporation March 2005
5-35 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-40. M-RAM Block Internal Timing Microparameters (Part 2 of 2) Symbol
tM E G A A D D R B H tM E G A D ATA C O 1 tM E G A D ATA C O 2 tM E G A C L K L tM E G A C L K H tM E G A C L R
(1)
Note (1) Unit
-3 Speed Grade -4 Speed Grade -5 Speed Grade Parameter Min
B port address hold time after clock Clock-to-output delay when using output registers Clock-to-output delay without output registers Minimum clock low time Minimum clock high time Minimum clear pulse width 1,250 1,250 144 203 715 2,803 1,437 1,437 165
Max
Min
233
Max
Min
280
Max
ps 986 3,866 ps ps ps ps ps
821 3,222 1,724 1,724 198
Note to Table 5-40:
FMAX of M-RAM Block obtained using the Quartus II software does not necessarily equal to 1/TMEGARC.
Stratix II Clock Timing Parameters
See Tables 5-41 through 5-65 for Stratix II clock timing parameters.
Table 5-41. Stratix II Clock Timing Parameters Symbol
tC I N tC O U T tP L L C I N tP L L C O U T
Parameter
Delay from clock pad to I/O input register Delay from clock pad to I/O output register Delay from PLL inclk pad to I/O input register Delay from PLL inclk pad to I/O output register
5-36 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
EP2S15 Clock Timing Parameters
Tables 5-42 though 5-45 show the maximum clock timing parameters for EP2S15 devices.
Table 5-42. EP2S15 Column Pins Regional Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.205 1.950 0.418 0.163
-4 Speed Grade
2.689 2.396 0.467 0.174
-5 Speed Grade
3.213 2.861 0.546 0.194
Unit
ns ns ns ns
Table 5-43. EP2S15 Column Pins Global Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.341 2.086 0.445 0.190
-4 Speed Grade
2.680 2.387 0.499 0.206
-5 Speed Grade
3.202 2.850 0.587 0.235
Unit
ns ns ns ns
Table 5-44. EP2S15 Row Pins Regional Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
1.941 1.940 0.158 0.157
-4 Speed Grade
2.403 2.402 0.169 0.168
-5 Speed Grade
2.869 2.868 0.190 0.189
Unit
ns ns ns ns
Table 5-45. EP2S15 Row Pins Global Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.103 2.102 0.205 0.204
-4 Speed Grade
2.406 2.405 0.223 0.222
-5 Speed Grade
2.873 2.872 0.256 0.255
Unit
ns ns ns ns
Altera Corporation March 2005
5-37 Stratix II Device Handbook, Volume 1
Timing Model
EP2S30 Clock Timing Parameters
Tables 5-46 through 5-49 show the maximum clock timing parameters for EP2S30 devices.
Table 5-46. EP2S30 Column Pins Regional Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.334 2.079 0.368 0.113
-4 Speed Grade
2.672 2.379 0.407 0.114
-5 Speed Grade
3.196 2.844 0.477 0.125
Unit
ns ns ns ns
Table 5-47. EP2S30 Column Pins Global Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.510 2.255 0.442 0.187
-4 Speed Grade
2.873 2.580 0.494 0.201
-5 Speed Grade
3.435 3.083 0.581 0.229
Unit
ns ns ns ns
Table 5-48. EP2S30 Row Pins Regional Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.026 2.025 0.080 0.079
-4 Speed Grade
2.316 2.315 0.077 0.076
-5 Speed Grade
2.767 2.766 0.080 0.079
Unit
ns ns ns ns
Table 5-49. EP2S30 Row Pins Global Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.234 2.233 0.170 0.169
-4 Speed Grade
2.554 2.553 0.183 0.182
-5 Speed Grade
3.054 3.053 0.208 0.207
Unit
ns ns ns ns
5-38 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
EP2S60 Clock Timing Parameters
Tables 5-50 through 5-53 show the maximum clock timing parameters for EP2S60 devices.
Table 5-50. EP2S60 Column Pins Regional Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.590 2.335 0.486 0.231
-4 Speed Grade
2.965 2.672 0.545 0.252
-5 Speed Grade
3.545 3.193 0.643 0.291
Unit
ns ns ns ns
Table 5-51. EP2S60 Column Pins Global Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.779 2.524 0.491 0.236
-4 Speed Grade
3.184 2.891 0.551 0.258
-5 Speed Grade
3.807 3.455 0.648 0.296
Unit
ns ns ns ns
Table 5-52. EP2S60 Row Pins Regional Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.312 2.311 0.217 0.216
-4 Speed Grade
2.646 2.645 0.235 0.234
-5 Speed Grade
3.163 3.162 0.271 0.270
Unit
ns ns ns ns
Table 5-53. EP2S60 Row Pins Global Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.533 2.532 0.247 0.246
-4 Speed Grade
2.900 2.899 0.270 0.269
-5 Speed Grade
3.467 3.466 0.312 0.311
Unit
ns ns ns ns
Altera Corporation March 2005
5-39 Stratix II Device Handbook, Volume 1
Timing Model
EP2S90 Clock Timing Parameters
Tables 5-54 through 5-57 show the maximum clock timing parameters for EP2S90 devices.
Table 5-54. EP2S90 Column Pins Regional Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.686 2.431 0.355 0.080
-4 Speed Grade
3.075 2.782 0.372 0.079
-5 Speed Grade
3.678 3.326 0.434 0.082
Unit
ns ns ns ns
Table 5-55. EP2S90 Column Pins Global Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.967 2.712 0.316 0.061
-4 Speed Grade
3.398 3.105 0.350 0.057
-5 Speed Grade
4.068 3.716 0.411 0.059
Unit
ns ns ns ns
Table 5-56. EP2S90 Row Pins Regional Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.390 2.389 0.055 0.054
-4 Speed Grade
2.737 2.736 0.048 0.047
-5 Speed Grade
3.271 3.270 0.048 0.047
Unit
ns ns ns ns
Table 5-57. EP2S90 Row Pins Global Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.701 2.700 0.059 0.058
-4 Speed Grade
3.093 3.092 0.053 0.052
-5 Speed Grade
3.699 3.698 0.053 0.052
Unit
ns ns ns ns
5-40 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
EP2S130 Clock Timing Parameters
Tables 5-58 through 5-61 show the maximum clock timing parameters for EP2S130 devices.
Table 5-58. EP2S130 Column Pins Regional Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.881 2.626 0.496 0.241
-4 Speed Grade
3.301 3.008 0.557 0.264
-5 Speed Grade
3.948 3.596 0.656 0.304
Unit
ns ns ns ns
Table 5-59. EP2S130 Column Pins Global Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
3.207 2.952 0.558 0.303
-4 Speed Grade
3.675 3.382 0.628 0.335
-5 Speed Grade
4.397 4.045 0.743 0.391
Unit
ns ns ns ns
Table 5-60. EP2S130 Row Pins Regional Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.628 2.627 0.252 0.251
-4 Speed Grade
3.008 3.007 0.277 0.276
-5 Speed Grade
3.596 3.595 0.321 0.320
Unit
ns ns ns ns
Table 5-61. EP2S130 Row Pins Global Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.941 2.940 0.297 0.296
-4 Speed Grade
3.368 3.367 0.326 0.325
-5 Speed Grade
4.028 4.027 0.379 0.378
Unit
ns ns ns ns
Altera Corporation March 2005
5-41 Stratix II Device Handbook, Volume 1
Timing Model
EP2S180 Clock Timing Parameters
Tables 5-62 through 5-65 show the maximum clock timing parameters for EP2S180 devices.
Table 5-62. EP2S180 Column Pins Regional Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
3.048 2.793 0.316 0.061
-4 Speed Grade
3.493 3.200 0.347 0.054
-5 Speed Grade
4.178 3.826 0.407 0.055
Unit
ns ns ns ns
Table 5-63. EP2S180 Column Pins Global Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
3.386 3.131 0.279 0.024
-4 Speed Grade
3.882 3.589 0.307 0.014
-5 Speed Grade
4.646 4.294 0.359 0.007
Unit
ns ns ns ns
Table 5-64. EP2S180 Row Pins Regional Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
2.737 2.736 0.032 0.031
-4 Speed Grade
3.134 3.133 0.022 0.021
-5 Speed Grade
3.746 3.745 0.015 0.014
Unit
ns ns ns ns
Table 5-65. EP2S180 Row Pins Global Clock Timing Parameters Parameter
tC I N tC O U T tP L L C I N tP L L C O U T
-3 Speed Grade
3.109 3.108 0.017 0.016
-4 Speed Grade
3.561 3.560 0.005 0.004
-5 Speed Grade
4.262 4.261 -0.005 -0.006
Unit
ns ns ns ns
5-42 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
IOE Programmable Delay
See Tables 5-66 and 5-67 for IOE programmable delay.
Table 5-66. Stratix II IOE Programmable Delay on Column Pins
Note (1)
Parameter
Input delay from pin to internal cells Input delay from pin to input register
Paths Affected
Pad to I/O dataout to logic array Pad to I/O input register
Number -3 Speed Grade -4 Speed Grade -5 Speed Grade of Max Min Max Min Max Unit Min Settings Offset Offset Offset Offset Offset Offset
8 64 2 2 0 0 0 0 2,883 3,277 500 483 0 0 0 0 3,315 3,768 575 556 0 0 0 0 3,978 4,521 690 667 ps ps ps ps
Delay from output I/O output register register to output pin to pad Output enable pin delay Notes to Table 5-66:
(1)
tX Z , tZ X
The incremental values for the settings are generally linear. For exact values of each setting, use the latest version of Quartus II software.
Table 5-67. Stratix II IOE Programmable Delay on Row Pins
Note (1)
Parameter
Input delay from pin to internal cells Input delay from pin to input register
Paths Affected
Pad to I/O dataout to logic array Pad to I/O input register
Number -3 Speed Grade -4 Speed Grade -5 Speed Grade of Min Max Min Max Min Max Unit Settings Offset Offset Offset Offset Offset Offset
8 64 2 2 0 0 0 0 2,883 3,277 500 483 0 0 0 0 3,315 3,768 575 556 0 0 0 0 3,978 4,521 690 667 ps ps ps ps
Delay from output I/O output register register to output pin to pad Output enable pin delay Note to Table 5-67:
(1)
tX Z , tZ X
The incremental values for the settings are generally linear. For exact values of each setting, use the latest version of Quartus II software.
Altera Corporation March 2005
5-43 Stratix II Device Handbook, Volume 1
Timing Model
Default Capacitive Loading of Different I/O Standards
See Table 5-68 for default capacitive loading of different I/O standards.
Table 5-68. Default Loading of Different I/O Standards for Stratix II I/O Standard
LVTTL LVCMOS 2.5 V 1.8 V 1.5 V PCI PCI-X SSTL-2 class I SSTL-2 class II SSTL-18 class I SSTL-18 class II 1.5-V HSTL class I 1.5-V HSTL class II 1.8-V HSTL class I 1.8-V HSTL class II Differential SSTL-2 class I Differential SSTL-2 class II Differential SSTL-18 class I Differential SSTL-18 class II 1.5-V differential HSTL class I 1.5-V differential HSTL class II 1.8-V differential HSTL class I 1.8-V differential HSTL class II LVDS HyperTransport LVPECL
Capacitive Load
0 0 0 0 0 10 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Unit
pF pF pF pF pF pF pF pF pF pF pF pF pF pF pF pF pF pF pF pF pF pF pF pF pF pF
5-44 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
I/O Delays
See Tables 5-69 through 5-73 for I/O delays.
Table 5-69. I/O Delay Parameters Symbol
tD I P tO P tP C O U T tP I
Parameter
Delay from I/O datain to output pad Delay from I/O output register to output pad Delay from input pad to I/O dataout to core Delay from input pad to I/O input register
Table 5-70. Stratix II I/O Input Delay for Column Pins (Part 1 of 2) I/O Standard
LVTTL tP I tP C O U T 2.5 V tP I tP C O U T 1.8 V tP I tP C O U T 1.5 V tP I tP C O U T LVCMOS tP I tP C O U T SSTL-2 class I tP I tP C O U T SSTL-2 class II tP I tP C O U T SSTL-18 class I tP I tP C O U T SSTL-18 class II tP I tP C O U T 1.5-V HSTL class I tP I tP C O U T
Parameter
-3 Speed Grade
870 757 857 744 1013 900 1083 970 870 757 465 352 465 352 545 432 545 432 640 527
-4 Speed Grade
999 870 984 855 1164 1035 1244 1115 999 870 533 404 533 404 625 496 625 496 735 606
-5 Speed Grade
1199 1044 1181 1026 1397 1242 1493 1338 1199 1044 640 485 640 485 751 596 751 596 882 727
Unit
ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps
Altera Corporation March 2005
5-45 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-70. Stratix II I/O Input Delay for Column Pins (Part 2 of 2) I/O Standard
1.5-V HSTL class II tP I tP C O U T 1.8-V HSTL class I tP I tP C O U T 1.8-V HSTL class II tP I tP C O U T PCI tP I tP C O U T PCI-X tP I tP C O U T Differential SSTL-2 class I tP I tP C O U T Differential SSTL-2 class II tP I tP C O U T Differential SSTL-18 class I tP I tP C O U T Differential SSTL-18 class II tP I tP C O U T 1.8-V differential HSTL class I tP I tP C O U T 1.8-V differential HSTL class II tP I tP C O U T 1.5-V differential HSTL class I tP I tP C O U T 1.5-V differential HSTL class II tP I tP C O U T
Parameter
-3 Speed Grade
640 527 545 432 545 432 861 748 861 748 465 352 465 352 545 432 545 432 545 432 545 432 640 527 640 527
-4 Speed Grade
735 606 625 496 625 496 989 860 989 860 533 404 533 404 625 496 625 496 625 496 625 496 735 606 735 606
-5 Speed Grade
882 727 751 596 751 596 1187 1032 1187 1032 640 485 640 485 751 596 751 596 751 596 751 596 882 727 882 727
Unit
ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps
5-46 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-71. Stratix II I/O Input Delay for Row Pins (Part 1 of 2) I/O Standard
LVTTL tP I tP C O U T 2.5 V tP I tP C O U T 1.8 V tP I tP C O U T 1.5 V tP I tP C O U T LVCMOS tP I tP C O U T SSTL-2 class I tP I tP C O U T SSTL-2 class II tP I tP C O U T SSTL-18 class I tP I tP C O U T SSTL-18 class II tP I tP C O U T 1.5-V HSTL class I tP I tP C O U T 1.5-V HSTL class II tP I tP C O U T 1.8-V HSTL class I tP I tP C O U T 1.8-V HSTL class II tP I tP C O U T Differential SSTL-2 class I tP I tP C O U T Differential SSTL-2 class II tP I tP C O U T Differential SSTL-18 class I tP I tP C O U T
Parameter
-3 Speed Grade
873 760 859 746 1013 900 1084 971 873 760 465 352 465 352 546 433 546 433 642 529 642 529 546 433 546 433 465 352 465 352 546 433
-4 Speed Grade
1002 873 986 857 1164 1035 1245 1116 1002 873 533 404 533 404 626 497 626 497 737 608 737 608 626 497 626 497 533 404 533 404 626 497
-5 Speed Grade
1203 1048 1184 1029 1397 1242 1494 1339 1203 1048 640 485 640 485 752 597 752 597 885 730 885 730 752 597 752 597 640 485 640 485 752 597
Unit
ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps
Altera Corporation March 2005
5-47 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-71. Stratix II I/O Input Delay for Row Pins (Part 2 of 2) I/O Standard
Differential SSTL-18 class II tP I tP C O U T 1.8-V differential HSTL class I tP I tP C O U T 1.8-V differential HSTL class II tP I tP C O U T 1.5-V differential HSTL class I tP I tP C O U T 1.5-V differential HSTL class II tP I tP C O U T LVDS tP I tP C O U T HyperTransport tP I tP C O U T
Parameter
-3 Speed Grade
546 433 546 433 546 433 642 529 642 529 534 421 534 421
-4 Speed Grade
626 497 626 497 626 497 737 608 737 608 613 484 613 484
-5 Speed Grade
752 597 752 597 752 597 885 730 885 730 735 580 735 580
Unit
ps ps ps ps ps ps ps ps ps ps ps ps ps ps
Table 5-72. Stratix II I/O Output Delay for Column Pins (Part 1 of 6) I/O Standard
LVTTL
Drive Parameter Strength
4 mA tO P tD I P 8 mA tO P tD I P 12 mA tO P tD I P 16 mA tO P tD I P 20 mA tO P tD I P 24 mA (1) tO P tD I P
-3 Speed Grade
1900 1920 1774 1794 1775 1795 1691 1711 1655 1675 1655 1675
-4 Speed Grade
2184 2207 2039 2062 2040 2063 1943 1966 1902 1925 1902 1925
-5 Speed Grade
2621 2649 2447 2475 2449 2477 2333 2361 2283 2311 2283 2311
Unit
ps ps ps ps ps ps ps ps ps ps ps ps
5-48 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-72. Stratix II I/O Output Delay for Column Pins (Part 2 of 6) I/O Standard
LVCMOS
Drive Parameter Strength
4 mA tO P tD I P 8 mA tO P tD I P 12 mA tO P tD I P 16 mA tO P tD I P 20 mA tO P tD I P 24 mA (1) tO P tD I P tO P tD I P 8 mA tO P tD I P 12 mA tO P tD I P 16 mA (1) tO P tD I P tO P tD I P 4 mA tO P tD I P 6 mA tO P tD I P 8 mA tO P tD I P 10 mA tO P tD I P 12 mA (1) tO P tD I P
-3 Speed Grade
1774 1794 1654 1674 1624 1644 1607 1627 1596 1616 1581 1601 1785 1805 1639 1659 1606 1626 1582 1602 2226 2246 1895 1915 1751 1771 1684 1704 1625 1645 1625 1645
-4 Speed Grade
2039 2062 1901 1924 1866 1889 1847 1870 1834 1857 1817 1840 2051 2074 1883 1906 1845 1868 1818 1841 2559 2582 2178 2201 2012 2035 1935 1958 1867 1890 1867 1890
-5 Speed Grade
2447 2475 2282 2310 2240 2268 2217 2245 2201 2229 2181 2209 2462 2490 2261 2289 2215 2243 2182 2210 3071 3099 2614 2642 2415 2443 2323 2351 2242 2270 2242 2270
Unit
ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps
2.5 V
4 mA
1.8 V
2 mA
Altera Corporation March 2005
5-49 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-72. Stratix II I/O Output Delay for Column Pins (Part 3 of 6) I/O Standard
1.5 V
Drive Parameter Strength
2 mA tO P tD I P 4 mA tO P tD I P 6 mA tO P tD I P 8 mA (1) tO P tD I P
-3 Speed Grade
2032 2052 1752 1772 1668 1688 1640 1660 1600 1620 1567 1587 1528 1548 1522 1542 1520 1540 1577 1597 1557 1577 1545 1565 1537 1557 1537 1557
-4 Speed Grade
2335 2358 2013 2036 1917 1940 1885 1908 1839 1862 1801 1824 1756 1779 1749 1772 1747 1770 1812 1835 1789 1812 1775 1798 1766 1789 1766 1789
-5 Speed Grade
2803 2831 2417 2445 2301 2329 2262 2290 2207 2235 2161 2189 2108 2136 2099 2127 2097 2125 2175 2203 2148 2176 2131 2159 2120 2148 2120 2148
Unit
ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps
SSTL-2 class I
8 mA
tO P tD I P
12 mA (1) SSTL-2 class II 16 mA
tO P tD I P tO P tD I P
20 mA
tO P tD I P
24 mA (1) SSTL-18 class I 4 mA
tO P tD I P tO P tD I P
6 mA
tO P tD I P
8 mA
tO P tD I P
10 mA
tO P tD I P
12 mA (1)
tO P tD I P
5-50 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-72. Stratix II I/O Output Delay for Column Pins (Part 4 of 6) I/O Standard
SSTL-18 class II
Drive Parameter Strength
8 mA tO P tD I P 16 mA tO P tD I P 18 mA tO P tD I P 20 mA (1) tO P tD I P tO P tD I P 6 mA tO P tD I P 8 mA tO P tD I P 10 mA tO P tD I P 12 mA (1) tO P tD I P tO P tD I P 18 mA tO P tD I P 20 mA (1) tO P tD I P
-3 Speed Grade
1519 1539 1512 1532 1517 1537 1515 1535 1562 1582 1545 1565 1536 1556 1531 1551 1531 1551 1507 1527 1509 1529 1507 1527
-4 Speed Grade
1745 1768 1737 1760 1743 1766 1741 1764 1795 1818 1775 1798 1765 1788 1759 1782 1759 1782 1732 1755 1734 1757 1732 1755
-5 Speed Grade
2095 2123 2086 2114 2092 2120 2090 2118 2155 2183 2131 2159 2119 2147 2112 2140 2112 2140 2079 2107 2081 2109 2079 2107
Unit
ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps
1.8-V HSTL class I
4 mA
1.8-V HSTL class II
16 mA
Altera Corporation March 2005
5-51 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-72. Stratix II I/O Output Delay for Column Pins (Part 5 of 6) I/O Standard
1.5-V HSTL class I
Drive Parameter Strength
4 mA tO P tD I P 6 mA tO P tD I P 8 mA tO P tD I P 10 mA tO P tD I P 12 mA (1) tO P tD I P tO P tD I P 18 mA tO P tD I P 20 mA tO P tD I P 24 mA (1) tO P tD I P tO P tD I P
-3 Speed Grade
1563 1583 1545 1565 1540 1560 1535 1555 1535 1555 1504 1524 1502 1522 1510 1530 246 266 1819 1839 1819 1839 1567 1587 1520 1540 1537 1557 1515 1535 1531 1551
-4 Speed Grade
1796 1819 1775 1798 1770 1793 1764 1787 1764 1787 1728 1751 1726 1749 1735 1758 282 305 2060 2083 2060 2083 1801 1824 1747 1770 1766 1789 1741 1764 1759 1782
-5 Speed Grade
2156 2184 2131 2159 2124 2152 2117 2145 2117 2145 2075 2103 2072 2100 2083 2111 339 367 2117 2145 2117 2145 2161 2189 2097 2125 2120 2148 2090 2118 2112 2140
Unit
ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps
1.5-V HSTL class II
16 mA
PCI
PCI-X
tO P tD I P
Differential SSTL-2 class I
tO P tD I P
Differential SSTL-2 class II
tO P tD I P
Differential SSTL-18 class I
tO P tD I P
Differential SSTL-18 class II
tO P tD I P
1.8-V differential HSTL class I
tO P tD I P
5-52 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-72. Stratix II I/O Output Delay for Column Pins (Part 6 of 6) I/O Standard
1.8-V differential HSTL class II
Drive Parameter Strength
tO P tD I P
-3 Speed Grade
1507 1527 1535 1555 246 266
-4 Speed Grade
1732 1755 1764 1787 282 305
-5 Speed Grade
2079 2107 2117 2145 339 367
Unit
ps ps ps ps ps ps
1.5-V differential HSTL class I
tO P tD I P
1.5-V differential HSTL class II
tO P tD I P
Note to Table 5-72:
(1) This is the default setting in Quartus II software.
Table 5-73. Stratix II I/O Output Delay for Row Pins (Part 1 of 3) I/O Standard
LVTTL
Drive Parameter Strength
4 mA tO P tD I P 8 mA tO P tD I P 12 mA tO P tD I P
-3 Speed Grade
1716 1716 1677 1677 1678 1678 1677 1677 1577 1577 1553 1553 1662 1662 1552 1552 1534 1534
-4 Speed Grade
1973 1973 1928 1928 1929 1929 1928 1928 1813 1813 1785 1785 1911 1911 1784 1784 1764 1764
-5 Speed Grade
2367 2367 2313 2313 2314 2314 2313 2313 2175 2175 2142 2142 2292 2292 2141 2141 2116 2116
Unit
ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps
LVCMOS
4 mA
tO P tD I P
8 mA
tO P tD I P
12 mA
tO P tD I P
2.5 V
4 mA
tO P tD I P
8 mA
tO P tD I P
12 mA
tO P tD I P
Altera Corporation March 2005
5-53 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-73. Stratix II I/O Output Delay for Row Pins (Part 2 of 3) I/O Standard
1.8 V
Drive Parameter Strength
2 mA tO P tD I P 4 mA tO P tD I P 6 mA tO P tD I P 8 mA tO P tD I P
-3 Speed Grade
1861 1861 1710 1710 1625 1625 1570 1570 1784 1784 1718 1718 1550 1550 1524 1524 1476 1476 307 307 1525 1525 1500 1500 1495 1495 307 307 307 307 1524 1524
-4 Speed Grade
2140 2140 1966 1966 1868 1868 1805 1805 2051 2051 1975 1975 1782 1782 1752 1752 1697 1697 353 353 1753 1753 1724 1724 1719 1719 353 353 353 353 1752 1752
-5 Speed Grade
2567 2567 2359 2359 2241 2241 2165 2165 2461 2461 2370 2370 2138 2138 2102 2102 2036 2036 423 423 2103 2103 2069 2069 2062 2062 423 423 423 423 2102 2102
Unit
ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps
1.5 V
2 mA
tO P tD I P
4 mA
tO P tD I P
SSTL-2 class I
8 mA
tO P tD I P
12 mA (1) SSTL-2 class II 16 mA
tO P tD I P tO P tD I P
20 mA
tO P tD I P
SSTL-18 class I
4 mA
tO P tD I P
6 mA
tO P tD I P
8 mA
tO P tD I P
10 mA
tO P tD I P
12 mA (1) Differential SSTL-2 class I
tO P tD I P tO P tD I P
5-54 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-73. Stratix II I/O Output Delay for Row Pins (Part 3 of 3) I/O Standard
Differential SSTL-2 class II
Drive Parameter Strength
tO P tD I P
-3 Speed Grade
307 307 307 307 2787 2787 2787 2787
-4 Speed Grade
353 353 353 353 3205 3205 3205 3205
-5 Speed Grade
423 423 423 423 3845 3845 3845 3845
Unit
ps ps ps ps ps ps ps ps
Differential SSTL-18 class I
tO P tD I P
LVDS
tO P tD I P
HyperTransport
tO P tD I P
Note to Table 5-73:
(1) This is the default setting in Quartus II software.
Maximum Input & Output Clock Rates
See Tables 5-74 through 5-77 for maximum I/O clock rates.
Table 5-74. Stratix II Maximum Input Clock Rate for Column Pins (Part 1 of 2) I/O Standard
LVTTL 2.5 V 1.8 V 1.5 V LVCMOS SSTL-2 class I SSTL-2 CLASS II SSTL-18 class I SSTL-18 class II 1.5-V HSTL class I 1.5-V HSTL class II 1.8-V HSTL class I 1.8-V HSTL class II PCI PCI-X Differential SSTL-2 class I
-3 Speed Grade
422 422 422 422 422 400 400 400 400 400 400 400 400 420 420 400
-4 Speed Grade
422 422 422 422 422 400 400 400 400 400 400 400 400 420 420 400
-5 Speed Grade
358 358 358 358 358 340 340 340 340 340 340 340 340 357 357 340
Unit
MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz
Altera Corporation March 2005
5-55 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-74. Stratix II Maximum Input Clock Rate for Column Pins (Part 2 of 2) I/O Standard
Differential SSTL-2 class II Differential SSTL-18 class I Differential SSTL-18 class II 1.8-V differential HSTL class I 1.8-V differential HSTL class II 1.5-V differential HSTL class I 1.5 V differential HSTL class II
-3 Speed Grade
400 400 400 400 400 400 400
-4 Speed Grade
400 400 400 400 400 400 400
-5 Speed Grade
340 340 340 340 340 340 340
Unit
MHz MHz MHz MHz MHz MHz MHz
Table 5-75. Stratix II Maximum Input Clock Rate for Row Pins (Part 1 of 2) I/O Standard
LVTTL 2.5 V 1.8 V 1.5 V LVCMOS SSTL -2 class I SSTL-2 class II SSTL-18 class I SSTL-18 class II 1.5-V HSTL class I 1.5-V HSTL class II 1.8-V HSTL class I 1.8-V HSTL class II PCI PCI-X Differential SSTL-2 class I Differential SSTL-2 class II Differential SSTL-18 class I Differential SSTL-18 class II 1.8-V differential HSTL class I 1.8-V differential HSTL class II 1.5-V differential HSTL class I 1.5-V differential HSTL class II
-3 Speed Grade
422 422 422 422 422 400 400 400 400 400 400 400 400 422 422 400 400 400 400 400 400 400 400
-4 Speed Grade
422 422 422 422 422 400 400 400 400 400 400 400 400 422 422 400 400 400 400 400 400 400 400
-5 Speed Grade
358 358 358 358 358 340 340 340 340 340 340 340 340 358 358 340 340 340 340 340 340 340 340
Unit
MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz
5-56 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-75. Stratix II Maximum Input Clock Rate for Row Pins (Part 2 of 2) I/O Standard
LVDS HyperTransport
-3 Speed Grade
500 520
-4 Speed Grade
500 520
-5 Speed Grade
425 442
Unit
MHz MHz
Table 5-76. Stratix II Maximum Output Clock Rate for Column Pins (Part 1 of 3) I/O Standard
LVTTL
Drive Strength
4 mA 8 mA 12 mA 16 mA 20 mA 24 mA (1)
-3 Speed Grade
350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350
-4 Speed Grade
350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350
-5 Speed Grade
297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297
Unit
MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz
LVCMOS
4 mA 8 mA 12 mA 16 mA 20 mA 24 mA (1)
2.5 V
4 mA 8 mA 12 mA 16 mA (1)
1.8 V
2 mA 4 mA 6 mA 8 mA 10 mA 12 mA (1)
1.5 V
2 mA 4 mA 6 mA 8 mA (1)
SSTL-2 class I
8 mA 12 mA (1)
Altera Corporation March 2005
5-57 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-76. Stratix II Maximum Output Clock Rate for Column Pins (Part 2 of 3) I/O Standard
SSTL-2 class II
Drive Strength
16 mA 20 mA 24 mA (1)
-3 Speed Grade
350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350
-4 Speed Grade
350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350
-5 Speed Grade
297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297
Unit
MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz
SSTL-18 class I
4 mA 6 mA 8 mA 10 mA 12 mA (1)
SSTL-18 class II
8 mA 16 mA 18 mA 20 mA (1)
1.8-V HSTL class I
4 mA 6 mA 8 mA 10 mA 12 mA (1)
1.8-V HSTL class II
16 mA 18 mA 20 mA (1)
1.5-V HSTL class I
4 mA 6 mA 8 mA 10 mA 12 mA (1)
1.5-V HSTL class II
16 mA 18 mA 20 mA 24 mA (1)
PCI PCI-X Differential SSTL-2 class I 8 mA 12 mA (1)
350 350
5-58 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-76. Stratix II Maximum Output Clock Rate for Column Pins (Part 3 of 3) I/O Standard
Differential SSTL-2 class II
Drive Strength
16 mA 20 mA 24 mA (1)
-3 Speed Grade
350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350
-4 Speed Grade
350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350
-5 Speed Grade
297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297
Unit
MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz
Differential SSTL-18 class I
4 mA 6 mA 8 mA 10 mA 12 mA (1)
Differential SSTL-18 class II
8 mA 16 mA 18 mA 20 mA (1)
1.8-V differential HSTL class I
4 mA 6 mA 8 mA 10 mA 12 mA (1)
1.8-V differential HSTL class II
16 mA 18 mA 20 mA (1)
1.5-V differential HSTL class I
4 mA 6 mA 8 mA 10 mA 12 mA (1)
1.5-V differential HSTL class II
16 mA 18 mA 20 mA 24 mA (1)
Note to Table 5-76:
(1) This is the1 default setting in Quartus II software.
Altera Corporation March 2005
5-59 Stratix II Device Handbook, Volume 1
Timing Model
Table 5-77. Stratix II Maximum Output Clock Rate for Row Pins (Part 1 of 2) I/O Standard
LVTTL
Drive Strength
4 mA 8 mA 12 mA
-3 Speed Grade
350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350
-4 Speed Grade
350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350
-5 Speed Grade
297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297 297
Unit
MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz MHz
LVCMOS
4 mA 8 mA 12 mA
2.5 V
4 mA 8 mA 12 mA
1.8 V
2 mA 4 mA 6 mA 8 mA
1.5 V
2 mA 4mA
SSTL-2 class I
8 mA 12 mA (1)
SSTL-2 class II
1 6mA 20 mA
SSTL-18 class I
4 mA 6 mA 8 mA 10 mA 12 mA (1)
Differential SSTL-2 class I
8 mA 12 mA (1)
Differential SSTL-2 class II
16 mA 20 mA (1)
Differential SSTL-18 class I
4 mA 6 mA 8 mA 10 mA 12 mA (1)
5-60 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-77. Stratix II Maximum Output Clock Rate for Row Pins (Part 2 of 2) I/O Standard
LVDS HyperTransport Note to Table 5-77:
(1) This is the default setting in the Quartus II software.
Drive Strength
-3 Speed Grade
500 520
-4 Speed Grade
500 520
-5 Speed Grade
425 442
Unit
MHz MHz
High-Speed I/O Specifications
Table 5-78 provides high-speed timing specifications definitions.
Table 5-78. High-Speed Timing Specifications & Definitions High-Speed Timing Specifications
tC fH S C L K tR I S E tF A L L Timing unit interval (TUI)
Definitions
High-speed receiver/transmitter input and output clock period. High-speed receiver/transmitter input and output clock frequency. Low-to-high transmission time. High-to-low transmission time. The timing budget allowed for skew, propagation delays, and data sampling window. (TUI = 1/(Receiver Input Clock Frequency x Multiplication Factor) = tC /w). Maximum/minimum LVDS data transfer rate (fH S D R = 1/TUI), non-DPA. Maximum/minimum LVDS data transfer rate (fH S D R D PA = 1/TUI), DPA. The timing difference between the fastest and slowest output edges, including tC O variation and clock skew. The clock is included in the TCCS measurement. The period of time during which the data must be valid in order to capture it correctly. The setup and hold times determine the ideal strobe position within the sampling window. Peak-to-peak input jitter on high-speed PLLs. Peak-to-peak output jitter on high-speed PLLs. Duty cycle on high-speed transmitter output clock. Lock time for high-speed transmitter and receiver PLLs.
fH S D R fH S D R D P A Channel-to-channel skew (TCCS)
Sampling window (SW)
Input jitter (peak-to-peak) Output jitter (peak-to-peak) tDUTY tL O C K
Altera Corporation March 2005
5-61 Stratix II Device Handbook, Volume 1
High-Speed I/O Specifications
Table 5-79 shows the high-speed I/O timing specifications for -3 speed grade Stratix II devices.
Table 5-79. High-Speed I/O Specifications for -3 Speed Grade (Part 1 of 2) Symbol Conditions Min
fH S C L K (Clock Frequency) W = 2 to 32 (LVDS, HyperTransport technology) (3) fH S C L K = f H S D R / W W = 1 (SERDES bypass, LVDS only) W = 1 (SERDES used, LVDS only) fH S D R (Data Rate) J = 4 to 10 (LVDS, HyperTransport technology) J = 2 (LVDS, HyperTransport technology) J = 1 (LVDS only) fH S D R D PA (DPA Data Rate) TCCS SW Input jitter tolerance (peak-to-peak) Output jitter tolerance (peak-to-peak) Output tR I S E Output tFA L L tDUTY tLOCK DPA run length DPA jitter tolerance (peak-to-peak) DPA minimum eye opening (peak-to-peak) DPA receiver latency J = 4 to 10 (LVDS, HyperTransport technology) All Differential Standards All Differential Standards 20 20 150 150 (4) (4) 150 330
Notes (1), (2) -3 Speed Grade Unit Typ Max
520 500 717 1,040 760 500 1,040 200 (5) (5) (5) (5) (5) (5) 6,400 (5) (5) (5) MHz MHz MHz Mbps Mbps Mbps Mbps ps ps ps ps ps ps % us UI UI UI Number of parallel CLK cycles
5-62 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-79. High-Speed I/O Specifications for -3 Speed Grade (Part 2 of 2) Symbol
DPA lock time Standard SPI-4 Parallel Rapid I/O
Notes (1), (2) -3 Speed Grade Unit
Conditions Min
Training Pattern 0000000000 1111111111 00001111 10010000 Misc 10101010 01010101 Transition Density 10% 25% 50% 100% 256 256 256 256 256
Typ
Max
Number of repetitions
Notes to Table 5-79:
(1) (2) (3) (4) When J = 4 to 10, the SERDES block is used. When J = 1 or 2, the SERDES block is bypassed. The input clock frequency and the W factor must satisfy the following FPLL VCO specification: 150 input clk frequency * W 1,040. The minimum specification is dependent on the clock source (FPLL, EPLL, clock pin, and so on) and the clock routing resource (global, regional, or local) utilized. The I/O differential buffer and input register do not have a minimum toggle rate. This specification is pending silicon characterization.
(5)
Table 5-80 shows the high-speed I/O timing specifications for -4 speed grade Stratix II devices.
Table 5-80. High-Speed I/O Specifications for -4 Speed Grade (Part 1 of 2) Symbol Conditions Min
fH S C L K (Clock Frequency) W = 2 to 32 (LVDS, HyperTransport technology) (3) fH S C L K = f H S D R / W W = 1 (SERDES bypass, LVDS only) W = 1 (SERDES used, LVDS only) fH S D R (Data Rate) J = 4 to 10 (LVDS, HyperTransport technology) J = 2 (LVDS, HyperTransport technology) J = 1 (LVDS only) fH S D R D PA (DPA Data Rate) TCCS SW J = 4 to 10 (LVDS, HyperTransport technology) All Differential Standards All Differential Standards 20 20 250 150 (4) (4) 150 330
Notes (1), (2) -4 Speed Grade Unit Typ Max
520 500 717 1,040 760 500 1,040 200 MHz MHz MHz Mbps Mbps Mbps Mbps ps ps
Altera Corporation March 2005
5-63 Stratix II Device Handbook, Volume 1
High-Speed I/O Specifications
Table 5-80. High-Speed I/O Specifications for -4 Speed Grade (Part 2 of 2) Symbol
Input jitter tolerance (peak-to-peak) Output jitter tolerance (peak-to-peak) Output tR I S E Output tFA L L tDUTY tLOCK DPA run length DPA jitter tolerance (peak-to-peak) DPA minimum eye opening (peak-to-peak) DPA receiver latency
Notes (1), (2) -4 Speed Grade Unit
Conditions Min Typ Max
(5) (5) (5) (5) (5) (5) 6,400 (5) (5) (5)
ps ps ps ps % us UI UI UI Number of parallel CLK cycles Number of repetitions
DPA lock time
Standard SPI-4 Parallel Rapid I/O
Training Pattern 0000000000 1111111111 00001111 10010000
Transition Density 10% 25% 50% 100% 256 256 256 256 256
Misc
10101010 01010101
Notes to Table 5-80:
(1) (2) (3) (4) When J = 4 to 10, the SERDES block is used. When J = 1 or 2, the SERDES block is bypassed. The input clock frequency and the W factor must satisfy the following FPLL VCO specification: 150 input clk frequency * W 1,040. The minimum specification is dependent on the clock source (FPLL, EPLL, clock pin, and so on) and the clock routing resource (global, regional, or local) utilized. The I/O differential buffer and input register do not have a minimum toggle rate. This specification is pending silicon characterization.
(5)
5-64 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-81 shows the high-speed I/O timing specifications for -5 speed grade Stratix II devices.
Table 5-81. High-Speed I/O Specifications for -5 Speed Grade Notes (1), (2) -5 Speed Grade Symbol Conditions Min
fH S C L K (Clock Frequency) W = 2 to 32 (LVDS, HyperTransport technology) (3) fH S C L K = f H S D R / W W = 1 (SERDES bypass, LVDS only) W = 1 (SERDES used, LVDS only) fH S D R (Data Rate) J = 4 to 10 (LVDS, HyperTransport technology) J = 2 (LVDS, HyperTransport technology) J = 1 (LVDS only) fH S D R D PA (DPA Data Rate) TCCS SW Input jitter tolerance (peak-to-peak) Output jitter tolerance (peak-to-peak) Output tR I S E Output tFA L L tDUTY tLOCK DPA run length DPA jitter tolerance (peak-to-peak) DPA minimum eye opening (peak-to-peak) DPA receiver latency J = 4 to 10 (LVDS, HyperTransport technology) All Differential Standards All Differential Standards 20 20 250 150 (4) (4) 150 440
Unit Typ Max
420 500 640 840 700 500 840 200 (5) (5) (5) (5) (5) (5) 6,400 (5) (5) (5) MHz MHz MHz Mbps Mbps Mbps Mbps ps ps ps ps ps ps % us UI UI UI Number of parallel CLK cycles
Altera Corporation March 2005
5-65 Stratix II Device Handbook, Volume 1
PLL Timing Specifications
Table 5-81. High-Speed I/O Specifications for -5 Speed Grade Notes (1), (2) -5 Speed Grade Symbol
DPA lock time Standard SPI-4 Parallel Rapid I/O
Conditions Min
Training Pattern 0000000000 1111111111 00001111 10010000 Misc 10101010 01010101 Transition Density 10% 25% 50% 100% 256 256 256 256 256
Unit Typ Max
Number of repetitions
Notes to Table 5-81:
(1) (2) (3) (4) When J = 4 to 10, the SERDES block is used. When J = 1 or 2, the SERDES block is bypassed. The input clock frequency and the W factor must satisfy the following FPLL VCO specification: 150 input clk frequency * W 1,040. The minimum specification is dependent on the clock source (FPLL, EPLL, clock pin, and so on) and the clock routing resource (global, regional, or local) utilized. The I/O differential buffer and input register do not have a minimum toggle rate. This specification is pending silicon characterization.
(5)
PLL Timing Specifications
Tables 5-82 and 5-83 describe the Stratix II PLL specifications when operating within the commercial junction temperature range from 0 to 85 C The industrial junction temperature range specifications will be available upon completion of the PLL characterization across the industrial junction temperature range from -40 to 100 C.
Table 5-82. Enhanced PLL Specifications (Part 1 of 2) Name
fIN fINPFD fINDUTY fEINDUTY tINJITTER tEINIJITTER tFCOMP fOUT
Description
Input clock frequency Maximum input frequency to the PFD Input clock duty cycle External feedback input clock duty cycle Input clock period jitter External feedback input period jitter External feedback compensation time Output frequency for internal global or regional clock
Min
1.5 1.5 40 40
Typ
Max
450 300 60 60 (1) (1) 10
Unit
MHz MHz % % ps (p-p) ps (p-p) ns MHz
1.5
500
5-66 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-82. Enhanced PLL Specifications (Part 2 of 2) Name
tSCANCLK fOUT_EXT tLOCK fCLBW fvco
Description
Scanclk frequency External PLL output frequency Time required for the PLL to lock from the time it is enabled PLL bandwidth PLL VCO operating range for -3 and -4 speed grade devices PLL VCO operating range for -5 speed grade devices
Min
Typ
Max
100
Unit
MHz MHz ms MHz MHz MHz ps
1.5 0.03 0.1 300 300 1
450 10 10 1,040 840 (1)
tLSKEW
Clock skew between two external clock outputs driven by two identically programmed PLL counters Static phase offset of the PLL itself Spread spectrum modulation frequency Guaranteed value Frequency range switch-over will function properly 1.5 100 0.5
tSPO fSS % spread fSWITCH.OVER
(1) 500 500 450
ps kHz % MHz
Note to Table 5-82:
(1) This specification is pending device characterization.
Table 5-83. Fast PLL Specifications Name
fIN fINDUTY tINJITTER fVCO Input frequency Input clock duty cycle Input clock jitter Upper VCO frequency range for -3 and -4 speed grades Upper VCO frequency range for -5 speed grades Lower VCO frequency range for -3 and -4 speed grades Lower VCO frequency range for -5 speed grades fOUT tOUTDUTY PLL output frequency to GCLK or RCLK PLL output frequency to LVDS or DPA clock Duty cycle for external clock output 300 300 150 150 9.375 150 45 50
Description
Min
20 40
Typ
Max
750 60 300 1,040 840 520 420 500 1,040 55
Unit
MHz % ps (p-p) MHz MHz
MHz MHz %
Altera Corporation March 2005
5-67 Stratix II Device Handbook, Volume 1
JTAG Timing Specifications
Table 5-83. Fast PLL Specifications Name
fEOUT tLOCK tCLBW tSCANCLK
Description
LVTTL external PLL output frequency LVDS external PLL output frequency Time required for the PLL to lock from the time it is enabled PLL bandwidth
Min
1.5 1.5
Typ
Max
166 717 1
Unit
MHz MHz ms MHz MHz
2
5
30 100
scanclk frequency
JTAG Timing Specifications
Figure 5-6 shows the timing requirements for the JTAG signals.
Figure 5-6. Stratix II JTAG Waveforms
TMS
TDI t JCP t JCH TCK tJPZX TDO tJSSU Signal to be Captured Signal to be Driven tJSH t JPCO t JPXZ t JCL t JPSU t JPH
tJSZX
tJSCO
tJSXZ
5-68 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
DC & Switching Characteristics
Table 5-84 shows the JTAG timing parameters and values for Stratix II devices.
Table 5-84. Stratix II JTAG Timing Parameters & Values Symbol
tJCP tJCH tJCL tJPSU tJPH tJPCO tJPZX tJPXZ tJSSU tJSH tJSCO tJSZX tJSXZ
Parameter
TCK clock period TCK clock high time TCK clock low time
JTAG port setup time JTAG port hold time JTAG port clock to output JTAG port high impedance to valid output JTAG port valid output to high impedance Capture register setup time Capture register hold time Update register clock to output Update register high impedance to valid output Update register valid output to high impedance
Min Max Unit
100 50 50 20 45 25 25 25 20 45 35 35 35 ns ns ns ns ns ns ns ns ns ns ns ns ns
Altera Corporation March 2005
5-69 Stratix II Device Handbook, Volume 1
JTAG Timing Specifications
5-70 Stratix II Device Handbook, Volume 1
Altera Corporation March 2005
6. Reference & Ordering Information
SII51006-2.0
Software
Stratix(R) II devices are supported by the Altera(R) Quartus(R) II design software, which provides a comprehensive environment for system-on-aprogrammable-chip (SOPC) design. The Quartus II software includes HDL and schematic design entry, compilation and logic synthesis, full simulation and advanced timing analysis, SignalTap(R) II logic analyzer, and device configuration. See the Quartus II Handbook for more information on the Quartus II software features. The Quartus II software supports the Windows XP/2000/NT/98, Sun Solaris, Linux Red Hat v7.1 and HP-UX operating systems. It also supports seamless integration with industry-leading EDA tools through the NativeLink(R) interface.
Device Pin-Outs Ordering Information
Device pin-outs for Stratix II devices are available on the Altera web site at (www.altera.com). Figure 6-1 describes the ordering codes for Stratix II devices. For more information on a specific package, refer to the Package Information for Stratix II Devices chapter in Volume 2 of the Stratix II Device Handbook.
Figure 6-1. Stratix II Device Packaging Ordering Information
EP2S Family Signature EP2S: Stratix II 90 F 1508 C 7 ES Optional Suffix Indicates specific device options or shipment method. ES: Engineering sample
Device Type 15 30 60 90 130 180 Speed Grade 3, 4, or 5, with 3 being the fastest
Operating Temperature C: Commercial temperature (tJ = 0 C to 85 C) I: Industrial temperature (tJ = -40 C to 100 C)
Package Type F: FineLine BGA H: Hybrid FineLine BGA
Pin Count Number of pins for a particular FineLine BGA package
Altera Corporation January 2005
6-1
Ordering Information
6-2 Stratix II Device Handbook, Volume 1
Altera Corporation January 2005


▲Up To Search▲   

 
Price & Availability of EP2S30XXX

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .